Utilization of Underbuilt Shield Wires to Improve the Lightning Performance of Overhead Distribution Lines Hit by Direct Strokes

被引:20
作者
Araneo, Rodolfo [1 ]
Andreotti, Amedeo [3 ]
Brandao Faria, Jose [2 ]
Celozzi, Salvatore [1 ]
Assante, Dario [4 ]
Verolino, Luigi [3 ]
机构
[1] Univ Rome Sapienza, DIAEE, Elect Engn Div, I-00184 Rome, Italy
[2] Univ Lisbon, Inst Super Tecn, Inst Telecomunicacos, P-1049001 Lisbon, Portugal
[3] Univ Federico II Napoli, Dept Elect Engn, I-80125 Naples, Italy
[4] UTIU, Int Telemat Univ Uninettuno, I-00186 Rome, Italy
关键词
Conductors; Grounding; Wires; Lightning; Surges; Insulators; Impedance; chain matrix; multiconductor lines; overhead distribution lines; periodic grounding; shield wires; underbuilt wires; TRANSMISSION-LINES; INDUCED VOLTAGES; GROUND WIRES;
D O I
10.1109/TPWRD.2019.2949505
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The improvement of the lightning performance of overhead distribution lines, hit by direct strokes, is investigated considering the use of additional shield wires beneath the phase conductors. The frequency-domain theory of multiconductor transmission lines with periodical grounding is adopted permitting a rigorous evaluation of the phase and shield wire currents and of the overvoltages across insulators. These can be minimized by careful positioning of the underbuilt shield wires. A sensitivity analysis on the overvoltages is conducted by varying either the position of the underbuilt shield wires and the grounding impedance.
引用
收藏
页码:1656 / 1666
页数:11
相关论文
共 39 条
[1]  
Anderson R.B., 1980, ELECTRA, V69, P65
[2]   Some integrals involving Heidler's lightning return stroke current expression [J].
Andreotti, A ;
Falco, S ;
Verolino, L .
ELECTRICAL ENGINEERING, 2005, 87 (03) :121-128
[3]   Characteristic Impedance of Periodically Grounded Lossless Multiconductor Transmission Lines and Time-Domain Equivalent Representation [J].
Andreotti, Amedeo ;
Assante, Dario ;
Verolino, Luigi .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2014, 56 (01) :221-230
[4]  
[Anonymous], 1997, IEEE Std 112-1996, P1
[5]  
[Anonymous], 18 INT C ENV EL ENG
[6]  
[Anonymous], 2011, IEEE Std 1241-2010 (Revision of IEEE Std 1241-2000, P1, DOI [DOI 10.1109/IEEESTD.2011.5960751, DOI 10.1109/IEEESTD.2011.5706451, 10.1109/IEEESTD.2011.5706451]
[7]   Frequency-Domain Analysis of Sectionalized Shield Wires on PLC Transmission Over High-Voltage Lines [J].
Araneo, Rodolfo ;
Marinho Brandao Faria, J. A. ;
Celozzi, Salvatore .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2017, 59 (03) :853-861
[8]   Transient behavior of wind towers grounding systems under lightning strikes [J].
Araneo R. ;
Celozzi S. .
International Journal of Energy and Environmental Engineering, 2016, 7 (02) :235-247
[9]   Time-Domain Analysis of Building Shielding Against Lightning Electromagnetic Fields [J].
Araneo, Rodolfo ;
Celozzi, Salvatore ;
Tatematsu, Akiyhoshi ;
Rachidi, Farhad .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2015, 57 (03) :397-404
[10]  
Arany R.R., 2017, 2017 17 INT C ENV EL, P1, DOI DOI 10.1109/EMCEUROPE.2017.8094662