Backstepping stabilization of the linearized Saint-Venant-Exner model

被引:48
作者
Diagne, Ababacar [1 ]
Diagne, Mamadou [2 ]
Tang, Shuxia [3 ]
Krstic, Miroslav [3 ]
机构
[1] Uppsala Univ, Dept Informat Technol, Div Comp Sci, Box 337, S-75105 Uppsala, Sweden
[2] Univ Michigan, Dept Mech Engn, GG Brown Lab, 2350 Hayward, Ann Arbor, MI 48109 USA
[3] Univ Calif San Diego, Dept Mech & Aerosp Engn, La Jolla, CA 92093 USA
关键词
Backstepping; State feedback controller; Output feedback controller; Saint-Venant-Exner; Hyperbolic PDEs; HYPERBOLIC SYSTEM; PDES;
D O I
10.1016/j.automatica.2016.10.017
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Using backstepping design, exponential stabilization of the linearized Saint-Venant-Exner (SVE) model of water dynamics in a sediment-filled canal with arbitrary values of canal bottom slope, friction, porosity, and water-sediment interaction, is achieved. The linearized SVE model consists of two rightward convecting transport Partial Differential Equations (PDEs) and one leftward convecting transport PDE. A single boundary input control strategy with actuation located only at the downstream gate is employed. A full state feedback controller is designed which guarantees exponential stability of the desired setpoint of the resulting closed-loop system. Using the reconstruction of the distributed state through a backstepping observer, an output feedback controller is established, resulting in the exponential stability of the closed loop system at the desired setpoint. The proposed state and output feedback controllers can deal with both subcritical and supercritical flow regimes without any restrictive conditions. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:345 / 354
页数:10
相关论文
共 23 条
[21]  
Tang Y, 2014, IEEE DECIS CONTR P, P2840, DOI 10.1109/CDC.2014.7039825
[22]  
Xu C. Z., 1999, P 14 WORLD C IFAC BE, P147
[23]   Asymptotic Tracking Control of Uncertain Nonlinear Systems With Unknown Actuator Nonlinearity [J].
Zhang, Zhengqiang ;
Xu, Shengyuan ;
Zhang, Baoyong .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2014, 59 (05) :1336-1341