Enhancement of a heat sink performance using a partial shield and/or a guide plate

被引:8
作者
Elsayed, Mohamed L. [1 ,2 ]
Mesalhy, Osama [1 ,2 ]
Mohammed, Ramy H. [1 ,2 ]
Kizito, John P. [3 ]
Leland, Quinn H. [4 ]
Chow, Louis C. [1 ]
机构
[1] Univ Cent Florida, Dept Mech & Aerosp Engn, Orlando, FL 32816 USA
[2] Zagazig Univ, Dept Mech Power Engn, Zagazig 44519, Egypt
[3] North Carolina Agr & Technol State Univ, Dept Mech Engn, Greensboro, NC USA
[4] Air Force Res Lab, Aerosp Syst Directorate, Power & Control Div, Wright Patterson AFB, OH USA
关键词
Heat sink; Hydraulic/thermal performance; Partial shield; Guide plate; FLOW BYPASS; THERMAL DESIGN; FIN; OPTIMIZATION;
D O I
10.1016/j.ijheatmasstransfer.2019.01.096
中图分类号
O414.1 [热力学];
学科分类号
摘要
The potential of using a full shield or partial shield with a guide plate to control the bypass cooling air flowing above a heat sink is numerically modeled using two different scenarios of inlet conditions - fixed mass flow rate and specified fan curve. Excellent agreement is observed when the simulation results are compared with available experimental data in the literature. Under the first inlet condition, the Nusselt numbers associated with the full shield installation are significantly higher than those without a shield, but with a significant pressure drop penalty. Friction factor increases with partial shield height till it reaches a maximum value with the full-shield configuration. Using an inclined guide plate with a partial shield alters the flow direction, forcing the air to impinge on the heat sink. This adds an extra cooling effect but without causing a considerable increase in the friction factor. In the case of fixed inlet mass flow rate, most of the partial shield and guide plate cases show the lowest pressure drop when the ratio of the partial shield height to the total bypass height H-s/H-BP is between 0.35 and 0.5. The case with an inclination angle of theta(P) = 15 degrees has the highest thermal performance and the highest pressure drop. Correlations for the average Nusselt number and friction factor are developed to include the effect of Reynolds number, shield height, bypass height and guide plate inclination angle. For the second inlet condition, the test cases are repeated using a selected fan characteristic curve as an alternate to the fixed mass flow rate condition. The specified fan curve case shows that a short partial shield with a slightly inclined guide plate has a better thermal performance than the full shield case. Furthermore, using a guide plate only with a small inclination angle has a superior thermal performance. Changing the position of the guide plate is investigated as well and the optimal location is obtained. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:948 / 958
页数:11
相关论文
共 31 条
[1]   Optimization of thermal design of heat sinks: A review [J].
Ahmed, Hamdi E. ;
Salman, B. H. ;
Kherbeet, A. Sh. ;
Ahmed, M. I. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 118 :129-153
[2]   Optimization of thermal design of ribbed flat-plate fin heat sink [J].
Ahmed, Hamdi E. .
APPLIED THERMAL ENGINEERING, 2016, 102 :1422-1432
[3]  
ANSYS Inc, 2016, ANSYS Fluent User's Guide Release 17.2
[4]   Characterization of longitudinal fin heat sink thermal performance and flow bypass effects through CFD methods [J].
Barrett, AV ;
Obinelo, IF .
THIRTEENTH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 1997, 1997, :158-164
[5]   Finned metal foam heat sinks for electronics cooling in forced convection [J].
Bhattacharya, A ;
Mahajan, RL .
JOURNAL OF ELECTRONIC PACKAGING, 2002, 124 (03) :155-163
[6]   Investigation of heat transfer characteristics in plate-fin heat sink [J].
Chen, Han-Taw ;
Lai, Shih-Ting ;
Haung, Li-Ying .
APPLIED THERMAL ENGINEERING, 2013, 50 (01) :352-360
[7]   Experimental and numerical investigations of heat transfer and flow characteristics of cross-cut heat sinks [J].
Chingulpitak, Sakkarin ;
Chimres, Nares ;
Nilpueng, Kitti ;
Wongwises, Somchai .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 102 :142-153
[8]   Optimization of plate fin heat sinks using entropy generation minimization [J].
Culham, JR ;
Muzychka, YS .
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2001, 24 (02) :159-165
[9]   Experimental study of heat transfer and fluid flow in longitudinal rectangular-fin array located in different orientations in fluid flow [J].
El-Sayed, SA ;
Mohamed, SM ;
Abdel-Latif, AA ;
Abouda, AHE .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2004, 29 (01) :113-128
[10]   Effect of a Slotted Shield on Thermal and Hydraulic Performance of a Heat Sink [J].
Elsayed, Mohamed L. ;
Mesalhy, Osama .
JOURNAL OF ELECTRONIC PACKAGING, 2015, 137 (01)