Monte Carlo study of the scattered radiation field near the eyes of the operator in interventional procedures

被引:21
|
作者
Ferrari, Paolo [1 ]
Becker, Frank [2 ]
Carinou, Eleftheria [3 ]
Chumak, Vadim [4 ]
Farah, Jad [5 ]
Jovanovic, Zoran [6 ]
Krstic, Dragana [6 ]
Morgun, Artem [4 ]
Principi, Sara [7 ]
Teles, Pedro [8 ]
机构
[1] ENEA Radiat Protect Inst, 4 Via Martiri di Monte Sole, I-40129 Bologna, BO, Italy
[2] Karlsruhe Inst Technol, Inst Nucl Waste Disposal, Hermann von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafen, Germany
[3] GAEC Greek Atom Energy Commiss, Attiki 15310, Greece
[4] NAMS Ukraine, Natl Res Ctr Radiat Med, Melnikova 53, UA-04050 Kiev, Ukraine
[5] IRSN, PRP HOM, SDE, LDRI, BP 17, F-92262 Fontenay Aux Roses, France
[6] Univ Kragujevac, Fac Sci, 12 R Domanovic, Kragujevac 34000, Serbia
[7] Univ Politecn Cataluna, Inst Tecn Energet, Diagonal 647, E-08028 Barcelona, Spain
[8] Ctr Ciencias & Tecnol Nucl C2TN, Grp Protecao & Seguranca Radiol, CTN IST, Polo De Loures, Bobadela, Portugal
关键词
eye lens; interventional radiology; interventional cardiology; lead glasses; shielding; Monte Carlo; medical staff dose monitoring; LENS DOSIMETRY; CATARACT RISK; EXPOSURE; RADIOLOGY; PROTECTION; STAFF; CALIBRATION; QUANTITIES; PATIENT; EYEWEAR;
D O I
10.1088/0952-4746/36/4/902
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Interventional radiology and cardiology guarantee high benefits for patients, but are known to be associated with a high level of radiation exposure of medical staff. The recently suggested decrease of the annual dose limit for the eye lens, from 150 to 20 mSv, caused a need for a reconsideration of practices ensuring sufficient protection for the lens of the eyes of medical staff. In such context the study of the scattered radiation around the operator's head could help in finding the best solutions to be adopted for the ceiling-suspended shield and lead glasses in the most common situations in interventional practices. MCNPX Monte Carlo code was employed with anthropomorphic mathematical phantoms to simulate interventional practice projections. For each projection the effect of changing selected parameters on the evaluated scattered radiation towards the operator's head has been calculated. The variety of modelled situations provides plentiful material regarding the spatial distribution of the scattered radiation, useful to improve eye lens radiation protection, such as the following: (a) Glasses, which provide shielding from both lateral and bottom-up scattered radiation, can reduce by ten times the exposure to the most exposed eyes; (b) The ceiling-suspended shield offers valuable protection, but such effectiveness can diminish by 90% if the shielding is not correctly positioned; (c) The transition from femoral to radial access usually intensifies the scattered radiation toward the operator head (a factor of 1.5 for AP projection), but for RAO projections, a reduction of the order by two to three times, in the case of radial access, can be seen, due to the protection provided by the image receptor. The detailed fluence outcomes show that there is a preferential direction of the impinging scattered radiation that should be considered when radiation protection options are evaluated or when a dedicated eye lens dosemeter is used for monitoring.
引用
收藏
页码:902 / 921
页数:20
相关论文
共 50 条
  • [41] Radiation exposure of operator performing interventional procedures using a flat panel angiography system: evaluation with photoluminescence glass dosimeters
    Yoshinori Funama
    Nozomu Nagasue
    Kazuo Awai
    Ichiro Sakamoto
    Kiyotaka Kakei
    Masamichi Shimamura
    Yasuyuki Yamashita
    Masataka Uetani
    Japanese Journal of Radiology, 2010, 28 : 423 - 429
  • [42] Radiation risk assessment in neonatal radiographic examinations of the chest and abdomen: a clinical and Monte Carlo dosimetry study
    Makri, T.
    Yakoumakis, E.
    Papadopoulou, D.
    Gialousis, G.
    Theodoropoulos, V.
    Sandilos, P.
    Georgiou, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (19) : 5023 - 5033
  • [43] Radiation characteristics of water droplets in a fire-inspired environment: A Monte Carlo ray tracing study
    Wu, Bifen
    Zhao, Xinyu
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2018, 212 : 97 - 111
  • [44] A Monte Carlo study of random surface field effect on layering transitions
    Ez-Zahraouy, H
    Bahmad, L
    Benyoussef, A
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2005, 358 (01) : 86 - 92
  • [45] Patient radiation dose during diagnostic and interventional cardiology procedures A study in a tertiary hospital
    Anim-Sampong, Samuel
    Antwi, William Kwadwo
    Adomako, John Bright
    Botwe, Benard Ohene
    Sarkodie, Benjamin Dabo
    Brakohiapa, Edmund K.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2023, 54 (02) : 298 - 305
  • [46] Brain motion induced artefacts in Microbeam Radiation Therapy: a Monte Carlo study
    Donzelli, M.
    Brauer-Krisch, E.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S34 - S35
  • [47] Assessment of scattered radiation from hand-held dental x-ray equipment using the Monte Carlo method
    Batista, Wilson Otto
    Soares, Maria Rosangela
    Gurjao Rios, Jacqueline Machado
    Dos Santos Souza, Antonio Carlos
    Pinheiro, Isabelle Matos
    Javier Vega Ramirez, Jose Luis
    Caldas, Linda V. E.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : 654 - 668
  • [48] Monte carlo study of organ doses and related risk for cancer in Tanzania from scattered photons in cervical radiation treatment involving Co-60 source
    Suleiman, Suleiman Ameir
    Qi, Yaping
    Chen, Zhi
    Xu, X. George
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 62 : 13 - 19
  • [49] A study of the interplay effect in radiation therapy using a Monte-Carlo model
    Leste, Jeremy
    Medjahed, Imene
    Chauvin, Maxime
    Younes, Tony
    Vieillevigne, Laure
    Ferrand, Regis
    Franceries, Xavier
    Bardies, Manuel
    Simon, Luc
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 73 - 82
  • [50] Usefulness of an additional lead shielding device in reducing occupational radiation exposure during interventional endoscopic procedures An observational study
    Yamada, Reiko
    Saimyo, Yusuke
    Tanaka, Kyosuke
    Hattori, Aiji
    Umeda, Yuhei
    Kuroda, Naoki
    Tsuboi, Junya
    Hamada, Yasuhiko
    Takei, Yoshiyuki
    MEDICINE, 2020, 99 (34) : E21831