Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system

被引:12
作者
Lima, JLFC [1 ]
Montenegro, MCBSM [1 ]
Pinto, APMMO [1 ]
机构
[1] Fac Farm, CEQUP, Dept Quim Fis, P-4050 Porto, Portugal
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1999年 / 364卷 / 04期
关键词
D O I
10.1007/s002160051348
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection set-up based on potentiometric detection and gas diffusion device for the determination of total nitrogen in food is described. The detection system consisted of two ammonium-sensitive electrodes placed sequentially and each alternately operating as reference electrode. Tubular electrodes without an inner reference solution were prepared with a PVC membrane composed of nonactin in Tris (2-ethylhexyl) phosphate and potassium tetrakis (4-chlorophenyl) berate to reduce the membrane resistance. The food sample digests were inserted into the system, and the ammonium present was converted into ammonia gas. The gas diffused through a gas-permeable membrane to a buffer acceptor stream with a pH that ensured transformation to the ammonium cation, which was potentiometrically detected. Good agreement between FIA results and those provided by the reference procedure was obtained, with relative deviation errors below 5%. Using the proposed system, low reagent consumption is possible, a sampling rate of about 30 samples/h was achieved, as well as a good reproducibility for consecutive injections of the same sample (variation coefficient < 2%).
引用
收藏
页码:353 / 357
页数:5
相关论文
共 15 条
  • [1] FLOW-THROUGH TUBULAR PVC MATRIX MEMBRANE-ELECTRODE WITHOUT INNER REFERENCE SOLUTION FOR FLOW-INJECTION ANALYSIS
    ALEGRET, S
    ALONSO, J
    BARTROLI, J
    PAULIS, JM
    LIMA, JLFC
    MACHADO, AASC
    [J]. ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) : 147 - 152
  • [2] FLOW-INJECTION SYSTEM FOR ONLINE POTENTIOMETRIC MONITORING OF AMMONIA IN FRESH-WATER STREAMS
    ALEGRET, S
    ALONSO, J
    BARTROLI, J
    MARTINEZFABREGAS, E
    [J]. ANALYST, 1989, 114 (11) : 1443 - 1447
  • [3] ALEGRET S, 1987, QUIM ANAL, V6, P278
  • [4] FLOW-INJECTION ANALYSIS OF HIGH CHLORIDE LEVELS IN ELECTROPLATING BATHS USING ONLINE DIALYSIS AND POTENTIOMETRIC DETECTION
    ARAUJO, AN
    ETXEBARRIA, MB
    LIMA, JLFC
    MONTENEGRO, MCBSM
    OLMOS, RP
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (07): : 614 - 617
  • [5] BUHRER T, 1988, PFLUG ARCH EUR J PHY, V412, P359
  • [6] Potentiometric determination of total nitrogen in soils by flow injection analysis with a gas-diffusion unit
    Ferreira, AMR
    Lima, JLFC
    Rangel, AOSS
    [J]. AUSTRALIAN JOURNAL OF SOIL RESEARCH, 1996, 34 (04): : 503 - 510
  • [7] Helrich K., 1990, ASS OFFICIAL ANAL CH
  • [8] DETERMINATION OF AMMONIA IN LOW CONCENTRATIONS WITH NESSLERS REAGENT BY FLOW INJECTION ANALYSIS
    KRUG, FJ
    RUZICKA, J
    HANSEN, EH
    [J]. ANALYST, 1979, 104 (1234) : 47 - 54
  • [9] FLOW-INJECTION DETERMINATION OF AMMONIA IN KJELDAHL DIGESTS BY GAS-DIFFUSION AND CONDUCTOMETRY
    PASQUINI, C
    DEFARIA, LC
    [J]. ANALYTICA CHIMICA ACTA, 1987, 193 : 19 - 27
  • [10] SCHOLER RP, 1970, CHIMIA, V24, P372