A robust linear regression based algorithm for automated evaluation of peptide identifications from shotgun proteomics by use of reversed-phase liquid chromatography retention time

被引:44
作者
Xu, Hua [1 ]
Yang, Lanhao [2 ]
Freitas, Michael A. [1 ]
机构
[1] Ohio State Univ, Ctr Comprehens Canc, Dept Mol Virol Immunol & Med Genet, Med Ctr, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Chem, Columbus, OH 43210 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1186/1471-2105-9-347
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Rejection of false positive peptide matches in database searches of shotgun proteomic experimental data is highly desirable. Several methods have been developed to use the peptide retention time as to refine and improve peptide identifications from database search algorithms. This report describes the implementation of an automated approach to reduce false positives and validate peptide matches. Results: A robust linear regression based algorithm was developed to automate the evaluation of peptide identifications obtained from shotgun proteomic experiments. The algorithm scores peptides based on their predicted and observed reversed-phase liquid chromatography retention times. The robust algorithm does not require internal or external peptide standards to train or calibrate the linear regression model used for peptide retention time prediction. The algorithm is generic and can be incorporated into any database search program to perform automated evaluation of the candidate peptide matches based on their retention times. It provides a statistical score for each peptide match based on its retention time. Conclusion: Analysis of peptide matches where the retention time score was included resulted in a significant reduction of false positive matches with little effect on the number of true positives. Overall higher sensitivities and specificities were achieved for database searches carried out with MassMatrix, Mascot and X!Tandem after implementation of the retention time based score algorithm.
引用
收藏
页数:15
相关论文
共 41 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]   Prediction of peptide retention at different HPLC conditions from multiple linear regression models [J].
Baczek, T ;
Wiczling, P ;
Marszall, M ;
Vander Heyden, Y ;
Kaliszan, R .
JOURNAL OF PROTEOME RESEARCH, 2005, 4 (02) :555-563
[3]   THE ISOLATION OF PEPTIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PREDICTED ELUTION POSITIONS [J].
BROWNE, CA ;
BENNETT, HPJ ;
SOLOMON, S .
ANALYTICAL BIOCHEMISTRY, 1982, 124 (01) :201-208
[4]   Open source system for analyzing, validating, and storing protein identification data [J].
Craig, R ;
Cortens, JP ;
Beavis, RC .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (06) :1234-1242
[5]   Target-decoy search strategy for increased confidence in large-scale protein identifications by mass spectrometry [J].
Elias, Joshua E. ;
Gygi, Steven P. .
NATURE METHODS, 2007, 4 (03) :207-214
[6]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[7]  
FOX J, 2002, R S PLUS COMP APPL R
[8]   Liquid chromatography at critical conditions: Comprehensive approach to sequence-dependent retention time prediction [J].
Gorshkov, Alexander V. ;
Tarasova, Irina A. ;
Evreinov, Victor V. ;
Savitski, Mikhail M. ;
Nielsen, Michael L. ;
Zubarev, Roman A. ;
Gorshkov, Mikhail V. .
ANALYTICAL CHEMISTRY, 2006, 78 (22) :7770-7777
[9]   PREDICTION OF PEPTIDE RETENTION TIMES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. DETERMINATION OF RETENTION COEFFICIENTS OF AMINO-ACID-RESIDUES OF MODEL SYNTHETIC PEPTIDES [J].
GUO, DC ;
MANT, CT ;
TANEJA, AK ;
PARKER, JMR ;
HODGES, RS .
JOURNAL OF CHROMATOGRAPHY, 1986, 359 :499-517
[10]   PREDICTION OF PEPTIDE RETENTION TIMES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. CORRELATION OF OBSERVED AND PREDICTED PEPTIDE RETENTION TIMES AND FACTORS INFLUENCING THE RETENTION TIMES OF PEPTIDES [J].
GUO, DC ;
MANT, CT ;
TANEJA, AK ;
HODGES, RS .
JOURNAL OF CHROMATOGRAPHY, 1986, 359 :519-532