Corrosion behavior of titanium in response to sulfides produced by Porphyromonas gingivalis

被引:17
|
作者
Harada, Rino [1 ,2 ]
Kokubu, Eitoyo [2 ,3 ]
Kinoshita, Hideaki [1 ]
Yoshinari, Masao [2 ]
Ishihara, Kazuyuki [2 ,3 ]
Kawada, Eiji [1 ]
Takemoto, Shinji [1 ,2 ]
机构
[1] Tokyo Dent Coll, Dept Dent Mat Sci, Chiyoda Ku, 2-9-18 Misaki Cho, Tokyo 1010061, Japan
[2] Tokyo Dent Coll, Oral Hlth Sci Ctr, Chiyoda Ku, 2-9-18 Misaki Cho, Tokyo 1010061, Japan
[3] Tokyo Dent Coll, Dept Microbiol, Chiyoda Ku, 2-9-18 Misaki Cho, Tokyo 1010061, Japan
关键词
Titanium; Corrosion; Sulfide; Bacterial adhesion; Biomaterials; Dental implants; COMMERCIALLY PURE TITANIUM; DENTAL IMPLANTS; ORAL ENVIRONMENT; IN-VITRO; TI-6AL-4V ALLOYS; FLUORIDE; RESISTANCE; ABUTMENTS; PEROXIDE; SURFACES;
D O I
10.1016/j.dental.2017.10.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To investigate the effects of sulfides produced by Porphyromonas gingivalis (P. gingivalis) on the corrosion behavior of titanium. Methods. Commercially pure titanium disks were mirror-polished and immersed in culture medium (BHI), spent medium after culturing P. gingivalis (BHI-S), and culture medium with P. gingivalis (BHI-P), and incubated aerobically at 37 degrees C for 3-14 days. Titanium corrosion was evaluated through surface observation (using scanning electron microscope: SEM), color change (Delta E*ab), glossiness (Gs(20 degrees)), chemical composition and state (using X-ray photoelectron spectroscopy: XPS), and titanium release. Results. Delta 6E*ab and Gs(20 degrees) did not significantly differ among specimens placed in test mediums for the study duration (p > 0.05). SEM images of specimens showed no signs of localized or overall corrosion. XPS analysis indicated showed clear titanium metal state peaks on all specimens in addition to sulfide and sulfate on BHI-S and BHI-P specimens. Valency fraction of titanium decomposed from Ti2p spectrum of BHI-S and BHI-P specimens indicated no progression of oxidation. No significant levels of titanium release were found regardless of the mediums' sulfide content. Results suggested that sulfides produced by P. gingivalis attached on the surface of titanium specimens but did not cause titanium corrosion over the immersion period of 14 days. Significance. It is imperative for dental practitioners to be aware of any elements which may influence the clinical success of titanium implants. (C) 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:183 / 191
页数:9
相关论文
共 50 条
  • [21] Assessment of nickel titanium and beta titanium corrosion resistance behavior in fluoride and chloride environments
    Kassab, Elisa J.
    Gomes, Jose Ponciano
    ANGLE ORTHODONTIST, 2013, 83 (05) : 864 - 869
  • [22] Corrosion mechanisms in titanium oxide-based films produced by anodic treatment
    Alves, A. C.
    Wenger, F.
    Ponthiaux, P.
    Celis, J. -P.
    Pinto, A. M.
    Rocha, L. A.
    Fernandes, J. C. S.
    ELECTROCHIMICA ACTA, 2017, 234 : 16 - 27
  • [23] Effects of Titanium Corrosion Products on In Vivo Biological Response: A Basis for the Understanding of Osseointegration Failures Mechanisms
    Biguetti, Claudia Cristina
    Cavalla, Franco
    Fonseca, Angelica Cristina
    Tabanez, Andre Petenucci
    Siddiqui, Danyal A.
    Wheelis, Sutton E.
    Taga, Rumio
    Fakhouri, Walid D.
    Silva, Renato Menezes
    Rodrigues, Danieli C.
    Garlet, Gustavo Pompermaier
    FRONTIERS IN MATERIALS, 2021, 8
  • [24] Corrosion and biological study on biofunctionalized porous coating on titanium produced by plasma electrolytic oxidation
    Valizade, Nima
    Aghdam, Alireza Sabour Rouh
    Jarjoura, George
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2024, 688
  • [25] Corrosion Behavior of Cold Sprayed Titanium Coatings and Free Standing Deposits
    Hussain, T.
    McCartney, D. G.
    Shipway, P. H.
    Marrocco, T.
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2011, 20 (1-2) : 260 - 274
  • [26] Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use
    Nakagawa, M
    Matsuya, S
    Shiraishi, T
    Ohta, M
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (09) : 1568 - 1572
  • [27] Corrosion behavior and surface characterization of titanium in solution containing fluoride and albumin
    Takemoto, S
    Hattori, M
    Yoshinari, M
    Kawada, E
    Oda, Y
    BIOMATERIALS, 2005, 26 (08) : 829 - 837
  • [28] Surface analysis and corrosion behavior of pure titanium under fluoride exposure
    Chen, Wan-Qing
    Zhang, Song Mei
    Qiu, Jing
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02) : 239.e1 - 239.e8
  • [29] Influence of fluoride concentration and pH on corrosion behavior of titanium in artificial saliva
    Alain Robin
    Jeferson Paulino Meirelis
    Journal of Applied Electrochemistry, 2007, 37 : 511 - 517
  • [30] Corrosion behavior of β titanium alloys for biomedical applications
    Atapour, M.
    Pilchak, A. L.
    Frankel, G. S.
    Williams, J. C.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (05): : 885 - 891