Radar Remote Monitoring of Vital Signs

被引:190
作者
Li, Changzhi [1 ]
Cummings, Julie [1 ]
Lam, Jeffrey [1 ]
Graves, Eric [1 ]
Wu, Wenhsing [1 ]
机构
[1] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
关键词
4; SIDES; HEARTBEAT; MOVEMENT; RADIO; CHIP;
D O I
10.1109/MMM.2008.930675
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The development of microwave Doppler radar phase modulation has led to the introduction of alternative sources for noncontact respiration and heartbeat monitoring. It is observed that a Doppler radar uses double-sideband transmission for vital sign detection from four sides of a human body. An unmodulated radio-frequency signal is transmitted toward the human body, where it is phase-modulated by the periodic physiological movement and reflected back to the receiver. It is observed that the radar receiver captures the reflected signal and demodulates it to extract the vital sign signal components. Microwave Doppler phase-modulation has several advantages over conventional noncontact measurement methods. The microwave method does not confine or inhibit the patient and performs monitoring of vita signs, without causing discomfort, or skin irritation. The method is beneficial for monitoring vital signs over extended periods of time, making the detector suitable for long-term continuous monitoring.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 34 条
  • [1] [Anonymous], WORLD C MED PHYS BIO
  • [2] Boric-Lubecke O, 2005, TELSIKS 2005, PROCEEDINGS, VOLS 1 AND 2, P7
  • [3] Boric-Lubecke O, 2003, 2003 IEEE TOPICAL CONFERENCE ON WIRELESS COMMUNICATION TECHNOLOGY, P206
  • [4] Budge M. C. Jr., 1993, Proceedings IEEE Southeastcon '93 (Cat. No.93CH3295-3), DOI 10.1109/SECON.1993.465731
  • [5] AN X-BAND MICROWAVE LIFE-DETECTION SYSTEM
    CHEN, KM
    MISRA, D
    WANG, H
    CHUANG, HR
    POSTOW, E
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (07) : 697 - 701
  • [6] CHEN KM, 1994, P 1994 URSI RAD SCI, P19
  • [7] CHEN KM, 1996, P 1996 IEEE APS URSI, P35
  • [8] Metabolism of the hamster pancreatic carcinogen methyl-2-oxopropylnitrosamme by hamster liver and pancreas
    Chen, SC
    Wang, XJ
    Zhou, L
    Kolar, C
    Lawson, TA
    Mirvish, SS
    [J]. INTERNATIONAL JOURNAL OF PANCREATOLOGY, 2000, 27 (02) : 105 - 112
  • [9] AUTOMATIC CLUTTER-CANCELER FOR MICROWAVE LIFE-DETECTION SYSTEMS
    CHUANG, HR
    CHEN, YF
    CHEN, KM
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (04) : 747 - 750
  • [10] Droitcour A, 2001, IEEE MTT S INT MICR, P175, DOI 10.1109/MWSYM.2001.966866