Handheld simultaneous scanning laser ophthalmoscopy and optical coherence tomography system

被引:63
作者
LaRocca, Francesco [1 ]
Nankivil, Derek [1 ]
Farsiu, Sina [1 ,2 ]
Izatt, Joseph A. [1 ,2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Med Ctr, Dept Ophthalmol, Durham, NC 27710 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2013年 / 4卷 / 11期
关键词
TARGETED STIMULUS DELIVERY; ADAPTIVE OPTICS; MOTION CORRECTION; CONE PHOTORECEPTORS; IMAGE REGISTRATION; FOVEAL MORPHOLOGY; TRACKING SLO; OCT;
D O I
10.1364/BOE.4.002307
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) are widely used retinal imaging modalities that can assist in the diagnosis of retinal pathologies. The combination of SLO and OCT provides a more comprehensive imaging system and a method to register OCT images to produce motion corrected retinal volumes. While high quality, bench-top SLO-OCT systems have been discussed in the literature and are available commercially, there are currently no handheld designs. We describe the first design and fabrication of a handheld SLO/spectral domain OCT probe. SLO and OCT images were acquired simultaneously with a combined power under the ANSI limit. High signal-to-noise ratio SLO and OCT images were acquired simultaneously from a normal subject with visible motion artifacts. Fully automated motion estimation methods were performed in post-processing to correct for the inter-and intra-frame motion in SLO images and their concurrently acquired OCT volumes. The resulting set of reconstructed SLO images and the OCT volume were without visible motion artifacts. At a reduced field of view, the SLO resolved parafoveal cones without adaptive optics at a retinal eccentricity of 11 in subjects with good ocular optics. This system may be especially useful for imaging young children and subjects with less stable fixation. (C) 2013 Optical Society of America
引用
收藏
页码:2307 / 2321
页数:15
相关论文
共 50 条
  • [11] Optical Coherence Tomography, Scanning Laser Polarimetry and Confocal Scanning Laser Ophthalmoscopy in Retinal Nerve Fiber Layer Measurements of Glaucoma Patients
    Fanihagh, Farsad
    Kremmer, Stephan
    Anastassiou, Gerasimos
    Schallenberg, Maurice
    Steuhl, Klaus-Peter
    Selbach, Michael
    OPEN OPHTHALMOLOGY JOURNAL, 2015, 9 : 41 - 48
  • [12] Handheld scanning probes for Optical Coherence Tomography: Developments, applications and perspectives
    Duma, V. -F.
    Demian, D.
    Sinescu, C.
    Cernat, R.
    Dobre, G.
    Negrutiu, M. L.
    Topala, F. I.
    Hutiu, Gh.
    Bradu, A.
    Podoleanu, A. Gh.
    HIGH-END MEDICINE BASED ON LASER AND BIOTECHNOLOGIES, 2016, 9670
  • [13] Correlation Between Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography, Confocal Scanning Laser Ophthalmoscopy and Scanning Laser Polarimetry
    Cordeiro, D. V., II
    Kara-Jose, A.
    Tavares, I. M.
    Almeida, E. D., Jr.
    Leite, M. T.
    Santos, C. R. S.
    Hatori Endo, A. T. N.
    Melo, L. A. S., Jr.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [14] Human retinal imaging using visible-light optical coherence tomography guided by scanning laser ophthalmoscopy
    Yi, Ji
    Chen, Siyu
    Shu, Xiao
    Fawzi, Amani A.
    Zhang, Hao F.
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (10): : 3701 - 3713
  • [15] Assessment of beta-zone peripapillary atrophy by optical coherence tomography and scanning laser ophthalmoscopy imaging in glaucoma patients
    Seidensticker, Florian
    Reznicek, Lukas
    Mann, Thomas
    Huebert, Irene
    Kampik, Anselm
    Ulbig, Michael
    Hirneiss, Christoph
    Neubauer, Aljoscha S.
    Kernt, Marcus
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 1233 - 1239
  • [16] Optical Coherence Tomography Artifacts Are Associated With Adaptive Optics Scanning Light Ophthalmoscopy Success in Achromatopsia
    Litts, Katie M.
    Woertz, Erica N.
    Georgiou, Michalis
    Patterson, Emily J.
    Lam, Byron L.
    Fishman, Gerald A.
    Pennesi, Mark E.
    Kay, Christine N.
    Hauswirth, William W.
    Michaelides, Michel
    Carroll, Joseph
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (01): : 1 - 11
  • [17] The influence of axial length on confocal scanning laser ophthalmoscopy and spectral-domain optical coherence tomography size measurements: a pilot study
    Roeck, T.
    Wilhelm, B.
    Bartz-Schmidt, K. U.
    Roeck, D.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (04) : 589 - 593
  • [18] Ocular findings and handheld optical coherence tomography in microcephaly
    Papageorgiou, Eleni
    Lee, Helena
    Proudlock, Frank A.
    Sheth, Viral
    Purohit, Ravi
    Vasudevan, Pradeep
    Gottlob, Irene
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [19] Handheld spectrally encoded coherence tomography and reflectometry for motion-corrected ophthalmic optical coherence tomography and optical coherence tomography angiography
    Malone, Joseph D.
    El-Haddad, Mohamed Tarek
    Yerramreddy, Suhaas S.
    Oguz, Ipek
    Tao, Yuankai K.
    NEUROPHOTONICS, 2019, 6 (04)
  • [20] Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror
    Lu, Chen D.
    Kraus, Martin F.
    Potsaid, Benjamin
    Liu, Jonathan J.
    Choi, WooJhon
    Jayaraman, Vijaysekhar
    Cable, Alex E.
    Hornegger, Joachim
    Duker, Jay S.
    Fujimoto, James G.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 293 - 311