Preparation of a new chemical radiochromic film dosimeter

被引:17
|
作者
Akhavan, A [1 ]
Sohrabpour, M [1 ]
Sharifzadeh, M [1 ]
机构
[1] Atom Energy Org Iran, Gamma Irradiat Ctr, Tehran, Iran
关键词
dosimetry; gamma radiation; film dosimeters; radiochromic;
D O I
10.1016/S0969-806X(01)00610-7
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A new thin film dosimeter has been developed by using a chlorine-containing polymer matrix doped with malachite green methoxide as an indicator. Gamma irradiation of the film induces blue characteristic colour. The produced film with an average thickness of 0.05 mm has a linear response over the dose range of 1-60 kGy at the measured wavelength of 630 nm. The effects of temperature and relative humidity on the film response have been studied. The maximum absorbance of the film is found to be relatively stable over storage period of four weeks. (C) 2002 Published by Elsevier Science Ltd.
引用
收藏
页码:773 / 775
页数:3
相关论文
共 50 条
  • [1] Feasibility of a Reusable Radiochromic Dosimeter
    Newton, Joseph R.
    Recht, Maxwell
    Hauger, Joseph A.
    Segarra, Gabriel
    Inglett, Chase
    Romo, Pedro A.
    Adamovics, John
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [2] Radiochromic film dosimeter based on povidone-iodine for gamma dosimetric applications
    El-Shawadfy, El-Saeid R.
    Gafar, Sameh M.
    JOURNAL OF POLYMER ENGINEERING, 2025, 45 (04) : 344 - 350
  • [3] Commissioning a hobby cutting device for radiochromic film preparation
    Zolfaghari, Somayeh
    Francis, Kirby E.
    Kairn, Tanya
    Crowe, Scott B.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (02) : 449 - 453
  • [4] Commissioning a hobby cutting device for radiochromic film preparation
    Somayeh Zolfaghari
    Kirby E. Francis
    Tanya Kairn
    Scott B. Crowe
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 449 - 453
  • [5] Experimental Verification of a Monte Carlo Linear Accelerator Model Using a Radiochromic Film Stack Dosimeter
    McCaw, T.
    Culberson, W.
    DeWerd, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 313 - 313
  • [6] Radiochromic film containing poly(hexa-2,4-diynylene adipate) as a radiation dosimeter
    Soliman, Yasser S.
    Abdel-Fattah, Atef A.
    Alkhuraiji, Turki S.
    APPLIED RADIATION AND ISOTOPES, 2018, 141 : 80 - 87
  • [7] Radiochromic characteristics of liquid photonic crystal dosimeter
    He, Zhiwei
    Tang, Mingshuo
    Wang, Zhihao
    Wang, Yunlong
    CHEMICAL ENGINEERING JOURNAL, 2025, 511
  • [8] Portable radiochromic film readout system
    Krasinski, P.
    Makowski, D.
    Mukherjee, B.
    Simrock, S.
    Napieralski, A.
    MIXDES 2008: PROCEEDINGS OF THE 15TH INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2008, : 135 - +
  • [9] Developing a radiochromic dosimeter for dosimetry in blood irradiation chambers
    Farajzadeh, Ebrahim
    Sina, Sedigheh
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188 (188)
  • [10] A THICKNESS INDEPENDENT RADIOCHROMIC FILM DOSIMETRY SYSTEM
    RICKEY, JD
    HUMPHERYS, KC
    RADIATION PHYSICS AND CHEMISTRY, 1993, 42 (4-6): : 753 - 756