Monte Carlo study of the scattered radiation field near the eyes of the operator in interventional procedures

被引:21
|
作者
Ferrari, Paolo [1 ]
Becker, Frank [2 ]
Carinou, Eleftheria [3 ]
Chumak, Vadim [4 ]
Farah, Jad [5 ]
Jovanovic, Zoran [6 ]
Krstic, Dragana [6 ]
Morgun, Artem [4 ]
Principi, Sara [7 ]
Teles, Pedro [8 ]
机构
[1] ENEA Radiat Protect Inst, 4 Via Martiri di Monte Sole, I-40129 Bologna, BO, Italy
[2] Karlsruhe Inst Technol, Inst Nucl Waste Disposal, Hermann von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafen, Germany
[3] GAEC Greek Atom Energy Commiss, Attiki 15310, Greece
[4] NAMS Ukraine, Natl Res Ctr Radiat Med, Melnikova 53, UA-04050 Kiev, Ukraine
[5] IRSN, PRP HOM, SDE, LDRI, BP 17, F-92262 Fontenay Aux Roses, France
[6] Univ Kragujevac, Fac Sci, 12 R Domanovic, Kragujevac 34000, Serbia
[7] Univ Politecn Cataluna, Inst Tecn Energet, Diagonal 647, E-08028 Barcelona, Spain
[8] Ctr Ciencias & Tecnol Nucl C2TN, Grp Protecao & Seguranca Radiol, CTN IST, Polo De Loures, Bobadela, Portugal
关键词
eye lens; interventional radiology; interventional cardiology; lead glasses; shielding; Monte Carlo; medical staff dose monitoring; LENS DOSIMETRY; CATARACT RISK; EXPOSURE; RADIOLOGY; PROTECTION; STAFF; CALIBRATION; QUANTITIES; PATIENT; EYEWEAR;
D O I
10.1088/0952-4746/36/4/902
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Interventional radiology and cardiology guarantee high benefits for patients, but are known to be associated with a high level of radiation exposure of medical staff. The recently suggested decrease of the annual dose limit for the eye lens, from 150 to 20 mSv, caused a need for a reconsideration of practices ensuring sufficient protection for the lens of the eyes of medical staff. In such context the study of the scattered radiation around the operator's head could help in finding the best solutions to be adopted for the ceiling-suspended shield and lead glasses in the most common situations in interventional practices. MCNPX Monte Carlo code was employed with anthropomorphic mathematical phantoms to simulate interventional practice projections. For each projection the effect of changing selected parameters on the evaluated scattered radiation towards the operator's head has been calculated. The variety of modelled situations provides plentiful material regarding the spatial distribution of the scattered radiation, useful to improve eye lens radiation protection, such as the following: (a) Glasses, which provide shielding from both lateral and bottom-up scattered radiation, can reduce by ten times the exposure to the most exposed eyes; (b) The ceiling-suspended shield offers valuable protection, but such effectiveness can diminish by 90% if the shielding is not correctly positioned; (c) The transition from femoral to radial access usually intensifies the scattered radiation toward the operator head (a factor of 1.5 for AP projection), but for RAO projections, a reduction of the order by two to three times, in the case of radial access, can be seen, due to the protection provided by the image receptor. The detailed fluence outcomes show that there is a preferential direction of the impinging scattered radiation that should be considered when radiation protection options are evaluated or when a dedicated eye lens dosemeter is used for monitoring.
引用
收藏
页码:902 / 921
页数:20
相关论文
共 50 条
  • [31] A Monte Carlo study on the effect of the orbital bone to the radiation dose delivered to the eye lens
    Stratis, Andreas
    Zhang, Guozhi
    Jacobs, Reinhilde
    Bogaerts, Ria
    Bosmans, Hilde
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [32] A Monte Carlo investigation on the impact of scattered radiation on mammographic resolution and noise - art. no. 61423A
    Saunders, Robert S.
    Samei, Ehsan
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : A1423 - A1423
  • [33] MONTE CARLO SIMULATION STUDY ON THE 241Am-Be RADIONUCLIDE SOURCE REFERENCE NEUTRON RADIATION
    Liu, Yixin
    Zhang, Song
    Qian, Yikun
    Huang, Yuchen
    Mao, Benjiang
    Feng, Peng
    Chen, Zhiqiang
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2020, 35 (04) : 283 - 293
  • [34] Characteristics of lead glass for radiation protection purposes: A Monte Carlo study
    Zadehrafi, M.
    Olaru, C.
    Ciobanu, S. A.
    Ormenisan, G., V
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (04): : 907 - 912
  • [35] Monte Carlo study of the free radical yields in minibeam radiation therapy
    Masilela, Thongchai A. M.
    Prezado, Yolanda
    MEDICAL PHYSICS, 2023, 50 (08) : 5115 - 5134
  • [36] The global optimal reference field for the difference formulation in the implicit Monte Carlo radiation transport
    Yan, Kai
    JOURNAL OF COMPUTATIONAL PHYSICS, 2021, 435
  • [37] Monte Carlo simulation of semiconductor-based detector in mixed radiation field in the atmosphere
    Sommer, Marek
    Johnova, Kamila
    Ploc, Ondrej
    Benton, Eric R.
    Sihver, Lembit
    LIFE SCIENCES IN SPACE RESEARCH, 2022, 34 : 30 - 36
  • [38] Comparison of experimental measurements and fast Monte Carlo simulations for typical set-ups in fluoroscopically-guided interventional procedures
    Balcaza, V. Garcia
    Pages, Marta Barcelo
    Martinez, Agustin Ruiz
    Campa, Anna
    Ginjaume, Merce
    Ducha, Maria Amor
    RADIATION MEASUREMENTS, 2024, 175
  • [39] Monte Carlo study toward the development of a radiation field to simulate secondary neutrons produced in carbon-ion radiotherapy
    Yonai, Shunsuke
    Matsumoto, Shinnosuke
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172
  • [40] IMPACT OF RADIATION FIELD SIZE ON ABSORBED ORGAN DOSES IN NEONATES UNDERGOING CHEST RADIOGRAPHY IN AN ANTERIOR-POSTERIOR PROJECTION: A MONTE CARLO SIMULATION STUDY
    Elshami, Wiam
    Tekin, H. O.
    Abuzaid, Mohamed M.
    Issa, Bashar
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (1-2) : 44 - 52