Measurements of the internal magnetic field structures using conventional polarimetric approaches are considered extremely challenging in fusion-reactor environments whereas the information on current density profiles is essential to establish steady-state and advance operation scenarios in such reactor-relevant devices. Therefore, on ITER a hybrid system is proposed for the current density measurements that uses both polarimetry and spectral measurements. The spectrum-based approaches have been tested in the Korea Superconducting Tokamak Advanced Research (KSTAR) during the past two plasma campaigns. As such, KSTAR is a test-bed for the proposed ITER hybrid system. Measurements in the plasma core are based on the motional Stark effect (MSE) spectrum of the neutral beam emission. For the edge profiles, the Zeeman effect (ZE) acting on the lithium emission spectrum of the newly installed (2013) Lithium-beam-diagnostic is exploited. The neutral beam emission spectra, complicated by the multi-ion-source beam injection, are successfully fitted making use of the data provided by the Atomic Data and Analysis Structure (ADAS) database package. This way pitch angle profiles could be retrieved from the beam emission spectra. With the same spectrometer/CCD hardware as on MSE, but with a different wavelength range and different lines of sight, the first ZE spectrum measurements have been made. The Zeeman splitting comparable to and greater than the instrumental broadening has been routinely detected at high toroidal field operations (similar to 3 Tesla).
引用
收藏
页数:8
相关论文
共 11 条
[1]   The motional Stark effect diagnostic for ITER using a line-shift approach [J].
Foley, E. L. ;
Levinton, F. M. ;
Yuh, H. Y. ;
Zakharov, L. E. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)
[2]   Improved spectral analysis for the motional Stark effect diagnostic [J].
Ko, J. ;
Klabacha, J. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10)
[3]   First mirror contamination studies for polarimetry motional Stark effect measurements for ITER [J].
Kuldkepp, M ;
Rachlew, E ;
Hawkes, NC ;
Schunke, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :3446-3448
[4]  
Kwak J.G., 2011, IEEE T PLASMA SCI, V40
[5]   MAGNETIC-FIELD PITCH-ANGLE MEASUREMENTS IN THE PBX-M TOKAMAK USING THE MOTIONAL STARK-EFFECT [J].
LEVINTON, FM ;
FONCK, RJ ;
GAMMEL, GM ;
KAITA, R ;
KUGEL, HW ;
POWELL, ET ;
ROBERTS, DW .
PHYSICAL REVIEW LETTERS, 1989, 63 (19) :2060-2063
[6]   Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited) [J].
Pablant, N. A. ;
Burrell, K. H. ;
Groebner, R. J. ;
Holcomb, C. T. ;
Kaplan, D. H. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10)
[7]   Status and characterization of the lithium beam diagnostic on DIII-D [J].
Stoschus, H. ;
Thomas, D. M. ;
Hudson, B. ;
Watkins, M. ;
Finkenthal, D. F. ;
Moyer, R. A. ;
Osborne, T. H. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (08)
[8]   Measurement of pressure-gradient-driven currents in tokamak edge plasmas [J].
Thomas, DM ;
Leonard, AW ;
Lao, LL ;
Osborne, TH ;
Mueller, HW ;
Finkenthal, DF .
PHYSICAL REVIEW LETTERS, 2004, 93 (06) :065003-1
[9]   Poloidal magnetic field measurements and analysis with the DIII-D LIBEAM system (invited) [J].
Thomas, DM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03) :1541-1546
[10]   Prospects for edge current density determination using LIBEAM on DIII-D [J].
Thomas, DM ;
Bozek, AS ;
Robinson, JI ;
Burrell, KH ;
Carlstrom, TN ;
Osborne, TH ;
Snider, RT ;
Finkenthal, DK ;
Jayakumar, R ;
Makowski, MA ;
Nilson, DG ;
Rice, BW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) :1023-1027