Calculating geometrical margins for hypofractionated radiotherapy

被引:33
作者
Herschtal, A. [1 ,4 ]
Foroudi, F. [2 ]
Silva, L. [1 ]
Gill, S. [2 ]
Kron, T. [3 ]
机构
[1] Peter MacCallum Canc Ctr, Dept Biostat & Clin Trials, Melbourne, Vic, Australia
[2] Peter MacCallum Canc Ctr, Dept Radiat Oncol, Melbourne, Vic, Australia
[3] Peter MacCallum Canc Ctr, Dept Phys Sci, Melbourne, Vic, Australia
[4] Swinburne Univ Technol, Melbourne, Vic, Australia
基金
英国医学研究理事会;
关键词
BODY RADIATION-THERAPY; PROSTATE-CANCER; UNCERTAINTIES; ERRORS; PROBABILITY;
D O I
10.1088/0031-9155/58/2/319
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Formulae to calculate margins for external beam radiotherapy traditionally treat the radiotherapy regimen for analysis purposes as consisting of a very large number of treatment sessions, each delivering a very small dose. It is assumed that the difference in the calculated margin for an infinitely fractionated regimen, and the margin for real world treatment scenarios with finite fractions per patient, is negligible given the usual large number of fractions used to treat most malignancies. However hypofractionated radiotherapy using five fractions or even fewer is becoming increasingly common, causing the accuracy of traditional margin formulae to break down. This work introduces an algorithm that accurately calculates margins for hypofractionated treatment regimens. A method for estimating an upper limit for the required margin is introduced, and an adjustment to the van Herk formula (van Herk et al (2000 Int. J. Radiat. Oncol. Biol. Phys. 47 1121-35)) is used to provide a lower limit. A single-term mathematical model is then used to interpolate between these limits. Results are compared to those calculated by Monte Carlo simulation, demonstrating that the proposed method yields accurate estimates of the actual margin required (consistently within similar to 1%) for wide ranges of values of the systematic error, random error and penumbral width, even when the number of fractions per patient is as low as 2.
引用
收藏
页码:319 / 333
页数:15
相关论文
共 16 条
[1]  
[Anonymous], 2010, R LANG ENV STAT COMP
[2]  
[Anonymous], 2002, Algorithms for Minimization Without Derivatives
[3]   Target margins for random geometrical treatment uncertainties in conformal radiotherapy [J].
Bel, A ;
vanHerk, M ;
Lebesque, JV .
MEDICAL PHYSICS, 1996, 23 (09) :1537-1545
[4]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[5]   A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload [J].
De Boer, HCJ ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1350-1365
[6]   Treating intermediate-risk prostate cancer with hypofractionated external beam radiotherapy alone [J].
Faria, Sergio ;
Dal Pra, Alan ;
Cury, Fabio ;
David, Marc ;
Duclos, Marie ;
Freeman, Carolyn R. ;
Souhami, Luis .
RADIOTHERAPY AND ONCOLOGY, 2011, 101 (03) :486-489
[7]   Study of prostate delineation referenced against a gold standard created from the visible human data [J].
Gao, Zhanrong ;
Wilkin, David ;
Eapen, Libni ;
Morash, Christopher ;
Wassef, Youssef ;
Gerig, Lee .
RADIOTHERAPY AND ONCOLOGY, 2007, 85 (02) :239-246
[8]   Electronic portal imaging vs kilovoltage imaging in fiducial marker image-guided radiotherapy for prostate cancer: an analysis of set-up uncertainties [J].
Gill, S. ;
Thomas, J. ;
Fox, C. ;
Kron, T. ;
Thompson, A. ;
Chander, S. ;
Williams, S. ;
Tai, K. H. ;
Duchesne, G. ;
Foroudi, F. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1010) :176-182
[9]   Convolution method and CTV-to-PTV margins for finite fractions and small systematic errors [J].
Gordon, J. J. ;
Siebers, J. V. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (07) :1967-1990
[10]   Radiotherapy margin design with particular consideration of high curvature CTVs [J].
Herschtal, Alan ;
Kron, Tomas ;
Fox, Chris .
MEDICAL PHYSICS, 2009, 36 (03) :684-697