Need for background suppression in contrast-enhanced peripheral magnetic resonance angiography

被引:12
作者
Leiner, T
de Weert, TT
Nijenhuis, RJ
Vasbinder, GBC
Kessels, AGH
Ho, KYJAM
van Engelshoven, JMA
机构
[1] Maastricht Univ Hosp, Cardiovasc Res Inst Maastricht, Dept Radiol, NL-6229 HX Maastricht, Netherlands
[2] Maastricht Univ Hosp, Dept Clin Epidemiol & Med Technol Assessment, NL-6229 HX Maastricht, Netherlands
关键词
contrast-enhanced MR angiography; magnetic resonance vascular studies; magnetic resonance; fat suppression; MR technique; peripheral arteries; peripheral arterial occlusive disease;
D O I
10.1002/jmri.10012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine if background suppression is beneficial for peripheral magnetic resonance angiography (pMRA), nonsubtracted, subtracted, and fat-saturated contrast-enhanced (CE) pMRA were compared in 10 patients with peripheral arterial disease. Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs), as well as venous enhancement and subjective interpretability, were determined in a station-by-station fashion for each technique. In three patients X-ray angiography was available as a standard of reference. SNRs and CNRs were significantly higher for fat-saturated vs. the other two techniques (P = 0.005). Subjective interpretability was best for subtracted data sets in the lower-leg station. In the iliac station, fat-saturated data sets were considered to have significantly lower interpretability than subtracted data sets. Venous enhancement occurred significantly more often in the lower-leg station with the fat-saturated technique. The value of subtraction depends on the hardware one has available and is a useful tool if dedicated surface coils are used. Background suppression by means of magnitude subtraction leads to the best lower-leg image interpretability. Care must be taken to avoid venous enhancement in the lower-leg station when using fat saturation. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:724 / 733
页数:10
相关论文
共 16 条
  • [1] Busch HP, 1999, ROFO-FORTSCHR RONTG, V170, P275
  • [2] Fat suppression in MR imaging: Techniques and pitfalls
    Delfaut, EM
    Beltran, J
    Johnson, G
    Rousseau, J
    Marchandise, X
    Cotten, A
    [J]. RADIOGRAPHICS, 1999, 19 (02) : 373 - 382
  • [3] HAACKE EM, 1999, MAGNETIC RESONANCE I, P875
  • [4] Partial fat-saturated contrast-enhanced three-dimensional MR angiography compared with non-fat-saturated and conventional fat-saturated MR angiography
    Hilfiker, PR
    Herfkens, RJ
    Heiss, SG
    Alley, MT
    Fleischmann, D
    Pelc, NJ
    [J]. RADIOLOGY, 2000, 216 (01) : 298 - 303
  • [5] Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography
    Ho, KYJAM
    Leiner, T
    de Haan, MW
    Kessels, AGH
    Kitslaar, PJEHM
    van Engelshoven, JMA
    [J]. RADIOLOGY, 1998, 206 (03) : 683 - 692
  • [6] Ho VB, 1999, JMRI-J MAGN RESON IM, V10, P376, DOI 10.1002/(SICI)1522-2586(199909)10:3<376::AID-JMRI20>3.0.CO
  • [7] 2-U
  • [8] Optimization of chemical shift selective suppression of fat
    Kuroda, K
    Oshio, K
    Mulkern, RV
    Jolesz, FA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (04) : 505 - 510
  • [9] Leiner T, 2000, JMRI-J MAGN RESON IM, V11, P368, DOI 10.1002/(SICI)1522-2586(200004)11:4<368::AID-JMRI4>3.0.CO
  • [10] 2-5