Simplified methods for coincidence summing corrections in HPGe efficiency calibration

被引:3
|
作者
Mauring, Alexander [1 ]
Drefvelin, Jon [1 ]
机构
[1] Norwegian Radiat Protect Author, N-1332 Osteras, Norway
关键词
Gamma spectrometry; Coincidence summing; HPGe detectors; n-Type; Detector efficiency; GAMMA-RAY SPECTROMETRY; DECAY;
D O I
10.1016/j.apradiso.2012.02.086
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Simple and practical coincidence summing corrections for n-type HPGe detectors are presented for the common calibration nuclides Co-57 and Co-60 using a defined "virtual peak" and accounting for the summing of gamma photons with x-rays having energies up to 40 key (Y-88 and Ce-139). These corrections make it possible to easily and effectively establish peak and total efficiency curves suitable for subsequent summing corrections in routine gamma spectrometry analyses. Experimental verification of the methods shows excellent agreement for measurements of different reference solutions. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2161 / 2163
页数:3
相关论文
共 50 条
  • [31] Simplified efficiency calibration methods for scintillation detectors used in nuclear remediation
    Golovko, Victor V.
    JOURNAL OF CLEANER PRODUCTION, 2024, 478
  • [32] HPGe detector photopeak efficiency calculation including self-absorption and coincidence corrections for cylindrical sources using compact analytical expressions
    Abbas, MI
    Selim, YS
    Bassiouni, M
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 429 - 431
  • [33] Calculation of coincidence summing corrections for X-ray peaks and for sum peaks with X-ray contributions
    Arnold, Dirk
    Sima, Octavian
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1297 - 1302
  • [34] Experimental assessment of the coincidence summing corrections in gamma-ray spectrometry of bulk samples
    Boshkova, T.
    APPLIED RADIATION AND ISOTOPES, 2014, 83 : 1 - 7
  • [35] Accurate computation of coincidence summing corrections in low level gamma-ray spectrometry
    Sima, O
    Arnold, D
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 51 - 56
  • [36] A simple method for efficiency calibration of HPGe detectors in γ-spectrometric measurements
    Pérez-Moreno, JP
    Bolívar, JP
    García-Tenorio, R
    Miguel, ES
    Aguado, JL
    Mas, JL
    Vaca, F
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 437 - 438
  • [37] Monte Carlo calculation of the efficiency calibration curve for HPGe detectors
    Bhattacharya, Tam
    Nagaiah, N.
    Reddy, B. Ram Mohan
    Sharma, P. K.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2018, 56 (08) : 628 - 630
  • [38] Monte Carlo calculations of coincidence-summing corrections for volume sources in gamma-ray spectrometry with Ge detectors
    García-Toraño, E
    Pozuelo, M
    Salvat, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 544 (03) : 577 - 583
  • [39] Consistency test of coincidence-summing calculation methods for extended sources
    Sima, O.
    Ott, A. De Vismes
    Dias, M. S.
    Dryak, P.
    Ferreux, L.
    Gurau, D.
    Hurtado, S.
    Jodlowski, P.
    Karfopoulos, K.
    Koskinas, M. F.
    Laubenstein, M.
    Lee, Y. K.
    Lepy, M. C.
    Luca, A.
    Menezes, M. O.
    Moreira, D. S.
    Nikolic, J.
    Peyres, V.
    Saganowski, P.
    Savva, M. I.
    Senunler, R.
    Solc, J.
    Thanh, T. T.
    Tyminska, K.
    Tyminski, Z.
    Vidmar, T.
    Vukanac, I.
    Yucel, H.
    APPLIED RADIATION AND ISOTOPES, 2020, 155
  • [40] Efficiency calibration and coincidence summing correction for a large volume (946 cm3) LaBr3(Ce) detector: GEANT4 simulations and experimental measurements
    Dhibar, M.
    Mankad, D.
    Mazumdar, I.
    Kumar, G. Anil
    APPLIED RADIATION AND ISOTOPES, 2016, 118 : 32 - 37