Phakic Iris-Fixated Intraocular Lens Placement in the Anterior Chamber: Effects on Aqueous Flow

被引:28
|
作者
Repetto, Rodolfo [1 ]
Pralits, Jan O. [1 ]
Siggers, Jennifer H. [2 ]
Soleri, Paolo [3 ]
机构
[1] Univ Genoa, Dept Civil Chem & Environm Engn, Genoa, Italy
[2] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London SW7 2AZ, England
[3] Ophtec BV, Groningen, Netherlands
关键词
aqueous flow; shear stress; intraocular pressure; CORNEAL ENDOTHELIAL-CELLS; LASER IRIDOTOMY; HUMAN EYE; SHEAR-STRESS; HUMOR; MODEL; SPINDLE; TISSUES;
D O I
10.1167/iovs.14-16118
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. METHODS. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. RESULTS. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. CONCLUSIONS. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.
引用
收藏
页码:3061 / 3068
页数:8
相关论文
共 48 条
  • [1] Aqueous flow in the presence of a perforated iris-fixated intraocular lens
    Khongar, Peyman Davvalo
    Pralits, Jan O.
    Soleri, Paolo
    Repetto, Rodolfo
    MECCANICA, 2017, 52 (03) : 577 - 586
  • [2] Aqueous flow in the presence of a perforated iris-fixated intraocular lens
    Peyman Davvalo Khongar
    Jan O. Pralits
    Paolo Soleri
    Rodolfo Repetto
    Meccanica, 2017, 52 : 577 - 586
  • [3] Flow in the anterior chamber of the eye with an implanted iris-fixated artificial lens
    Tweedy, Jennifer H.
    Pralits, Jan O.
    Repetto, Rodolfo
    Soleri, Paolo
    MATHEMATICAL MEDICINE AND BIOLOGY-A JOURNAL OF THE IMA, 2018, 35 (03): : 363 - 385
  • [4] A Mathematical Model of Corneal Metabolism in the Presence of an Iris-Fixated Phakic Intraocular Lens
    Khongar, Peyman Davvalo
    Pralits, Jan O.
    Cheng, Xi
    Pinsky, Peter
    Soleri, Paolo
    Repetto, Rodolfo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (06) : 2311 - 2320
  • [5] Long-term safety and efficacy of a foldable iris-fixated phakic intraocular lens for the correction of myopia
    Royo, Mariano
    Jimenez, Angel
    Pinero, David P.
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (12) : 4491 - 4502
  • [6] Long-term safety and efficacy of a foldable iris-fixated phakic intraocular lens for the correction of myopia
    Mariano Royo
    Ángel Jiménez
    David P. Piñero
    International Ophthalmology, 2023, 43 : 4491 - 4502
  • [7] Computational simulation of aqueous humour dynamics in the presence of a posterior-chamber versus iris-fixed phakic intraocular lens
    Ignacio Fernandez-Vigo, Jose
    Marcos, Alfonso C.
    Agujetas, Rafael
    Maria Montanero, Jose
    Sanchez-Guillen, Ines
    Garcia-Feijoo, Julian
    Pandal-Blanco, Adrian
    Angel Fernandez-Vigo, Jose
    Macarro-Merino, Ana
    PLOS ONE, 2018, 13 (08):
  • [8] Numerical simulation of aqueous flow in a novel posterior chamber phakic intraocular lens versus its counterparts
    Sun, Yifan
    Chen, Jian
    Zhou, Sijie
    Jiang, Yong
    PHYSICS OF FLUIDS, 2023, 35 (05)
  • [9] A Study of the Mechanical Forces on Aphakic Iris-Fixated Intraocular Lenses
    Khongar, Peyman Davvalo
    Pralits, Jan Oscar
    Soleri, Paolo
    Romano, Mario
    Repetto, Rodolfo
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (11):
  • [10] Aqueous flow in the anterior chamber with angle-supported intraocular lens
    Kumar, Ajay
    Babu, A. Benerji
    Flarence, M. R.
    PHYSICS OF FLUIDS, 2025, 37 (02)