Single-Event Leak Detection in Pipeline Using First Three Resonant Responses

被引:71
作者
Gong, Jinzhe [1 ]
Lambert, Martin F. [1 ]
Simpson, Angus R. [1 ]
Zecchin, Aaron C. [1 ]
机构
[1] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia
基金
澳大利亚研究理事会;
关键词
Pipelines; Fluid transients; Water hammer; Water distribution systems; Leak detection; Frequency response diagram; Harmonic analysis; UNSTEADY-STATE TESTS; SYSTEM DIAGNOSIS; MANAGEMENT; LOCATION; PIPES;
D O I
10.1061/(ASCE)HY.1943-7900.0000720
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Hydraulic transients (water hammer waves) can be used to excite a pressurized pipeline, yielding the frequency response diagram (FRD) of the system. The FRD of a pipeline system is useful for condition assessment and fault detection, because it is closely related to the physical properties of the pipeline. Most previous FRD-based leak detection techniques use the sinusoidal leak-induced pattern recorded on the FRD, either shown on the resonant responses or the antiresonant responses. In contrast, the technique reported in the current paper only uses the responses at the first three resonant frequencies to determine the location and size of a leak. The bandwidth of the excitation only needs to be five times that of the fundamental frequency of the tested pipeline, which is much less than the requirement in conventional FRD-based techniques. Sensitivity analysis and numerical simulations are performed to assess the robustness and applicable range of the proposed leak location technique. The proposed leak location technique is verified by both numerical simulations and by using an experimental FRD obtained from a laboratory pipeline. (C) 2013 American Society of Civil Engineers.
引用
收藏
页码:645 / 655
页数:11
相关论文
共 34 条
[1]  
Beuken R. H. S., 2006, P WAT DISTR SYST AN
[2]   Transient test-based technique for leak detection in outfall pipes [J].
Brunone, B .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 1999, 125 (05) :302-306
[3]  
Chaudhry M., 1987, APPL HYDRAULIC TRANS
[4]   How severe can transients be after a sudden depressurization? [J].
Collins, Richard P. ;
Boxall, Joby B. ;
Karney, Bryan W. ;
Brunone, Bruno ;
Meniconi, Silvia .
JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2012, 104 (04) :67-68
[5]   Energy and costs of leaky pipes: Toward comprehensive picture [J].
Colombo, AF ;
Karney, BW .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 2002, 128 (06) :441-450
[6]   A selective literature review of transient-based leak detection methods [J].
Colombo, Andrew F. ;
Lee, Pedro ;
Karney, Bryan W. .
JOURNAL OF HYDRO-ENVIRONMENT RESEARCH, 2009, 2 (04) :212-227
[7]   Standing wave difference method for leak detection in pipeline systems [J].
Covas, D ;
Ramos, H ;
de Almeida, AB .
JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2005, 131 (12) :1106-1116
[8]   Leak detection in complex series pipelines by using the system frequency response method [J].
Duan, Huan-Feng ;
Lee, Pedro J. ;
Ghidaoui, Mohamed S. ;
Tung, Yeou-Koung .
JOURNAL OF HYDRAULIC RESEARCH, 2011, 49 (02) :213-221
[9]  
Eiswirth M., 2001, P 4 INT C WAT PIP SY, P137
[10]   Pipe system diagnosis and leak detection by unsteady-state tests. 1. Harmonic analysis [J].
Ferrante, M ;
Brunone, B .
ADVANCES IN WATER RESOURCES, 2003, 26 (01) :95-105