Studies on the Response of Double Sided Silicon Strip Detectors

被引:0
|
作者
Torresi, D. [1 ,2 ,3 ]
Stanko, D. [4 ]
Di Pietro, A. [1 ]
Figuera, P. [1 ]
Fisichella, M. [1 ,5 ]
Lattuada, M. [1 ,3 ]
Milin, M. [4 ]
Musumarra, A. [1 ,3 ]
Pellegriti, M. G. [1 ]
Scuderi, V. [1 ]
Strano, E. [1 ,3 ]
Zadro, M. [6 ]
机构
[1] Univ Padua, Dipartimento Fis & Astron, Padua, Italy
[2] Ctr Siliano Fis, Nucl Strutt Mat, Catania, Italy
[3] Univ Catania, Catania, Italy
[4] Univ Zagreb, Zagreb, Croatia
[5] Univ Messina, Messina, Italy
[6] Rudjer Boskovic Inst, Zagreb, Croatia
来源
关键词
DSSSD; efficiency;
D O I
10.1063/1.4764209
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this work is reported a study on the efficiency for full energy reconstruction of double sided silicon strip detectors. In order to investigate the effect of the electrode segmentation on the detector response signals, of both polarities for each side of the detectors was acquired at the same time. The efficiency for full energy reconstruction was studied as a function of the detector bias and the incident particle energy.
引用
收藏
页码:89 / 92
页数:4
相关论文
共 50 条
  • [21] Studies of double-sided silicon microstrip detectors
    Seidel, SC
    Bruner, NL
    Frautschi, MA
    Hoeferkamp, MR
    Patton, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01): : 128 - 136
  • [22] Heavy ion radiation damage in double-sided silicon strip detectors
    Livingston, K.
    Woods, P.J.
    Davinson, T.
    Shotter, A.C.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 370 (2-3): : 445 - 451
  • [23] Results on double-sided ac-coupled silicon strip detectors
    Batignani, G
    Bosisio, L
    Dellamarina, R
    Elmer, P
    Forti, F
    Giorgi, MA
    Rampino, G
    Rizzo, G
    Tritto, S
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1996, 109 (09): : 1319 - 1332
  • [24] Development of double-sided silicon strip detectors (DSSD) for a Compton telescope
    Takeda, Shin'ichiro
    Watanabe, Shin
    Tanaka, Takaaki
    Nakazawa, Kazuhiro
    Takahashi, Tadayuki
    Fukazawa, Yasushi
    Yasuda, Hajimu
    Tajima, Hiroyasu
    Kuroda, Yoshikatsu
    Onishi, Mitsunobu
    Genba, Kei
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 859 - 865
  • [25] Heavy ion radiation damage in double-sided silicon strip detectors
    Livingston, K
    Woods, PJ
    Davinson, T
    Shotter, AC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (2-3): : 445 - 451
  • [26] A high resolution beam telescope built with double sided silicon strip detectors
    Celano, L
    Creanza, D
    dePalma, M
    Maggi, G
    Fiore, L
    Paticchio, V
    Raso, G
    Selvaggi, G
    Silvestris, L
    Tempesta, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 381 (01): : 49 - 56
  • [27] Neutron beam profilometer on the base of double-sided silicon strip detectors
    Zamyatin, N., I
    Bystritsky, V. M.
    Kopach, Y. N.
    Aliyev, F. A.
    Grozdanov, D. N.
    Fedorov, N. A.
    Hramko, C.
    Ruskov, I. N.
    Skoy, V. R.
    Slepnev, V. M.
    Wang, D.
    Zubarev, E., V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 898 : 46 - 52
  • [28] FPGA-based readout for double-sided silicon strip detectors
    Becker, M.
    Brinkmann, K. -T.
    Koop, K.
    Schnell, R.
    Wuerschig, T.
    Zaunick, H. -G.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [29] A New Uniform Calibration Method for Double-Sided Silicon Strip Detectors
    Qiao, Rui
    Ye, Yanlin
    Wang, Jing
    Li, Zhihuan
    You, Haibo
    Yang, Zaihong
    Yang, Biao
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 596 - 601
  • [30] Study of the inter-strip gap effects on the response of Double Sided Silicon Strip Detectors using proton micro-beams
    Grassi, L.
    Forneris, J.
    Torresi, D.
    Acosta, L.
    Di Pietro, A.
    Figuera, P.
    Fisichella, M.
    Grilj, V.
    Jaksic, M.
    Lattuada, M.
    Mijatovic, T.
    Milin, M.
    Prepolec, L.
    Skukan, N.
    Soic, N.
    Tokic, V.
    Uroic, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 767 : 99 - 111