Gas mass-flow meters: Measurement and uncertainties

被引:5
作者
Amador de Matos, Manuel Arlindo [1 ]
Fernandes Rodrigues, Nuno Jose [2 ]
机构
[1] Univ Aveiro, Dept Environm & Planning, P-3810193 Aveiro, Portugal
[2] LMEG, Lab Gas Metrol, Lda, Portugal
关键词
Gas mass-flow meters; Dynamic volumetric method; Response factor; Calibration; Gas mixtures; Gas sensors; Gas flow measurement; Uncertainty;
D O I
10.1016/j.flowmeasinst.2013.04.011
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The application of gas mass-flow meters (GMFM) sensors needs the knowledge of its measurement model and measurement uncertainties. It was already known that the GMFM output model depends on gas mass-flow and gas composition. In this work, different throughput GMFM sensors were used for different gas flow rates and gas composition in order to verify and to improve the GMFM measurement model. A direct calibration procedure and a dynamic volumetric method were applied both to get the measurement model and to evaluate the performance of gas sensors and GMFM sensors against certified reference materials and suitable standards. Additionally, the obtained data were used both to calculate the uncertainties of gas mass-flow measurement and to improve the GMFM gas response factors. The calculated uncertainties of the GMFM direct measurement was approximately 2% of the measured value. The uncertainty of the dynamic volumetric method developed in this work was found as approximately 5% of the measured value and that was mainly influenced by the uncertainties of the standards used. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 50 条
[41]   Comparison of Two Experiments Based on a Physical and a Torsion Pendulum to Determine the Mass Moment of Inertia Including Measurement Uncertainties [J].
Klaus, Leonard .
MEASUREMENT SCIENCE REVIEW, 2017, 17 (01) :9-18
[42]   Gas Flow Measurement with Wide Range Using Multi-thermistors [J].
Zhao, Weiguo ;
Zhou, Haojie ;
Zhang, Shengyi .
2016 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, 2016, :1144-1149
[43]   Validation of gas flow measurement during ozone generator performance testing [J].
Rakness, KL ;
Henry, D ;
Langlais, B .
OZONE-SCIENCE & ENGINEERING, 2000, 22 (01) :1-22
[44]   Estimating contaminant mass discharge: A field comparison of the multilevel point measurement and the integral pumping investigation approaches and their uncertainties [J].
Beland-Pelletier, Caroline ;
Fraser, Michelle ;
Barker, Jim ;
Ptak, Thomas .
JOURNAL OF CONTAMINANT HYDROLOGY, 2011, 122 (1-4) :63-75
[45]   Influence of flow disturbances on the performance of industry-standard LNG flow meters [J].
Kenbar, Asaad ;
Schakel, Menne .
FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 77
[46]   Revisiting type-A uncertainties relating to the measurement of mass fraction of lead using isotope-dilution inductively coupled plasma mass spectrometry: a way of improving measurement precision and expanded uncertainty [J].
James Chung Wah Lam ;
Yiu Chung Yip ;
Wai Fong Tong .
Accreditation and Quality Assurance, 2008, 13 :311-319
[47]   The evaluation of measurement uncertainties and its epistemological ramifications [J].
de Courtenay, Nadine ;
Gregis, Fabien .
STUDIES IN HISTORY AND PHILOSOPHY OF SCIENCE, 2017, 65-66 :21-32
[48]   Number and phase: complementarity and joint measurement uncertainties [J].
Lahti, Pekka ;
Pellonpaa, Juha-Pekka ;
Schultz, Jussi .
JOURNAL OF PHYSICS A-MATHEMATICAL AND THEORETICAL, 2017, 50 (37)
[49]   Determination of colorimetric uncertainties in the spectrophotometric measurement of colour [J].
Clarke, PJ ;
Hanson, AR ;
Verrill, JF .
ANALYTICA CHIMICA ACTA, 1999, 380 (2-3) :277-284
[50]   Measurement uncertainties in resonant characteristics of MEMS resonators [J].
Lee, Il ;
Lee, Jungchul .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2013, 27 (02) :491-500