Time-Multiplexing using a Static Full-Ring Multi-Pinhole Collimator for Brain SPECT

被引:0
作者
Van Audenhaege, Karen [1 ]
Vandeghinste, Bert [1 ]
Vandenberghe, Stefaan [1 ]
Van Holen, Roel [1 ]
机构
[1] Ghent Univ iMinds, Dept Elect & Informat Syst, MEDISIP IBiTech, B-9000 Ghent, Belgium
来源
2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC) | 2012年
关键词
Imaging; instrumentation; SPECT; collimator; multiplexing; overlap; pinhole; PROJECTIONS; QUALITY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In clinical practice, brain SPECT is usually performed using a dual-head SPECT scanner with fan-beam or parallel-beam collimators rotating around the patient's head. The resolution of such a system is typically around 8-10 mm. We designed a SPECT system based on a full ring of detectors with a stationary multi-pinhole collimator. The spatial resolution of this brain imaging system is 6 mm. The system is adaptive in the sense that it can be used with different degrees of multiplexing by selecting the number of pinholes that are opened at the same time. The opening and closing of pinholes is controlled with a shutter mechanism. In this study we investigated the potential of combining multiplexed and non-multiplexed data (called time-multiplexing) to increase the sensitivity and the image quality of the system. We simulated and reconstructed a uniform phantom to assess the presence of artifacts, a contrast phantom to quantify the potential improvement in image quality and a Hoffman phantom for visual assessment. We compared different acquisition setups: without multiplexing, with only multiplexing and with time-multiplexing. The reconstructed images with only multiplexed data show severe artifacts. These were reduced by using time-multiplexing and were completely eliminated by using a body support (BS). The simulations of the contrast phantom show an improved image quality for time-multiplexing with BS (5% improvement in CRC at 58% noise compared to non-multiplexed data with BS).
引用
收藏
页码:3097 / 3100
页数:4
相关论文
共 8 条
  • [1] Analytic determination of the resolution-equivalent effective diameter of a pinhole collimator
    Accorsi, R
    Metzler, SD
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (06) : 750 - 763
  • [2] Amen Daniel G, 2011, Open Neuroimag J, V5, P40, DOI 10.2174/1874440001105010040
  • [3] Daube-Witherspoon M E, 2008, IEEE NUCL SCI S, P5463
  • [4] The potential for mixed multiplexed and non-multiplexed data to improve the reconstruction quality of a multi-slit-slat collimator SPECT system
    Mahmood, Shelan T.
    Erlandsson, Kjell
    Cullum, Ian
    Hutton, Brian F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (08) : 2247 - 2268
  • [5] Van Audenhaege K., 2011, IEEE MED IM
  • [6] Resolution recovery in pinhole SPECT based on multi-ray projections: a phantom study
    Vanhove, Christian
    Andreyev, Andriy
    Defrise, Michel
    Nuyts, Johan
    Bossuyt, Axel
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (02) : 170 - 180
  • [7] Effect of overlapping projections on reconstruction image quality in multipinhole SPECT
    Vunckx, Kathleen
    Suetens, Paul
    Nuyts, Johan
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (07) : 972 - 983
  • [8] Optimized Multipinhole Design for Mouse Imaging
    Vunckx, Kathleen
    Nuyts, Johan
    Vanbilloen, Bert
    De Saint-Hubert, Marijke
    Vanderghinste, Dominique
    Rattat, Dirk
    Mottaghy, Felix M.
    Defrise, Michel
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (05) : 2696 - 2705