Assessment of capillary fluid shifts during orthostatic stress in normal subjects and subjects with orthostatic intolerance

被引:45
作者
Brown, CM [1 ]
Hainsworth, R [1 ]
机构
[1] Univ Leeds, Inst Cardiovasc Res, Leeds LS2 9JT, W Yorkshire, England
关键词
plasma volume; orthostasis; impedance plethysmography;
D O I
10.1007/BF02311762
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Orthostatic stress causes, in addition to venous pooling, a loss of plasma fluid from capillaries to the dependent tissues. The rate of this loss may be one of the factors determining orthostatic tolerance. In this study we assessed the use of a multichannel impedance plethysmograph for determining changes in volume in the calf, thigh, and abdominal segments, in asymptomatic volunteers and in patients shown to have poor tolerance to orthostatic stress. Impedance plethysmography showed, for leg segments, that following head-up tilt there was an initial rapid change in volume followed after 2 to 4 minutes by an almost linear change. Results from the abdominal segment were more variable. The rate of change of leg (thigh + calf) volume was significantly correlated with the estimated loss of plasma volume derived from the changes in the concentration of plasma protein, using Evans Blue dye as the marker. Comparison of results of leg filtration rates between patients and volunteers indicated that some of the patients had abnormally high filtration rates and suggests that impedance plethysmography may have a role in assessing the possible reasons for orthostatic intolerance.
引用
收藏
页码:69 / 73
页数:5
相关论文
共 23 条
[1]  
el-Bedawi K M, 1994, Clin Auton Res, V4, P41
[2]   Salt supplement increases plasma volume and orthostatic tolerance in patients with unexplained syncope [J].
ElSayed, H ;
Hainsworth, R .
HEART, 1996, 75 (02) :134-140
[3]   RELATIONSHIP BETWEEN PLASMA-VOLUME, CAROTID BARORECEPTOR SENSITIVITY AND ORTHOSTATIC TOLERANCE [J].
ELSAYED, H ;
HAINSWORTH, R .
CLINICAL SCIENCE, 1995, 88 (04) :463-470
[4]  
ELSAYED H, 1995, CLIN LAB HAEMATOL, V17, P189
[5]   EFFECTS OF POSTURE ON PLASMA VOLUME AND SOME BLOOD CONSTITUENTS [J].
FAWCETT, JK ;
WYNN, V .
JOURNAL OF CLINICAL PATHOLOGY, 1960, 13 (04) :304-310
[6]   A REASSESSMENT OF MERCURY IN SILASTIC STRAIN-GAUGE PLETHYSMOGRAPHY FOR MICROVASCULAR PERMEABILITY ASSESSMENT IN MAN [J].
GAMBLE, J ;
GARTSIDE, IB ;
CHRIST, F .
JOURNAL OF PHYSIOLOGY-LONDON, 1993, 464 :407-422
[7]   PLASMA-VOLUME CHANGES WITH MOVEMENT TO SUPINE AND STANDING POSITIONS [J].
HAGAN, RD ;
DIAZ, FJ ;
HORVATH, SM .
JOURNAL OF APPLIED PHYSIOLOGY, 1978, 45 (03) :414-418
[8]   CARDIOVASCULAR-RESPONSES TO UPRIGHT TILTING IN HEALTHY-SUBJECTS [J].
HAINSWORTH, R ;
ALSHAMMA, YMH .
CLINICAL SCIENCE, 1988, 74 (01) :17-22
[9]  
Hainsworth R, 1994, Clin Auton Res, V4, P239, DOI 10.1007/BF01827428
[10]  
HAINSWORTH R, 1985, HYPOTENSIVE ANAESTHE, P22