Why locking plates for the proximal humerus do not fit well

被引:1
作者
Kim, Hyungsuk [1 ]
Chung, Yang-Guk [2 ]
Jang, Ji Seok [1 ]
Kim, Yongdeok [1 ]
Park, Soo Bin [1 ]
Song, Hyun Seok [1 ]
机构
[1] Catholic Univ Korea, Dept Orthoped Surg, Coll Med, Marys Hosp, Eunpyeong St,1021 Tongil Ro, Seoul 03312, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Seoul, South Korea
关键词
Proximal humeral fracture; Locking plate; Compatibility; 3D printing; INTERNAL-FIXATION; FRACTURES; EPIDEMIOLOGY; MANAGEMENT; REDUCTION; ANGLE;
D O I
10.1007/s00402-020-03676-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction We compared the angle of the humerus and plate and to assess compatibility of a plate to the proximal humerus using three-dimensional (3D) printed models. Materials and methods A total of 120 cases were included, who underwent anteroposterior shoulder radiographs. From these, 30 cases with 3D shoulder computed tomography scans were randomly selected to print 3D model. The lateral angle between the lateral cortex of the humeral shaft and lateral border of the greater tuberosity (GT), neck-shaft angle, and height from the most proximal point of the GT to the angular point were measured. When the plates were applied on the 3D models, the gap from the most proximal point of the GT to the proximal rim of the plate was measured. Results The mean lateral angle in plain radiographs was 12.9 +/- 2.2 degrees and height from the most proximal point of the GT to the angular point was 44.4 +/- 4.7 mm. The bending angles of the three plates were 8 degrees and 10 degrees. Height from the proximal rim of the plate to the bending point was 42.4, 42.0 and 43.8 mm. In 98% of cases, the lateral angle of the humerus was larger than all three plates. In 43% of cases, height of the GT was smaller than height of plates. When plates were applied to the 3D model, the mean gap from GT to plate was 4.8 +/- 2.8 mm. Conclusions There was large variation in the lateral angle of the proximal humerus, which was not correlated with the neck-shaft angle. The lateral angle of the humerus was larger than the plates and prone to varus reduction and medial collapse.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 35 条
  • [1] Analysis of efficacy and failure in proximal humerus fractures treated with locking plates
    Agudelo, Juan
    Schuermann, Matthias
    Stahel, Philip
    Helwig, Peter
    Morgan, Steven J.
    Zechel, Wolfgang
    Bahrs, Christian
    Parekh, Anand
    Ziran, Bruce
    Williams, Allison
    Smith, Wade
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (10) : 676 - 681
  • [2] Trends in epidemiology and patho-anatomical pattern of proximal humeral fractures
    Bahrs, Christian
    Stojicevic, Tanja
    Blumenstock, Gunnar
    Brorson, Stig
    Badke, Andreas
    Stockle, Ulrich
    Rolauffs, Bernd
    Freude, Thomas
    [J]. INTERNATIONAL ORTHOPAEDICS, 2014, 38 (08) : 1697 - 1704
  • [3] The epidemiology of peripheral fractures
    Baron, JA
    Barrett, JA
    Karagas, MR
    [J]. BONE, 1996, 18 (03) : S209 - S213
  • [4] Reduction techniques forminimally invasive stabilization of proximal humeral fractures
    Beeres, F. J. P.
    Quaile, O. M.
    Link, B. C.
    Babst, R.
    [J]. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2019, 31 (01): : 63 - 80
  • [5] Butler Matthew A, 2018, Shoulder Elbow, V10, P40, DOI 10.1177/1758573217704816
  • [6] Reverse total shoulder arthroplasty for acute proximal humeral fracture: comparison to open reduction-internal fixation and hemiarthroplasty
    Chalmers, Peter N.
    Slikker, William, III
    Mall, Nathan A.
    Gupta, Anil K.
    Rahman, Zain
    Enriquez, Daniel
    Nicholson, Gregory P.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (02) : 197 - 204
  • [7] The outcome of surgical management of proximal humeral fractures using locking plates: comparison between Locking plates with different geometry
    Chen, Jiun-Liang
    Chang, Fu-Chun
    Lin, Shih-Jie
    Chuang, Po-Yao
    Peng, Kuo-Ti
    Huang, Kuo-Chin
    Huang, Tsan-Wen
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (12) : 2159 - 2166
  • [8] The impacted varus (A2.2) proximal humeral fracture - Prediction of outcome and results of nonoperative treatment in 99 patients
    Court-Brown, CM
    McQueen, MM
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06): : 736 - 740
  • [9] An anthropometric study of the bilateral anatomy of the humerus
    DeLude, Jennifer A.
    Bicknell, Ryan T.
    MacKenzie, Geoff A.
    Ferreira, Louis M.
    Dunning, Cynthia E.
    King, Graham J. W.
    Johnson, James A.
    Drosdowech, Darren S.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (04) : 477 - 483
  • [10] A new locking plate for unstable fractures of the proximal humerus
    Fankhauser, F
    Boldin, C
    Schippinger, G
    Haunschmid, C
    Szyszkowitz, R
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) : 176 - 181