Fracture force, deflection at fracture, and toughness of repaired denture resin subjected to microwave polymerization or reinforced with wire or glass fiber

被引:48
作者
Polyzois, GL
Tarantili, PA
Frangou, MJ
Andreopoulos, AG
机构
[1] Univ Athens, Sch Dent, Dept Removable Prosthodont, Athens 11527, Greece
[2] Univ Athens, Sch Dent, Maxillofacial Prosthet Serv, Athens 11527, Greece
[3] Natl Tech Univ Athens, Dept Chem Engn, Athens, Greece
关键词
D O I
10.1067/mpr.2001.120069
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The ultimate goal of denture repair is to restore the denture's original strength and avoid further fracture. The best materials and methods for repair have not been conclusively determined. Purpose. This study investigated the fracture force, deflection at fracture, and toughness of a heat-polymerized denture base material repaired with heat-polymerized resin, autopolymerized resin alone, or autopolymerized resin with glass fiber or wire reinforcement. Material and methods. Eight groups were evaluated: 6 with autopolymerized resin repairs, 1 with heat-polymerized resin repairs, and a control group of intact specimens. The 6 autopolymerized resin groups included 1 group xvith no reinforcement, 1 treated with microwave irradiation after polymerization, 2 with monolayer or multilayer glass fiber reinforcement, and 2 with round or braided wire reinforcement. Each group consisted of 12 specimens. The experimental specimens were cut, and a 3-mm butt joint gap was repaired as indicated by the group assignment. A 3-point bending test was used to determine the fracture force, deflection at fracture, and toughness of the specimens. The data were analyzed with 1-way analysis of variance and the Tukey post-hoc test (alpha=.05). Results. The fracture force (28.4 to 73.4 N), deflection (1.6 to 3.8 mm), and toughness (0.02 to 0.13 J) values for all repaired groups were significantly lower than those for the control group (82.79 N, 4.4 mm, and 0.16 J, respectively), with one exception: the mean fracture force of specimens reinforced with round wire (102.9 N). Failure mode was always adhesive, meaning that fracture occurred between the denture base and repair resin. Conclusion. Among the repair treatments tested, the most effective was microwave-irradiated, autopolymerized resin reinforced with round wire or monolayer glass fiber ribbon.
引用
收藏
页码:613 / 619
页数:7
相关论文
共 29 条
[1]  
ANDERSON JN, 1976, APPLIED DENTAL MATER, P269
[2]  
Andreopoulos A G, 1991, Quintessence Int, V22, P703
[3]   REPAIR OF DENTURE BASE RESINS USING VISIBLE-LIGHT-CURED MATERIALS [J].
ANDREOPOULOS, AG ;
POLYZOIS, GL .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 72 (05) :462-468
[4]  
[Anonymous], 1997, QUINTESSENCE DENT TE
[5]   BENDING STRENGTH OF INTACT AND REPAIRED DENTURE BASE RESINS [J].
BERGE, M .
ACTA ODONTOLOGICA SCANDINAVICA, 1983, 41 (03) :187-191
[6]   REPAIR OF FRACTURED ACRYLIC RESIN [J].
BEYLI, MS ;
VONFRAUNHOFER, JA .
JOURNAL OF PROSTHETIC DENTISTRY, 1980, 44 (05) :497-503
[7]   Microwave polymerization of denture base materials. A comparative study [J].
Blagojevic, V ;
Murphy, VM .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (10) :804-808
[8]   DENTURE FRACTURE - A SURVEY [J].
DARBAR, UR ;
HUGGETT, R ;
HARRISON, A .
BRITISH DENTAL JOURNAL, 1994, 176 (09) :342-345
[9]   An evaluation of self-cured and visible light-cured denture base materials when used as a denture base repair material [J].
DarOdeh, NS ;
Harrison, A ;
AbuHammad, O .
JOURNAL OF ORAL REHABILITATION, 1997, 24 (10) :755-760
[10]  
GRAJOWER R, 1984, J ORAL REHABIL, V11, P237, DOI 10.1111/j.1365-2842.1984.tb00573.x