Monte Carlo study of the scattered radiation field near the eyes of the operator in interventional procedures

被引:21
|
作者
Ferrari, Paolo [1 ]
Becker, Frank [2 ]
Carinou, Eleftheria [3 ]
Chumak, Vadim [4 ]
Farah, Jad [5 ]
Jovanovic, Zoran [6 ]
Krstic, Dragana [6 ]
Morgun, Artem [4 ]
Principi, Sara [7 ]
Teles, Pedro [8 ]
机构
[1] ENEA Radiat Protect Inst, 4 Via Martiri di Monte Sole, I-40129 Bologna, BO, Italy
[2] Karlsruhe Inst Technol, Inst Nucl Waste Disposal, Hermann von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafen, Germany
[3] GAEC Greek Atom Energy Commiss, Attiki 15310, Greece
[4] NAMS Ukraine, Natl Res Ctr Radiat Med, Melnikova 53, UA-04050 Kiev, Ukraine
[5] IRSN, PRP HOM, SDE, LDRI, BP 17, F-92262 Fontenay Aux Roses, France
[6] Univ Kragujevac, Fac Sci, 12 R Domanovic, Kragujevac 34000, Serbia
[7] Univ Politecn Cataluna, Inst Tecn Energet, Diagonal 647, E-08028 Barcelona, Spain
[8] Ctr Ciencias & Tecnol Nucl C2TN, Grp Protecao & Seguranca Radiol, CTN IST, Polo De Loures, Bobadela, Portugal
关键词
eye lens; interventional radiology; interventional cardiology; lead glasses; shielding; Monte Carlo; medical staff dose monitoring; LENS DOSIMETRY; CATARACT RISK; EXPOSURE; RADIOLOGY; PROTECTION; STAFF; CALIBRATION; QUANTITIES; PATIENT; EYEWEAR;
D O I
10.1088/0952-4746/36/4/902
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Interventional radiology and cardiology guarantee high benefits for patients, but are known to be associated with a high level of radiation exposure of medical staff. The recently suggested decrease of the annual dose limit for the eye lens, from 150 to 20 mSv, caused a need for a reconsideration of practices ensuring sufficient protection for the lens of the eyes of medical staff. In such context the study of the scattered radiation around the operator's head could help in finding the best solutions to be adopted for the ceiling-suspended shield and lead glasses in the most common situations in interventional practices. MCNPX Monte Carlo code was employed with anthropomorphic mathematical phantoms to simulate interventional practice projections. For each projection the effect of changing selected parameters on the evaluated scattered radiation towards the operator's head has been calculated. The variety of modelled situations provides plentiful material regarding the spatial distribution of the scattered radiation, useful to improve eye lens radiation protection, such as the following: (a) Glasses, which provide shielding from both lateral and bottom-up scattered radiation, can reduce by ten times the exposure to the most exposed eyes; (b) The ceiling-suspended shield offers valuable protection, but such effectiveness can diminish by 90% if the shielding is not correctly positioned; (c) The transition from femoral to radial access usually intensifies the scattered radiation toward the operator head (a factor of 1.5 for AP projection), but for RAO projections, a reduction of the order by two to three times, in the case of radial access, can be seen, due to the protection provided by the image receptor. The detailed fluence outcomes show that there is a preferential direction of the impinging scattered radiation that should be considered when radiation protection options are evaluated or when a dedicated eye lens dosemeter is used for monitoring.
引用
收藏
页码:902 / 921
页数:20
相关论文
共 50 条
  • [1] Seeing is believing: increasing intraoperative awareness to scattered radiation in interventional procedures by combining augmented reality, Monte Carlo simulations and wireless dosimeters
    Rodas, Nicolas Loy
    Padoy, Nicolas
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (08) : 1181 - 1191
  • [2] A parametric study of occupational radiation dose in interventional radiology by Monte-Carlo simulations
    Abdelrahman, Mahmoud
    Lombardo, Pasquale
    Camp, Anna
    Duch, Maria A.
    Phillips, Christophe
    Seret, Alain
    Vanhavere, Filip
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 58 - 70
  • [3] Clarifying and Visualizing Sources of Staff-Received Scattered Radiation in Interventional Procedures
    Chida, Koichi
    Takahashi, Takeshi
    Ito, Daisuke
    Shimura, Hirotaka
    Takeda, Ken
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (05) : W900 - W903
  • [4] Study of the parameters affecting operator doses in interventional radiology using Monte Carlo simulations
    Koukorava, C.
    Carinou, E.
    Ferrari, P.
    Krim, S.
    Struelens, L.
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1216 - 1222
  • [5] Seeing is believing: increasing intraoperative awareness to scattered radiation in interventional procedures by combining augmented reality, Monte Carlo simulations and wireless dosimeters
    Nicolas Loy Rodas
    Nicolas Padoy
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1181 - 1191
  • [6] Influences of operator head posture and protective eyewear on eye lens doses in interventional radiology: A Monte Carlo Study
    Mao, Li
    Liu, Tianyu
    Caracappa, Peter F.
    Lin, Hui
    Gao, Yiming
    Dauer, Lawrence T.
    Xu, X. George
    MEDICAL PHYSICS, 2019, 46 (06) : 2744 - 2751
  • [7] Monte Carlo simulation of TLD response function: Scattered radiation field application
    Shirazi, Alireza
    Mahdavi, Seied Rabie
    Khodadadee, Ali
    Ghaffory, Mostafa
    Mesbahi, Asghar
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2008, 13 (01) : 23 - 28
  • [8] Operator Radiation Dose Reduction During Fluoroscopic Interventional Procedures
    Nachiappan, Arun C.
    Horn, Gag L.
    Spann, Stephanie C.
    Mayo, Ray C.
    Wynne, David M.
    Archer, Benjamin R.
    Whigham, Cliff J.
    Hancock, John A.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (05) : 527 - 530
  • [9] Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures
    Efstathopoulos, E. P.
    Pantos, I.
    Andreou, M.
    Gkatzis, A.
    Carinou, E.
    Koukorava, C.
    Kelekis, N. L.
    Brountzos, E.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997) : 70 - 77
  • [10] Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses
    Koukorava, C.
    Farah, J.
    Struelens, L.
    Clairand, I.
    Donadille, L.
    Vanhavere, F.
    Dimitriou, P.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (03) : 509 - 528