Flexible micro(bio)sensors for quantitative analysis of bioanalytes in a nanovolume of human lachrymal liquid

被引:29
作者
Andoralov, Viktor [1 ]
Shleev, Sergey [1 ]
Arnebrant, Thomas [1 ]
Ruzgas, Tautgirdas [1 ]
机构
[1] Malmo Univ, Fac Hlth & Soc, Dept Biomed Sci, S-20506 Malmo, Sweden
基金
瑞典研究理事会;
关键词
Flexible micro(bio)sensor; Nanovolume; Tears; Ascorbate; Dopamine; Glucose; TEAR GLUCOSE; ASCORBIC-ACID; URIC-ACID; TTF-TCNQ; BIOSENSOR; ELECTRODE; DOPAMINE; FLUID; ANTIOXIDANTS; BIOCHEMISTRY;
D O I
10.1007/s00216-013-6756-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A flexible electrochemical micro(bio)sensor has been designed for determination of several biological compounds, specifically, ascorbate, dopamine, and glucose, in human lachrymal liquid (tears). The microsensor for simultaneous determination of ascorbate and dopamine concentrations was based on a gold microwire modified with the tetrathiafulvalen-7,7,8,8-tetracyanoquinodimethane complex as a catalyst. To monitor glucose concentration in tears, glucose dehydrogenase was immobilized on a gold microwire modified with carbon nanotubes and an osmium redox polymer. A capillary microcell was constructed for sampling tears. The cell had a working volume of 60-100 nL with a sampling deviation of 6.7 %. To check if the microcell was properly filled with buffer or tear sample, a control electrode was introduced into the construction. The electrode was used to measure the electrical resistance of a fully filled nanovolume cell. The mechanical flexibility is one of the most important features of the prototype and allowed direct collection of tears with minimized risk of damage to the eye.
引用
收藏
页码:3871 / 3879
页数:9
相关论文
共 41 条
[1]   Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid [J].
Alexeev, VL ;
Das, S ;
Finegold, DN ;
Asher, SA .
CLINICAL CHEMISTRY, 2004, 50 (12) :2353-2360
[2]  
[Anonymous], 2010, Healthcare unwired: new business models delivering care anywhere, P1
[3]   Development of a carbon nanotube paste electrode osmium polymer-mediated biosensor for determination of glucose in alcoholic beverages [J].
Antiochia, Riccarda ;
Gorton, Lo .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2611-2617
[4]   Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers [J].
Baca, Justin T. ;
Taormina, Christopher R. ;
Feingold, Eleanor ;
Finegold, David N. ;
Grabowski, Joseph J. ;
Asher, Sanford A. .
CLINICAL CHEMISTRY, 2007, 53 (07) :1370-1372
[5]   Fluorescence sensors for monosaccharides based on the 6-methylquinolinium nucleus and boronic acid moiety: potential application to ophthalmic diagnostics [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
TALANTA, 2005, 65 (03) :762-768
[6]  
CARDOSI MF, 1990, DIABETES ANN, V5, P254
[7]  
Chen R, 1996, J CAPILLARY ELECTROP, V3, P243
[8]   Antioxidants in tears and plasma: Inter-relationships and effect of vitamin C supplementation [J].
Choy, CKM ;
Benzie, IFF ;
Cho, P .
CURRENT EYE RESEARCH, 2003, 27 (01) :55-60
[9]   Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment [J].
Chu, Ming Xing ;
Miyajima, Kumiko ;
Takahashi, Daishi ;
Arakawa, Takahiro ;
Sano, Kenji ;
Sawada, Shin-ichi ;
Kudo, Hiroyuki ;
Iwasaki, Yasuhiko ;
Akiyoshi, Kazunari ;
Mochizuki, Manabu ;
Mitsubayashi, Kohji .
TALANTA, 2011, 83 (03) :960-965
[10]   ANTIOXIDANT ENZYMES IN HUMAN TEARS [J].
CROUCH, RK ;
GOLETZ, P ;
SNYDER, A ;
COLES, WH .
JOURNAL OF OCULAR PHARMACOLOGY, 1991, 7 (03) :253-258