Effects of improved home heating on asthma in community dwelling children:: randomised controlled trial

被引:165
作者
Howden-Chapman, Philippa [1 ]
Pierse, Nevil [1 ]
Nicholls, Sarah [1 ]
Gillespie-Bennett, Julie [1 ]
Viggers, Helen [1 ]
Cunningham, Malcolm [2 ]
Phipps, Robyn [3 ]
Boulic, Mikael [3 ]
Fjallstrom, Par [3 ]
Free, Sarah [1 ]
Chapman, Ralph [4 ]
Lloyd, Bob [5 ]
Wickens, Kristin [6 ]
Shields, David [1 ]
Baker, Michael [1 ]
Cunningham, Chris [7 ]
Woodward, Alistair [8 ]
Bullen, Chris [8 ]
Crane, Julian [1 ]
机构
[1] Univ Otago, He Kainga Oranga Housing & Hlth Res Programme, Wellington, New Zealand
[2] BRANZ, Porirua City, New Zealand
[3] Massey Univ, Sch Engn & Adv Technol, Palmerston North, New Zealand
[4] Victoria Univ, Sch Geog Environm & Earth Sci, Wellington, New Zealand
[5] Univ Otago, Dept Phys, Dunedin, New Zealand
[6] Univ Otago, Wellington Asthma Res Grp, Wellington, New Zealand
[7] Massey Univ, Res Ctr Maori Hlth & Dev, Wellington, New Zealand
[8] Univ Auckland, Sch Populat Hlth, Auckland 1, New Zealand
来源
BMJ-BRITISH MEDICAL JOURNAL | 2008年 / 337卷 / 7674期
关键词
D O I
10.1136/bmj.a1411
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To assess whether non- polluting, more effective home heating (heat pump, wood pellet burner, flued gas) has a positive effect on the health of children with asthma. Design Randomised controlled trial. Setting Households in five communities in New Zealand. Participants 409 children aged 6- 12 years with doctor diagnosed asthma. Interventions Installation of a non- polluting, more effective home heater before winter. The control group received a replacement heater at the end of the trial. Main outcome measures The primary outcome was change in lung function ( peak expiratory flow rate and forced expiratory volume in one second, FEV1). Secondary outcomes were child reported respiratory tract symptoms and daily use of preventer and reliever drugs. At the end of winter 2005 ( baseline) and winter 2006 ( follow- up) parents reported their child's general health, use of health services, overall respiratory health, and housing conditions. Nitrogen dioxide levels were measured monthly for four months and temperatures in the living room and child's bedroom were recorded hourly. Results Improvements in lung function were not significant ( difference in mean FEV1 130.7 ml, 95% confidence interval - 20.3 to 281.7). Compared with children in the control group, however, children in the intervention group had 1.80 fewer days off school ( 95% confidence interval 0.11 to 3.13), 0.40 fewer visits to a doctor for asthma ( 0.11 to 0.62), and 0.25 fewer visits to a pharmacist for asthma ( 0.09 to 0.32). Children in the intervention group also had fewer reports of poor health ( adjusted odds ratio 0.48, 95% confidence interval 0.31 to 0.74), less sleep disturbed by wheezing ( 0.55, 0.35 to 0.85), less dry cough at night ( 0.52, 0.32 to 0.83), and reduced scores for lower respiratory tract symptoms( 0.77, 0.73 to 0.81) than children in the control group. The intervention was associated with a mean temperature rise in the living room of 1.10 degrees C ( 95% confidence interval 0.54 to 1.64 degrees C) and in the child's bedroom of 0.57 degrees C ( 0.05 degrees C to 1.08 degrees C). Lower levels of nitrogen dioxide were measured in the living rooms of the intervention households than in those of the control households ( geometric mean 8.5 mu/m(3)v 15.7 mu/m(3), P< 0.001). A similar effect was found in the children's bedrooms ( 7.3 mu g m(3)v 10.9 mu g/m(3), P< 0.001). Conclusion Installing non- polluting, more effective heating in the homes of children with asthma did not significantly improve lung function but did significantly reduce symptoms of asthma, days off school, healthcare utilisation, and visits to a pharmacist. Trial registration Clinical Trials NCT00489762.
引用
收藏
页码:852 / 855
页数:9
相关论文
共 47 条
  • [21] The Seattle-King County Healthy Homes Project: Implementation of a comprehensive approach to improving indoor environmental quality for low-income children with asthma
    Krieger, J
    Takaro, TK
    Allen, C
    Song, L
    Weaver, M
    Chai, S
    Dickey, P
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 : 311 - 322
  • [22] Association between asthma control in children and loss of workdays by caregivers
    Laforest, L
    Yin, D
    Kocevar, VS
    Pacheco, Y
    Dickson, N
    Gormand, F
    Van Ganse, E
    [J]. ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2004, 93 (03) : 265 - 271
  • [23] Inhalation transfer factors for air pollution health risk assessment
    Lai, ACK
    Thatcher, TL
    Nazaroff, WW
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (09): : 1688 - 1699
  • [24] RANDOM-EFFECTS MODELS FOR LONGITUDINAL DATA
    LAIRD, NM
    WARE, JH
    [J]. BIOMETRICS, 1982, 38 (04) : 963 - 974
  • [25] The efficacy of an energy efficient upgrade program in New Zealand
    Lloyd, C. R.
    Callau, M. F.
    Bishop, T.
    Smith, I. J.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (07) : 1228 - 1239
  • [26] MACKENZIE I, 2000, CUTTING COST COLD AF, P155
  • [27] Ministry of Health, 2004, ETHN DAT PROT HLTH D
  • [28] Moran SE, 1999, CLIN EXP ALLERGY, V29, P1033, DOI 10.1046/j.1365-2222.1999.00561.x
  • [29] *NAT AC I MED, 2004, DAMP IND SPAC HLTH
  • [30] ONO M, 1989, J JAPAN SOC AIR POLL, V24, P90