Biomechanical effect with respect to the sagittal positioning of the femoral component in unicompartmental knee arthroplasty

被引:14
作者
Park, Kwan Kyu [1 ]
Koh, Yong-Gon [2 ]
Park, Kyoung-Mi [3 ]
Park, Joon-Hee [4 ]
Kang, Kyoung-Tak [3 ]
机构
[1] Yonsei Univ, Dept Orthoped Surg, Coll Med, Seoul, South Korea
[2] Yonsei Sarang Hosp, Joint Reconstruct Ctr, Dept Orthopaed Surg, Seoul, South Korea
[3] Yonsei Univ, Dept Mech Engn, 50 Yonsei Ro, Seoul 03722, South Korea
[4] Hallym Univ, Kangdong Sacred Heart Hosp, Dept Anesthesiol & Pain Med, Coll Med, Seoul, South Korea
关键词
Unicompartmental knee arthroplasty; malalignment; finite element analysis; POSTERIOR CRUCIATE LIGAMENT; FINITE-ELEMENT-ANALYSIS; JOINT BIOMECHANICS; IN-VIVO; ANATOMY; MENISCECTOMY; INCLINATION; ACCURACY; OUTCOMES; IMPLANT;
D O I
10.3233/BME-191042
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: Component malalignment in unicompartmental knee arthroplasty (UKA) has been related to the concentration in tibiofemoral joint of contact stress and to poor post-operative outcomes. Few studies investigated a biomechanical effect of femur component position in sagittal plane. The purpose of this study was to evaluate the biomechanical effect of the femoral components on the sagittal alignment under flexion and extension conditions using computational simulations. METHODS: The flexion and extension conditions of the femoral component were analyzed from 10 degrees extension to 10 degrees flexion in 1 degrees increments. We considered the contact stresses in the polyethylene (PE) inserts and articular cartilage, and the force on the collateral ligament, under gait cycle conditions. RESULTS: The contact stress on the PE insert increased as flexion of the femoral component increased, but there was not a remarkable difference in the amount of increased contact stress upon extension. There was no difference in the contact stress on the articular cartilage upon extension of the femoral component, but it increased in flexion during stance and double support periods. The forces on the medial collateral ligaments increased with the extension and decreased with the flexion of the femoral component, whereas the forces on the lateral collateral ligaments showed opposite trends. CONCLUSIONS: Surgeons should be concerned with femoral component position on UKA not only in frontal plane but also in the sagittal plane, because flexion or extension of the femoral component may impact the PE or opposite compartment along with the surrounding ligaments around knee joint.
引用
收藏
页码:171 / 182
页数:12
相关论文
共 48 条
[1]  
[Anonymous], 2002, 142431 ISO
[2]   The Anatomy of the Medial Patellofemoral Ligament [J].
Baldwin, James L. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (12) :2355-2361
[3]   Accuracy and early outcomes in medial unicompartmental knee arthroplasty performed using patient specific instrumentation [J].
Bell, Stuart W. ;
Stoddard, James ;
Bennett, Caroline ;
London, Nicholas J. .
KNEE, 2014, 21 :S33-S36
[4]   Validation of a three-dimensional model of the knee [J].
Blankevoort, L ;
Huiskes, R .
JOURNAL OF BIOMECHANICS, 1996, 29 (07) :955-961
[5]   Anatomy and Biomechanics of the Posterior Cruciate Ligament, Medial and Lateral Sides of the Knee [J].
Bowman, Karl F., Jr. ;
Sekiya, Jon K. .
SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2010, 18 (04) :222-229
[6]  
CARR A, 1993, CLIN ORTHOP RELAT R, P205
[7]   Minimally Invasive Robotic-Arm-Guided Unicompartmental Knee Arthroplasty [J].
Conditt, Michael A. ;
Roche, Martin W. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A :63-68
[8]   How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint [J].
Donahue, TLH ;
Hull, ML ;
Rashid, MM ;
Jacobs, CR .
JOURNAL OF BIOMECHANICS, 2003, 36 (01) :19-34
[9]   Implant position in knee surgery - A comparison of minimally invasive, open unicompartmental and total knee arthroplasty [J].
Fisher, DA ;
Watts, M ;
Davis, KE .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :2-8
[10]   Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis [J].
Godest, AC ;
Beaugonin, M ;
Haug, E ;
Taylor, M ;
Gregson, PJ .
JOURNAL OF BIOMECHANICS, 2002, 35 (02) :267-275