Experimental behaviour of RACFST stub columns after exposed to high temperatures

被引:59
作者
Yang, Y. F. [1 ]
Hou, R. [2 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian, Peoples R China
[2] Liaoning Prov Bldg Design & Res Inst, Shenyang, Peoples R China
基金
中国国家自然科学基金;
关键词
Recycled aggregate concrete-filled steel tube (RACFST); Stub columns; High temperatures; Ultimate strength; Elastic modulus; STEEL TUBULAR COLUMNS; FLEXURAL BEHAVIOR; CONCRETE; TUBES; LOADINGS; FIRE;
D O I
10.1016/j.tws.2012.04.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The experimental studies on the behaviour of recycled aggregate concrete-filled steel tube (RACFST) stub columns after exposed to high temperatures are reported in this paper. Forty specimens, including 32 RACFST stub columns and 8 normal concrete-filled steel tube (CFST) stub columns as reference, were tested, and the failure pattern, load versus strain relation and ultimate strength of the specimens were presented and analysed. Five types of concrete were produced: one reference concrete with natural aggregates, two concrete mixes with recycled coarse aggregate (RCA) replacement ratios of 50% and 100%, and two concrete mixes with recycled fine aggregate (RFA) replacement ratios of 50% and 100%. The specimens were exposed to 300 degrees C, 600 degrees C and 800 degrees C for 3 h. The test results showed that, due to the existence of the recycled aggregates, the post-fire performance of RACFST stub columns was lower than the corresponding normal CFST specimens under the same maximum temperature suffered, and the RACFST specimens with RCA had a better behaviour than those with RFA under the same recycled aggregate replacement ratio. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 19 条
[1]  
[Anonymous], 2011, GB/T 14685-2011
[2]  
Guo Z., 2003, BEHAV REINFORCED CON
[3]  
HAN L.H., 2007, Concrete-filled steel tubular structure-Theory and Practice
[4]   Compressive and flexural behaviour of concrete filled steel tubes after exposure to standard fire [J].
Han, LH ;
Huo, JS ;
Wang, YC .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (07) :882-901
[5]  
Hansen T.C., 1992, 37DRC RILEM TC
[6]   Behaviour of Repaired Concrete Filled Steel Tubular Column to Steel Beam Joints after Exposure to Fire [J].
Huo, Jing-Si ;
Han, Lin-Hai ;
Wang, Yong-Chang .
ADVANCES IN STRUCTURAL ENGINEERING, 2010, 13 (01) :53-67
[7]  
ISO, 1975, International Standard ISO 834
[8]  
Linhai Han., 2002, Advances in Structural Engineering-An International Journal, V5, P123, DOI DOI 10.1260/1369433021502614
[9]  
Mohanraj EK, 2008, PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON THE CONCRETE FUTURE, P319
[10]   Performance of CFST column to steel beam joints subjected to simulated fire including the cooling phase [J].
Song, Tian-Yi ;
Han, Lin-Hai ;
Uy, Brian .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (04) :591-604