In this paper we describe the progress we have made in our simultaneous length measurement and the femtosecond comb interferometric spectroscopy in a conventional arrangement with a moving mirror. Scanning and detection over an interval longer than the distance between two consecutive pulses of the frequency comb allow for a spectral resolution of the individual frequency modes of the comb. Precise knowledge of comb mode frequency leads to a precise estimation of the spectral characteristics of inspected phenomena. Using the pulse train of the frequency comb allows for measurement with highly unbalanced lengths of interferometer arms, i.e. an absolute long distance measurement. Further, we present a non-contact (double sided) method of measurement of the length/thickness of plane-parallel objects (gauge blocks, glass samples) by combining the fs comb (white light) with single frequency laser interferometry. The position of a fringe packet is evaluated by estimating the stationary phase position for any wavelength in the spectral band used. The repeatability of this position estimation is a few nanometres regardless of whether dispersion of the arms is compensated (transform limited fringe packet similar to 10 fringes FWHM) or highly different (fringe packet stretched to >200 fringes FWHM). The measurement of steel gauge block by this method was compared with the standard method, and deviation (+13 +/- 12) nm for gauge blocks (2 to 100) mm was found. The measurement of low reflecting ceramic gauges or clear glass samples was also tested. In the case of glass, it becomes possible to measure simultaneously both the thickness and the refractive index (and dispersion) of flat samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Propagation of the measurement uncertainty in Fourier transform digital holographic interferometry
    Doval, Angel F.
    Trillo, Cristina
    Carlos Lopez-Vazquez, J.
    Fernandez, Jose L.
    OPTICAL ENGINEERING, 2016, 55 (12)
  • [22] Multi-Wavelength Optical Fiber Refractive Index Profiling by Spatially Resolved Fourier Transform Spectroscopy
    Yablon, Andrew D.
    OFC: 2009 CONFERENCE ON OPTICAL FIBER COMMUNICATION, VOLS 1-5, 2009, : 3054 - 3056
  • [23] Arbitrary distance and angle measurement by dynamic dispersive interferometry using a frequency comb
    Xu, Xinyang
    Zhao, Haihan
    Bi, Ying
    Qian, Zhiwen
    Liu, Chao
    Shi, Haonan
    Zhai, Jingsheng
    OPTICS AND LASERS IN ENGINEERING, 2021, 145
  • [24] Acoustic method for determination of the effective temperature and refractive index of air in accurate length interferometry
    Korpelainen, V
    Lassila, A
    OPTICAL ENGINEERING, 2004, 43 (10) : 2400 - 2409
  • [25] Refractive index measurement using single fiber reflectance spectroscopy
    Zhang, Xu U.
    Faber, Dirk J.
    Post, Anouk L.
    van Leeuwen, Ton G.
    Sterenborg, Henricus J. C. M.
    JOURNAL OF BIOPHOTONICS, 2019, 12 (07)
  • [26] Measurement of PDMS Refractive Index by Low-Coherence Interferometry
    Kacik, Daniel
    Tatar, Peter
    Martincek, Ivan
    2014 ELEKTRO, 2014, : 662 - 665
  • [27] Optical frequency comb Fourier transform spectroscopy with sub-nominal resolution and precision beyond the Voigt profile
    Rutkowski, Lucile
    Maslowski, Piotr
    Johansson, Alexandra C.
    Khodabakhsh, Amir
    Foltynowicz, Aleksandra
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2018, 204 : 63 - 73
  • [28] Multichannel Fourier transform Raman spectroscopy: Combining the advantages of CCDs with interferometry
    Zhao, J
    McCreery, RL
    APPLIED SPECTROSCOPY, 1996, 50 (09) : 1209 - 1214
  • [29] Refractive Index Measurement Using Continuous Wave Terahertz Frequency-Domain Spectroscopy
    Zhang Tian-yao
    Li Bo-yang
    Li Xing-yuei
    Li Ying
    Wu Xian-hao
    Zhao Xiao-yan
    Zhang Zhao-hui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (02) : 495 - 502
  • [30] Comparative study on determining the refractive index profile of polypropylene fibres using fast Fourier transform and phase-shifting interferometry
    Yassien, K. M.
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2009, 11 (07):