Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring

被引:3
作者
Ugi, Satoshi [1 ]
Maegawa, Hiroshi [1 ]
Morino, Katsutaro [1 ]
Nishio, Yoshihiko [2 ]
Sato, Toshiyuki [3 ]
Okada, Seiki [3 ]
Kikkawa, Yasuo [3 ]
Watanabe, Toshihiro [3 ]
Nakajima, Hiromu [4 ]
Kashiwagi, Atsunori [5 ]
机构
[1] Shiga Univ Med Sci, Dept Med, Otsu, Shiga 5202192, Japan
[2] Kagoshima Univ, Grad Sch Med & Dent Sci, Dept Diabet & Endocrine Med, Kagoshima, Japan
[3] Sysmex Corp, Cent Res Labs, Kobe, Hyogo, Japan
[4] Osaka Med Ctr Canc & Cardiovasc Dis, Dept Clin Lab, Osaka, Japan
[5] Kusatsu Gen Hosp, Dept Med, Kusatsu, Japan
关键词
Continuous glucose monitoring; Extracellular fluid; Glucose area under the curve; Glucose monitoring; Postprandial glycemic excursion; EXTRACTION TECHNOLOGY EVALUATION; DIABETES-MELLITUS; PROGRESSION;
D O I
10.4093/dmj.2016.40.4.326
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Management of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET) for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM) by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration. Methods: Twenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels. Results: AUC predicted by MIET correlated well with that measured by CGM (r=0.93). Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%+/- 10.2% for 2 hours and 11.1%+/- 7.9% for 4 hours), indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours. Conclusion: Our system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.
引用
收藏
页码:326 / 333
页数:8
相关论文
共 13 条
[1]  
[Anonymous], 2000, CLIN DIABETES
[2]   Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites [J].
Ellison, JM ;
Stegmann, JM ;
Colner, SL ;
Michael, RH ;
Sharma, MK ;
Ervin, KR ;
Horwitz, DL .
DIABETES CARE, 2002, 25 (06) :961-964
[3]   Acarbose slows progression of intima-media thickness of the carotid arteries in subjects with impaired glucose tolerance [J].
Hanefeld, M ;
Chiasson, JL ;
Koehler, C ;
Henkel, E ;
Schaper, F ;
Temelkova-Kurktschiev, T .
STROKE, 2004, 35 (05) :1073-1078
[4]   Voglibose for prevention of type 2 diabetes mellitus: a randomised, double-blind trial in Japanese individuals with impaired glucose tolerance [J].
Kawamori, Ryuzo ;
Tajima, Naoko ;
Iwamoto, Yasuhiko ;
Kashiwagi, Atsunori ;
Shimamoto, Kazuaki ;
Koku, Kohei .
LANCET, 2009, 373 (9675) :1607-1614
[5]   Evaluation of Postprandial Glucose Excursion Using a Novel Minimally Invasive Glucose Area-Under-the-Curve Monitoring System [J].
Kuranuki, Sachi ;
Sato, Toshiyuki ;
Okada, Seiki ;
Hosoya, Samiko ;
Seko, Akinobu ;
Sugihara, Kaya ;
Nakamura, Teiji .
JOURNAL OF HEALTHCARE ENGINEERING, 2013, 4 (04) :529-540
[6]   INTENSIVE INSULIN THERAPY PREVENTS THE PROGRESSION OF DIABETIC MICROVASCULAR COMPLICATIONS IN JAPANESE PATIENTS WITH NON-INSULIN-DEPENDENT DIABETES-MELLITUS - A RANDOMIZED PROSPECTIVE 6-YEAR STUDY [J].
OHKUBO, Y ;
KISHIKAWA, H ;
ARAKI, E ;
MIYATA, T ;
ISAMI, S ;
MOTOYOSHI, S ;
KOJIMA, Y ;
FURUYOSHI, N ;
SHICHIRI, M .
DIABETES RESEARCH AND CLINICAL PRACTICE, 1995, 28 (02) :103-117
[7]  
Sakaguchi Kazuhiko, 2013, J Diabetes Sci Technol, V7, P678
[8]   A Minimally Invasive System for Glucose Area Under the Curve Measurement Using Interstitial Fluid Extraction Technology: Evaluation of the Accuracy and Usefulness with Oral Glucose Tolerance Tests in Subjects With and Without Diabetes [J].
Sakaguchi, Kazuhiko ;
Hirota, Yushi ;
Hashimoto, Naoko ;
Ogawa, Wataru ;
Sato, Toshiyuki ;
Okada, Seiki ;
Hagino, Kei ;
Asakura, Yoshihiro ;
Kikkawa, Yasuo ;
Kojima, Junko ;
Maekawa, Yasunori ;
Nakajima, Hiromu .
DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (06) :485-491
[9]   Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients [J].
Sakamoto, Kenya ;
Kubo, Fumiyo ;
Yoshiuchi, Kazutomi ;
Ono, Akemi ;
Sato, Toshiyuki ;
Tomita, Koji ;
Sakaguchi, Kazuhiko ;
Matsuhisa, Munehide ;
Kaneto, Hideaki ;
Maegawa, Hiroshi ;
Nakajima, Hiromu ;
Kashiwagi, Atsunori ;
Kosugi, Keisuke .
JOURNAL OF DIABETES INVESTIGATION, 2013, 4 (06) :552-559
[10]   Measurement of Glucose Area Under the Curve Using Minimally Invasive Interstitial Fluid Extraction Technology: Evaluation of Glucose Monitoring Concepts Without Blood Sampling [J].
Sato, Toshiyuki ;
Okada, Seiki ;
Hagino, Kei ;
Asakura, Yoshihiro ;
Kikkawa, Yasuo ;
Kojima, Junko ;
Watanabe, Toshihiro ;
Maekawa, Yasunori ;
Isobe, Kazuki ;
Koike, Reona ;
Nakajima, Hiromu ;
Asano, Kaoru .
DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (12) :1194-1200