Simplified methods for coincidence summing corrections in HPGe efficiency calibration

被引:3
|
作者
Mauring, Alexander [1 ]
Drefvelin, Jon [1 ]
机构
[1] Norwegian Radiat Protect Author, N-1332 Osteras, Norway
关键词
Gamma spectrometry; Coincidence summing; HPGe detectors; n-Type; Detector efficiency; GAMMA-RAY SPECTROMETRY; DECAY;
D O I
10.1016/j.apradiso.2012.02.086
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Simple and practical coincidence summing corrections for n-type HPGe detectors are presented for the common calibration nuclides Co-57 and Co-60 using a defined "virtual peak" and accounting for the summing of gamma photons with x-rays having energies up to 40 key (Y-88 and Ce-139). These corrections make it possible to easily and effectively establish peak and total efficiency curves suitable for subsequent summing corrections in routine gamma spectrometry analyses. Experimental verification of the methods shows excellent agreement for measurements of different reference solutions. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2161 / 2163
页数:3
相关论文
共 50 条
  • [41] Coincidence summing corrections using PENELOPE/PENNUC Monte Carlo code for volume sources of different densities
    Salpadimos, N.
    Karfopoulos, K.
    Potiriadis, C.
    Seimenis, I.
    APPLIED RADIATION AND ISOTOPES, 2023, 192
  • [42] Efficiency transfer in the calibration of a coaxial p-type HpGe detector using the Monte Carlo method
    Vargas, MJ
    Díaz, NC
    Sánchez, DP
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (06) : 707 - 712
  • [43] Efficiency calibration of a HPGe detector in the [46.54-2000] keV energy range for the measurement of environmental samples
    Daza, MJ
    Quintana, B
    García-Talavera, M
    Fernández, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 470 (03) : 520 - 532
  • [44] Efficiency calibration of an HPGe X-ray detector for quantitative PIXE analysis
    Mulware, Stephen J.
    Baxley, Jacob D.
    Rout, Bibhudutta
    Reinert, Tilo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 332 : 95 - 98
  • [45] Coincidence summing corrections factors calculated for volume 152Eu sources in γ-ray spectromtery using Monte Carlo techniques
    Taibi, A.
    Ishak-Boushaki, G. Medkour
    Idiri, Z.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 324 (02) : 687 - 696
  • [46] A semi-empirical method for efficiency calibration of an HPGe detector against different sample densities
    Nabil, Islam M.
    El-Kourghly, K. M.
    El Sayed, A. F.
    APPLIED RADIATION AND ISOTOPES, 2023, 200
  • [47] A practical method for determining γ-ray full-energy peak efficiency considering coincidence-summing and self-absorption corrections for the measurement of environmental samples after the Fukushima reactor accident
    Shizuma, Kiyoshi
    Oba, Yurika
    Takada, Momo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 383 : 183 - 190
  • [48] An investigation of HPGe gamma efficiency calibration software (ANGLE V.3) for applications in nuclear decommissioning
    Bell, S. J.
    Judge, S. M.
    Regan, P. H.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (12) : 2737 - 2741
  • [49] Geant4 Tracks of NaI Cubic Detector Peak Efficiency, Including Coincidence Summing Correction for Rectangular Sources
    Elsafi, Mohamed
    Alzahrani, Jamila S.
    Abbas, Mahmoud I.
    Gouda, Mona M.
    Thabet, Abouzeid A.
    Badawi, Mohamed S.
    El-Khatib, Ahmed M.
    NUCLEAR SCIENCE AND ENGINEERING, 2021, 195 (09) : 1008 - 1016
  • [50] Experimental validation of corrections factors for γ–γ and γ–X coincidence summing of 133Ba, 152Eu, and 125Sb in volume sources
    S. Jonsson
    J. Kastlander
    T. Vidmar
    H. Ramebäck
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 323 : 465 - 472