Randomized clinical trial on single retainer all-ceramic resin-bonded fixed partial dentures: Influence of the bonding system after up to 55 months

被引:65
作者
Sasse, Martin [1 ]
Eschbach, Stephanie [1 ]
Kern, Matthias [1 ]
机构
[1] Univ Kiel, Dept Prosthodont Propaedeut & Dent Mat, Sch Dent, D-24105 Kiel, Germany
关键词
Resin bond; Randomized clinical trial; All-ceramic; Fixed dental prostheses; Single retainer; Bonding system; ZIRCONIA; SURVIVAL;
D O I
10.1016/j.jdent.2012.05.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the clinical outcome of all-ceramic resin-bonded fixed partial dentures (RBFPDs) with a cantilevered single-retainer design. Methods: Thirty anterior zirconia ceramic RBFPDs were inserted using either a phosphate monomer containing resin (Panavia 21 TC; N = 16) or an adhesive bonding system with a phosphoric acid acrylate primer (Multilink-Automix with Metal/Zirconia primer; N = 14). Results: During a mean observation time of 41.7 months one debonding occurred in each group. Both RBFPDs could be rebonded successfully resulting in a three-year survival rate of 100%. Conclusion: Independent of the bonding system cantilevered zirconia ceramic RBFPDs showed promising results during the first three years. Clinical significance: Single-retainer zirconia ceramic RBFPD present an alternative treatment option offering good aesthetics, a minimal invasive preparation, a high biocompatibility and can even be used to treat juvenile patients who do not yet come into consideration for implant placement. No significant influence of the bonding system used was detected so far. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:783 / 786
页数:4
相关论文
共 18 条
[1]   Zirconia ceramic inlay-retained fixed dental prostheses - first clinical results with a new design [J].
Abou Tara, Milia ;
Eschbach, Stephanie ;
Wolfart, Stefan ;
Kern, Matthias .
JOURNAL OF DENTISTRY, 2011, 39 (03) :208-211
[2]   Failure modes of Y-TZP crowns at different cusp inclines [J].
Bonfante, Estevam A. ;
Sailer, Irena ;
Silva, Nelson R. F. A. ;
Thompson, Van P. ;
Rekow, E. Dianne ;
Coelho, Paulo G. .
JOURNAL OF DENTISTRY, 2010, 38 (09) :707-712
[3]   Fatigue and damage accumulation of veneer porcelain pressed on Y-TZP [J].
Bonfante, Estevam A. ;
Coelho, Paulo G. ;
Guess, Petra C. ;
Thompson, Van P. ;
Silva, Nelson R. F. A. .
JOURNAL OF DENTISTRY, 2010, 38 (04) :318-324
[4]   A retrospective clinical evaluation of two-unit cantilevered resin-bonded fixed partial dentures [J].
Botelho, MG ;
Leung, KCM ;
Ng, H ;
Chan, K .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2006, 137 (06) :783-788
[5]   State of the art of zirconia for dental applications [J].
Denry, Isabelle ;
Kelly, J. Robert .
DENTAL MATERIALS, 2008, 24 (03) :299-307
[6]   The clinical performance of cantilevered resin-bonded bridgework [J].
Hussey, DL ;
Linden, GJ .
JOURNAL OF DENTISTRY, 1996, 24 (04) :251-256
[7]   NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS [J].
KAPLAN, EL ;
MEIER, P .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) :457-481
[8]  
Kern M, 2005, QUINTESSENCE INT, V36, P141
[9]   Surface Conditioning Influences Zirconia Ceramic Bonding [J].
Kern, M. ;
Barloi, A. ;
Yang, B. .
JOURNAL OF DENTAL RESEARCH, 2009, 88 (09) :817-822
[10]   Ten-year Survival of Anterior All-ceramic Resin-bonded Fixed Dental Prostheses [J].
Kern, Matthias ;
Sasse, Martin .
JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (05) :407-410