Simple Scanning Phase-Contrast X-ray Tomography Using Intensity Detectors

被引:3
作者
Takano, Hidekazu [1 ]
Shimomura, Sho [1 ]
Konishi, Shigeki [1 ]
Azuma, Hiroaki [1 ]
Tsusaka, Yoshiyuki [1 ]
Kagoshima, Yasushi [1 ]
机构
[1] Univ Hyogo, Grad Sch Mat Sci, Ctr Novel Mat Sci Multiextreme Condit, Kamigori, Hyogo 6781297, Japan
关键词
MICROSCOPE; RESOLUTION; INTERFEROMETRY;
D O I
10.7567/JJAP.52.040204
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have developed a phase-contrast X-ray microtomography system based on scanning microscopy with X-ray focusing optics. The system is very simple because only two conventional intensity detectors and a half-obstructing-plate for the second detector are installed into the conventional scanning microscopy setup. We constructed the system with a 450-nm-size focused beam of a 10 keV X-ray. The system is operated with a sampling rate of 100 Hz. Adopting data correction using a guide object and data interpolation procedure in sinograms, tomographic reconstruction images with a high spatial resolution and phase sensitivity are obtained. (C) 2013 The Japan Society of Applied Physics
引用
收藏
页数:3
相关论文
共 15 条
  • [1] A characterisation of dark-field imaging of colloidal gold labels in a scanning transmission X-ray microscope
    Chapman, HN
    Jacobsen, C
    Williams, S
    [J]. ULTRAMICROSCOPY, 1996, 62 (03) : 191 - 213
  • [2] Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays
    Cloetens, P
    Ludwig, W
    Baruchel, J
    Van Dyck, D
    Van Landuyt, J
    Guigay, JP
    Schlenker, M
    [J]. APPLIED PHYSICS LETTERS, 1999, 75 (19) : 2912 - 2914
  • [3] Differential phase contrast with a segmented detector in a scanning X-ray microprobe
    Hornberger, B.
    de Jonge, M. D.
    Feser, M.
    Holl, P.
    Holzner, C.
    Jacobsen, C.
    Legnini, D.
    Paterson, D.
    Rehak, P.
    Strueder, L.
    Vogt, S.
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 : 355 - 362
  • [4] Scanning differential-phase-contrast hard X-ray microscopy with wedge absorber detector
    Kagoshima, Y
    Shimose, K
    Koyama, T
    Wada, I
    Saikubo, A
    Hayashi, K
    Tsusaka, Y
    Matsui, J
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2004, 43 (11A): : L1449 - L1451
  • [5] High-spatial-resolution phase measurement by micro-interferometry using a hard X-ray imaging microscope
    Koyama, T
    Kagoshima, Y
    Wada, I
    Saikubo, A
    Shimose, K
    Hayashi, K
    Tsusaka, Y
    Matsui, J
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2004, 43 (3B): : L421 - L423
  • [6] Hard X-ray nano-interferometer and its application to high-spatial-resolution phase tomography
    Koyama, Takahisa
    Tsuji, Takuya
    Yoshida, Keisuke
    Takano, Hidekazu
    Tsusaka, Yoshiyuki
    Kagoshima, Yasushi
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2006, 45 (42-45): : L1159 - L1161
  • [7] Evaluation of the improved three-dimensional resolution of a synchrotron radiation computed tomograph using a micro-fabricated test pattern
    Mizutani, Ryuta
    Takeuchi, Akihisa
    Uesugi, Kentaro
    Suzuki, Yoshio
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 (648-654) : 648 - 654
  • [8] Demonstration of X-Ray Talbot interferometry
    Momose, A
    Kawamoto, S
    Koyama, I
    Hamaishi, Y
    Takai, K
    Suzuki, Y
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (7B): : L866 - L868
  • [9] Phase-contrast X-ray computed tomography for observing biological soft tissues
    Momose, A
    Takeda, T
    Itai, Y
    Hirano, K
    [J]. NATURE MEDICINE, 1996, 2 (04) : 473 - 475
  • [10] Quantitative effective atomic number imaging using simultaneous x-ray absorption and phase shift measurement
    Mukaide, Taihei
    Watanabe, Masatoshi
    Takada, Kazuhiro
    Iida, Atsuo
    Fukuda, Kazunori
    Noma, Takashi
    [J]. APPLIED PHYSICS LETTERS, 2011, 98 (11)