Impact of time on ultrasonic cavitation peening via detection of surface plastic deformation

被引:31
作者
Bai, Fushi [1 ]
Saalbach, Kai-Alexander [1 ]
Wang, Liang [1 ,2 ]
Wang, Xiaogeng [1 ]
Twiefel, Jens [1 ]
机构
[1] Leibniz Univ Hannover, Inst Dynam & Vibrat Res, Appelstr 11, D-30167 Hannover, Germany
[2] Nanjing Univ Aeronaut & Astronaut, State Key Lab Mech & Control Mech Struct, Yudao 29, Nanjing 210016, Jiangsu, Peoples R China
关键词
Ultrasonic cavitation peening; Plastic deformation; Microhardness; Roughness; TRANSDUCER;
D O I
10.1016/j.ultras.2017.12.001
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
During ultrasonic cavitation peening, bubbles repeatedly form and collapse, which leads to high impact loads on the treated surface. At the initial stage of ultrasonic cavitation peening, the most obvious change is plastic deformation instead of mass loss on the treated specimen surface. Meanwhile the plastic deformation is beneficial for mechanical surface properties. As the cavitation exposure time increases, erosion and damage are inflicted on the metal surface due to the increase in the number of collapse events. In this respect, the treatment time is a key parameter to improve the specimen surface properties during this manufacturing process. However, the influence of treatment time on the surface properties has not yet been thoroughly investigated. In this paper, it is the first time to utilize the plastic deformation to evaluate the optimal treatment time at different input power. The plastic deformation can be deduced by the mass loss and the volume change on the treated specimen surface. Using plastic deformation, the modification of surface hardness and roughness are investigated at different cavitation exposure intervals and vibration amplitudes. It is found that significant improvement of the microhardness on the treated surface occurs at the end of incubation period. Higher vibration amplitudes of the horn tip lead to shorter incubation period and higher microhardness. (C) 2017 Elsevier B. V. All rights reserved.
引用
收藏
页码:350 / 355
页数:6
相关论文
共 24 条
[1]   Capability evaluation of ultrasonic cavitation peening at different standoff distances [J].
Bai, Fushi ;
Saalbach, Kai-Alexander ;
Long, Yangyang ;
Twiefel, Jens ;
Wallaschek, Joerg .
ULTRASONICS, 2018, 84 :38-44
[2]   Effect of different standoff distance and driving current on transducer during ultrasonic cavitation peening [J].
Bai, Fushi ;
Saalbach, Kai-Alexander ;
Twiefel, Jens ;
Wallaschek, Jorg .
SENSORS AND ACTUATORS A-PHYSICAL, 2017, 261 :274-279
[3]  
Gao Y., 2014, J MANUF SCI E-T ASME, V136, P1
[4]   3D FEM analyses on flow field characteristics of the valveless piezoelectric pump [J].
Huang Jun ;
Zhang Jianhui ;
Shi Weidong ;
Wang Yuan .
CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2016, 29 (04) :825-831
[5]   Model-Based Feedback Control of an Ultrasonic Transducer for Ultrasonic Assisted Turning Using a Novel Digital Controller [J].
Ille, Igor ;
Twiefel, Jens .
Proceedings of the 2015 ICU International Congress on Ultrasonics, 2015, 70 :63-67
[6]   Peening the tip of a notch using ultrasonic cavitation [J].
Jung, Sunghwan ;
Prabhu, Murugesan ;
Lee, Hyungyil .
ULTRASONICS, 2018, 82 :322-326
[7]  
Kim K.-H., 2014, Advanced experimental and numerical techniques for cavitation erosion prediction, V106
[8]   Effects of Temperature and Amplitude on Damage Behavior of Al Alloy by Ultrasonic Vibration Cavitation [J].
Kim, Seong-Jong ;
Jeong, Jae-Yong ;
Lee, Seung-Jun .
SCIENCE OF ADVANCED MATERIALS, 2014, 6 (10) :2185-2190
[9]   Critical analysis of processes and apparatus for industrial surface peening technologies [J].
Kulekci, Mustafa Kemal ;
Esme, Ugur .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2014, 74 (9-12) :1551-1565
[10]  
MATHIAS M, 1991, WEAR, V150, P11, DOI 10.1016/0043-1648(91)90302-B