Optimizing Patient-Ventilator Synchrony During Invasive Ventilator Assist in Children and Infants Remains a Difficult Task

被引:40
作者
Vignaux, Laurence [1 ,2 ,6 ]
Grazioli, Serge [3 ]
Piquilloud, Lise [4 ]
Bochaton, Nathalie [3 ]
Karam, Oliver [3 ]
Jaecklin, Thomas [3 ]
Levy-Jamet, Yann [3 ]
Tourneux, Pierre [2 ,5 ]
Jolliet, Philippe [4 ,6 ]
Rimensberger, Peter C. [3 ]
机构
[1] Univ Hosp, Cardioresp Physiotherapy Dept, Geneva, Switzerland
[2] UPJV, Peritox EA INERIS UM101 4284, Amiens, France
[3] Univ Hosp, Neonatal & Pediat Intens Care Unit, Geneva, Switzerland
[4] Univ Lausanne Hosp, Intens Care & Burns Unit, Lausanne, Switzerland
[5] Univ Hosp North, Pediat Intens Care Unit, Amiens, France
[6] Univ Hosp Geneva, Intens Care Unit, Geneva, Switzerland
关键词
assisted ventilation; children; mechanical ventilation; neurally adjusted ventilatory assist; patient-ventilator interaction; pediatrics; pressure support; PRESSURE-SUPPORT VENTILATION; INTENSIVE-CARE UNITS; ACUTE LUNG INJURY; MECHANICAL VENTILATION; ASYNCHRONY; FLOW; COMFORT; NAVA; POPULATION; DIAPHRAGM;
D O I
10.1097/PCC.0b013e31828a8606
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To document and compare the prevalence of asynchrony events during invasive-assisted mechanical ventilation in pressure support mode and in neurally adjusted ventilatory assist in children. Design: Prospective, randomized, and crossover study. Setting: Pediatric and Neonatal Intensive Care Unit, University Hospital of Geneva, Switzerland. Patients: Intubated and mechanically ventilated children, between 4 weeks and 5 years old. Interventions: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support, three levels of expiratory trigger setting were compared: expiratory trigger setting as set by the clinician in charge (PSinit), followed by a 10% (in absolute values) increase and decrease of the clinician's expiratory trigger setting. The pressure support session with the least number of asynchrony events was defined as PSbest. Therefore, three periods were compared: PSinit, PSbest, and neurally adjusted ventilatory assist. Asynchrony events, trigger delay, and inspiratory time in excess were quantified for each of them. Measurements and Main Results: Data from 19 children were analyzed. Main asynchrony events during PSinit were autotriggering (3.6 events/min [0.7-8.2]), ineffective efforts (1.2/min [0.6-5]), and premature cycling (3.5/min [1.3-4.9]). Their number was significantly reduced with PSbest: autotriggering 1.6/min (0.2-4.9), ineffective efforts 0.7/min (0-2.6), and premature cycling 2/min (0.1-3.1), p < 0.005 for each comparison. The median asynchrony index (total number of asynchronies/triggered and not triggered breaths x100) was significantly different between PSinit and PSbest: 37.3% [19-47%] and 29% [24-43%], respectively, p < 0.005). With neurally adjusted ventilatory assist, all types of asynchrony events except double-triggering and inspiratory time in excess were significantly reduced resulting in an asynchrony index of 3.8% (2.4-15%) (p < 0.005 compared to PSbest). Conclusions: Asynchrony events are frequent during pressure support in children despite adjusting the cycling off criteria. Neurally adjusted ventilatory assist allowed for an almost ten-fold reduction in asynchrony events. Further studies should determine the clinical impact of these findings.
引用
收藏
页码:E316 / E325
页数:10
相关论文
共 50 条
  • [1] Optimizing patient-ventilator synchrony
    Epstein, SK
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 22 (02) : 137 - 152
  • [2] Patient-Ventilator Synchrony
    Doerschug, Kevin C.
    CLINICS IN CHEST MEDICINE, 2022, 43 (03) : 511 - 518
  • [3] Neurally adjusted ventilatory assist improves patient-ventilator interaction
    Piquilloud, Lise
    Vignaux, Laurence
    Bialais, Emilie
    Roeseler, Jean
    Sottiaux, Thierry
    Laterre, Pierre-Francois
    Jolliet, Philippe
    Tassaux, Didier
    INTENSIVE CARE MEDICINE, 2011, 37 (02) : 263 - 271
  • [4] Patient-Ventilator Asynchrony During Noninvasive Pressure Support Ventilation and Neurally Adjusted Ventilatory Assist in Infants and Children
    Vignaux, Laurence
    Grazioli, Serge
    Piquilloud, Lise
    Bochaton, Nathalie
    Karam, Oliver
    Levy-Jamet, Yann
    Jaecklin, Thomas
    Tourneux, Pierre
    Jolliet, Philippe
    Rimensberger, Peter C.
    PEDIATRIC CRITICAL CARE MEDICINE, 2013, 14 (08) : E357 - E364
  • [5] Noninvasive Neurally Adjusted Ventilator Assist Ventilation in the Postoperative Period Produces Better Patient-Ventilator Synchrony but Not Comfort
    Harnisch, L. O.
    Olgemoeller, U.
    Mann, J.
    Quintel, M.
    Moerer, O.
    PULMONARY MEDICINE, 2020, 2020
  • [6] Patient-ventilator asynchrony during conventional mechanical ventilation in children
    Mortamet, Guillaume
    Larouche, Alexandrine
    Ducharme-Crevier, Laurence
    Flechelles, Olivier
    Constantin, Gabrielle
    Essouri, Sandrine
    Pellerin-Leblanc, Amelie-Ann
    Beck, Jennifer
    Sinderby, Christer
    Jouvet, Philippe
    Emeriaud, Guillaume
    ANNALS OF INTENSIVE CARE, 2017, 7
  • [7] Patient-ventilator interaction during pressure support ventilation and neurally adjusted ventilatory assist
    Spahija, Jadranka
    de Marchie, Michel
    Albert, Martin
    Bellemare, Patrick
    Delisle, Stephane
    Beck, Jennifer
    Sinderby, Christer
    CRITICAL CARE MEDICINE, 2010, 38 (02) : 518 - 526
  • [8] Patient-Ventilator Asynchrony During Noninvasive Pressure Support Ventilation and Neurally Adjusted Ventilatory Assist in Infants and Children
    Ramet, Jose
    De Dooy, Jozef
    PEDIATRIC CRITICAL CARE MEDICINE, 2013, 14 (07) : 728 - 729
  • [9] Neurally adjusted ventilatory assist (NAVA) improves patient-ventilator interaction during non-invasive ventilation delivered by face mask
    Piquilloud, Lise
    Tassaux, Didier
    Bialais, Emilie
    Lambermont, Bernard
    Sottiaux, Thierry
    Roeseler, Jean
    Laterre, Pierre-Francois
    Jolliet, Philippe
    Revelly, Jean-Pierre
    INTENSIVE CARE MEDICINE, 2012, 38 (10) : 1624 - 1631
  • [10] Trends in Pediatric Patient-Ventilator Asynchrony During Invasive Mechanical Ventilation
    Blokpoel, Robert G. T.
    Burgerhof, Johannes G. M.
    Markhorst, Dick G.
    Kneyber, Martin C. J.
    PEDIATRIC CRITICAL CARE MEDICINE, 2021, 22 (11) : 993 - 997