Carrier element-free coprecipitation (CEFC) method for the separation, preconcentration and speciation of chromium using an isatin derivative

被引:73
作者
Bulut, Volkan Numan [2 ]
Ozdes, Duygu [2 ]
Bekircan, Olcay [2 ]
Gundogdu, Ali [2 ]
Duran, Celal [2 ]
Soylak, Mustafa [1 ]
机构
[1] Erciyes Univ, Fac Arts & Sci, Dept Chem, TR-38039 Kayseri, Turkey
[2] Karadeniz Tech Univ, Dept Chem, Fac Arts & Sci, TR-61080 Trabzon, Turkey
关键词
Chromium speciation; Carrier element-free coprecipitation (CEFC); Isatin derivative; Preconcentration; Flame atomic absorption spectrometry; CLOUD POINT EXTRACTION; SOLID-PHASE EXTRACTION; LIQUID-LIQUID-EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; TRACE-METAL IONS; WATER SAMPLES; HEXAVALENT CHROMIUM; CR(III); CR(VI); BEHAVIOR;
D O I
10.1016/j.aca.2008.10.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, simple, rapid and sensitive separation, preconcentration and speciation procedure for chromium in environmental liquid and solid samples has been established. The present speciation procedure for Cr(III) and Cr(VI) is based on combination of carrier element-free coprecipitation (CEFC) and flame atomic absorption spectrometric (FAAS) determinations. In this method a newly synthesized organic coprecipitant, 5-chloro-3-[4-(trifluoromethoxy) phenylimino]indolin-2-one (CFMEPI), was used without adding any carrier element for coprecipitation of chromium(III). After reduction of chromium(VI) by concentrated H2SO4 and ethanol, the procedure was applied for the determination of total chromium. Chromium(VI) was calculated as the difference between the amount of total chromium and chromium(III). The optimum conditions for coprecipitation and speciation processes were investigated on several commonly tested experimental parameters, such as pH of the solution, amount of coprecipitant, sample volume, etc. No considerable interference was observed from the other investigated anions and cations, which may be found in natural water samples. The preconcentration factor was found to be 40. The detection limit for chromium(III) corresponding to three times the standard deviation of the blank (N = 10) was found 0.7 mu g L-1. The present procedure was successfully applied for speciation of chromium in several liquid and solid environmental samples. In order to support the accuracy of the method, the certified reference materials (CRM-TMDW-500 Drinking Water and CRM-SA-C Sandy Soil C) were analyzed, and standard APDC-MIBK liquid-liquid extraction method was performed. The results obtained were in good agreement with the certified values. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 36 条
  • [1] Evaluation of toxic metals in biological samples (scalp hair, blood and urine) of steel mill workers by electrothermal atomic absorption spectrometry
    Afridi, Hassan I.
    Kazi, Tasneem G.
    Jamali, Mohammad K.
    Kazi, Gul H.
    Arain, Mohammad B.
    Jalbani, Nusrat
    Shar, Ghulam Q.
    Sarfaraz, Raja A.
    [J]. TOXICOLOGY AND INDUSTRIAL HEALTH, 2006, 22 (09) : 381 - 393
  • [2] AYDIN FA, J HAZARD MA IN PRESS
  • [3] Speciation of hexavalent chromium in waters by liquid-liquid extraction and GFAAS determination
    Beni, Aron
    Karosi, Roland
    Posta, Jozsef
    [J]. MICROCHEMICAL JOURNAL, 2007, 85 (01) : 103 - 108
  • [4] A new approach to separation and pre-concentration of some trace metals with co-precipitation method using a triazole
    Bulut, Volkan Numan
    Duran, Celal
    Gundogdu, Ali
    Soylak, Mustafa
    Yildirim, Nuri
    Elci, Latif
    [J]. TALANTA, 2008, 76 (02) : 469 - 474
  • [5] Automation of liquid-liquid extraction-spectrophotometry using prolonged pseudo-liquid drops and handheld CCD for speciation of Cr(VI) and Cr(III) in water samples
    Chen, W
    Zhong, GP
    Zhou, ZD
    Wu, P
    Hou, XD
    [J]. ANALYTICAL SCIENCES, 2005, 21 (10) : 1189 - 1193
  • [6] Speciation of chromium in mineral waters and salinas by solid-phase extraction and graphite furnace atomic absorption spectrometry
    Chwastowska, J
    Skwara, W
    Sterlinska, E
    Pszonicki, L
    [J]. TALANTA, 2005, 66 (05) : 1345 - 1349
  • [7] Electrochemical behaviour of isatin at a glassy carbon electrode
    Diculescu, Victor C.
    Kumbhat, Sunita
    Oliveira-Brett, Ana Maria
    [J]. ANALYTICA CHIMICA ACTA, 2006, 575 (02) : 190 - 197
  • [8] Bi(III)4-methylpiperidinedithiocarbamate coprecipitation procedure for separation-pre-concentration of trace metal ions in water samples by flame atomic absorption spectrometric determination
    Efendioglu, Ayseguel
    Yagan, Mehtap
    Bati, Bekir
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2007, 149 (01) : 160 - 165
  • [9] Greenberg A., 1992, Standard Methods for the Examination of Water and Wastewater, V18, P3
  • [10] Cr(III)/Cr(VI) speciation in water samples by extractive separation using Amberlite CG-50 and final determination by FAAS
    Hosseini, Mohammad S.
    Sarab, Ali R. Rzaei
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2007, 87 (05) : 375 - 385