Dynamic hip screw with stabilization plate in unstable intertrochanteric fractures: a case series

被引:0
|
作者
Lotfy, Sherif Adel [1 ]
El Nor, Tarek Abo [1 ]
Romeih, Mohamed [1 ]
机构
[1] Tanta Univ, Dept Orthoped Surg, 10th El Madina El Monawara St, Tanta, Gharbya, Egypt
来源
CURRENT ORTHOPAEDIC PRACTICE | 2022年 / 33卷 / 06期
关键词
unstable intertrochanteric fracture; dynamic hip screw; trochanteric stabilization plate; and cephalomedullary nail; TIP-APEX DISTANCE; QUALITY-OF-LIFE; PERITROCHANTERIC FRACTURES; TROCHANTERIC FRACTURES; FEMORAL FRACTURES; FIXATION; MORTALITY; FAILURE; NAIL;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unstable intertrochanteric fractures represent about 60% of all trochanteric fractures. Dynamic hip screw alone in an unstable fracture pattern has a high failure rate of about 50%. Proximal femoral nail is technically a difficult surgery and has complications including nail failure, femoral shaft fracture, malreduction, screw cut-out, and nonunion. Putting a buttress like a trochantericstabilization plate acts as a support to the dynamic hip screw and gives good lateral wall buttress, which prevents excessive shaft medialization. Methods: Twenty-one patients with closed unstable trochanteric fractures were treated by dynamic hip screw with trochanteric stabilization plate. Results: According to the modified Harris Hip Scoring system, 11 patients had excellent results, five patients had good results, four patients had fair results, and one patient had a poor result. Conclusions: The dynamic hip screw with trochanteric stabilization plate provides a stable construct for unstable intertrochanteric fractures as it gives a good lateral wall buttress which prevents excessive fracture collapse, femoral shaft medialization, and consecutive limb shortening. It effectively supports the unstable greater trochanteric fragment and can maintain the lever arm with adequate abductor strength.
引用
收藏
页码:530 / 537
页数:8
相关论文
共 50 条
  • [31] A comparison of hemiarthroplasty versus dynamic hip screw fixation for intertrochanteric femoral fractures: a systematic review
    Chowdhury, Alex K.
    Townsend, Oliver
    Edwards, Max R.
    HIP INTERNATIONAL, 2023, 33 (04) : 752 - 761
  • [32] Is the Best Plate a Nail? A Review of 3230 Unstable Intertrochanteric Fractures of the Proximal Femur
    Tucker, Adam
    Donnelly, Kevin J.
    Rowan, Clare
    McDonald, Sinead
    Foster, Andrew P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (02) : 53 - 60
  • [33] Intraoperative lateral wall fractures during Dynamic Hip Screw fixation for intertrochanteric fractures-Incidence, causative factors and clinical outcome
    Pradeep, Annur R.
    KiranKumar, Addala
    Dheenadhayalan, Jayaramaraju
    Rajasekaran, Shanmuganathan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (02): : 334 - 338
  • [34] Functional and Radiological Outcome of Unstable Intertrochanteric Fracture Post Dynamic Hip Screw Fixation
    Lakho, Muhammad T.
    Jatoi, Asif A.
    Azfar, Muhammad Khanzada
    Ali, Aijaz
    Javed, Safiya
    Bhatti, Anisuddin
    Karim, Musa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [35] Optimizing fixation methods for stable and unstable intertrochanteric hip fractures treated with sliding hip screw or cephalomedullary nailing: A comparative biomechanical and finite element analysis study
    Kyriakopoulos, G.
    Panagopoulos, A.
    Pasiou, E.
    Kourkoulis, S. K.
    Diamantakos, I.
    Anastopoulos, G.
    Tserpes, K.
    Tatani, I.
    Lakoumentas, J.
    Megas, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (12): : 4072 - 4085
  • [36] Integrated risk scoring model for predicting dynamic hip screw treatment outcome of intertrochanteric fracture
    Hsu, Cheng-En
    Huang, Kui-Chou
    Lin, Tzu-Chieh
    Tong, Kwok-Man
    Lee, Mei-Hsuan
    Chiu, Yung-Cheng
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (11): : 2501 - 2506
  • [37] Comparison of functional outcomes in patients fixed with dynamic hip screw and proximal femur nail-anti-rotation in A1 and A2 type intertrochanteric femur fractures
    Sevinc, Huseyin Fatih
    Cirpar, Meric
    Canbeyli, Ibrahim Deniz
    Daglar, Bulent
    Oktas, Birhan
    Durusoy, Serhat
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2020, 26 (05): : 811 - 817
  • [38] Comparison of Dynamic Hip Screw and Proximal Femoral Nailing Techniques in Stable Intertrochanteric Fractures
    Shiraz, Salman
    Shujauddin, Mohammad
    Hasan, Khalid
    Elramadi, Ahmed
    Ahmed, Ghalib
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [39] Percutaneous Compression Plate versus Dynamic Hip Screw for Treatment of Intertrochanteric Hip Fractures: A Meta-Analyse of Five Randomized Controlled Trials
    Zhang, Lei
    Shen, Jie
    Yu, Shengpeng
    Huang, Qiang
    Xie, Zhao
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [40] Intramedullary nail versus extramedullary plate fixation for unstable intertrochanteric fractures: decision analysis
    Lee, Young-Kyun
    Chung, Chin Youb
    Park, Moon Seok
    Lee, Kyoung Min
    Koo, Kyung-Hoi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (07) : 961 - 968