Short to Midterm Follow-Up of the Tritanium Primary Acetabular Component: A Cause for Concern

被引:45
作者
Carli, Alberto V. [1 ]
Warth, Lucian C. [1 ]
Bentley, Karen L. de Mesy [2 ]
Nestor, Bryan J. [1 ]
机构
[1] Hosp Special Surg, Dept Orthopaed Surg, 535 E 70th St, New York, NY 10021 USA
[2] Univ Rochester, Med Ctr, Dept Pathol & Lab Med, Rochester, NY 14642 USA
关键词
primary hip arthroplasty; acetabular fixation; osseointegration failure; Trabecular Metal; ultraporous metal substrates; TOTAL HIP-REPLACEMENT; TITANIUM CUP; ARTHROPLASTY; FIXATION; TERM; REVISION; FAILURE;
D O I
10.1016/j.arth.2016.07.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Several acetabular components utilizing novel ultraporous metal substrates have been introduced over the past decade. Collectively by design, they have a lower modulus of elasticity to reduce stress shielding, a higher coefficient of friction to enhance interference fit, and ultraporous surfaces to enhance osseointegration. However, little literature exists regarding their clinical performance. Methods: This study compared the clinical and radiographic results of 109 hips in 95 patients using a Tritanium primary cup (Stryker, Mahwah, NJ) to an age, body mass index, and gender-matched cohort of 100 patients that received a contemporary cup (Stryker Trident PSL HA). Results: At an average 4.24 + 1.49 years, implant survivorship of the Tritanium primary cup was 98.2%, with 2 cups revised for failure of osseointegration. One-year radiographs revealed radiolucent and radiosclerotic lines in 2 or more DeLee zones in 30.3% of cups and 3 zone involvement in 8.2%. These proportions increased (40.0% and 17.1%, respectively) at minimum 5-year follow-up. A comparison of 1 year and last follow-up radiographs revealed progression in 13.8%. Tritanium primary components with radiolucency in 2 or more zones exhibited significantly lower HHS at 2 years compared to all Trident peripheral self-locking (PSL) components (P<.0001) and Tritanium primary components with 1 zone or no radiolucency (P=.026). Scanning electron microscopy of a retrieved cup revealed local inflammatory reaction and no evidence of osseointegration. Conclusion: Despite adequate implant survivorship, over one third of Tritanium primary cups had 2 or more zone radiolucency at minimum 5-year follow-up with associated lower Harris hip scores. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 29 条
[1]  
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[2]  
Bobyn JD, 2011, ORTHOPAEDIC KNOWLEDG, V4, P45
[3]  
Bonicoli Enrico, 2012, Surg Technol Int, V22, P229
[4]   RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[5]  
D'Lima D, 2001, J BONE JOINT SURG AM, V83-A
[6]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[7]   Uncemented total hip arthroplasty for primary osteoarthritis in young patients - A mid- to long-term follow-up study from the Finnish Arthroplasty Register [J].
Eskelinen, A ;
Remes, V ;
Helenius, I ;
Pulkkinen, P ;
Nevalainen, J ;
Paavolainen, P .
ACTA ORTHOPAEDICA, 2006, 77 (01) :57-70
[8]   The results of the titanium-coated RM acetabular component at 20 years: A term follow-up of an uncemented primary total hip replacement [J].
Ihle, M. ;
Mai, S. ;
Pfluger, D. ;
Siebert, W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10) :1284-1290
[9]   Early radiological observations may predict the long-term survival of femoral hip prostheses [J].
Kobayashi, A ;
Donnelly, WJ ;
Scott, G ;
Freeman, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (04) :583-589
[10]  
Kremers Hilal Maradit, 2012, J Bone Joint Surg Am, V94, pe82, DOI 10.2106/JBJS.K.00549