Predictive power management strategies for stand-alone hydrogen systems: Lab-scale validation

被引:41
作者
Brka, Adel [1 ]
Kothapalli, Ganesh [1 ]
Al-Abdeli, Yasir M. [1 ]
机构
[1] Edith Cowan Univ, Sch Engn, Joondalup, WA 6027, Australia
关键词
Intelligent; Predictive; Power management strategy; Experiments; Real-time; Hydrogen; DATA-ACQUISITION SYSTEM; HYBRID ENERGY SYSTEM; SITE WATER PRODUCTION; OF-CHARGE ESTIMATION; RENEWABLE ENERGY; OPERATIONAL CHARACTERISTICS; PERFORMANCE ASSESSMENT; GENERATION SYSTEMS; SOLAR-RADIATION; OPTIMAL-DESIGN;
D O I
10.1016/j.ijhydene.2015.06.081
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Power Management Strategies (PMSs) to control stand-alone energy systems affect the reliability of meeting load demand as well as the cyclic operation of various subsystems. The hybridisation of sources through the integration of hydrogen fuel cells with energy storage means optimising the PMS should be "intelligently" done unless relying on rule-based PMSs which are simplistic to use but subject to lack of optimisation. This paper presents the methodology and validation of a lab-scale (desktop) energy system controlled by a predictive PMS. Validation of the intelligently based PMS can be done in the lab-scale before (costly) full deployment in the field, but experiments to support this have not been reported in relation to hydrogen systems. The experimentally tested hybrid energy system consists of an emulated renewable power source which can represent solar-PV and/or wind generators, battery bank and PEM fuel cell integrated with metal hydride storage. Experimental testing as well as the use of real-time predictions using Neural Networks is utilised. The effects of several control parameters which are either hardware dependant or affect the predictive algorithm are investigated with system performance, under the predictive PMS, benchmarked against a rule-based PMS. The results reveal that a predictive PMS is impacted by the prediction horizon used to forecast the availability of renewables or load, the decision time interval used for updating the PMS as well as time lags resulting from hardware sensors used to convey system status to the decision algorithm responsible for updating the PMS. The maximum thresholds of the above mentioned control parameters are 120, 15 and 3 s, respectively. Beyond these limits, the ability of the predictive PMS to effectively control the system degrades significantly. This study demonstrates the feasibility of using real-time predictions of renewable resources and load demand to optimise a PMS in a stand-alone energy system and experimentally validates this, which has not been previously reported. Copyright (C) 2015, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:9907 / 9916
页数:10
相关论文
共 59 条
  • [1] Economical assessment of a wind-hydrogen energy system using WindHyGen® software
    Aguado, Monica
    Ayerbe, Elixabete
    Azcarate, Cristina
    Blanco, Rosa
    Garde, Raquel
    Mallor, Fermin
    Rivas, David M.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (07) : 2845 - 2854
  • [2] VRLA battery state-of-charge estimation in telecommunication power systems
    Anbuky, AH
    Pascoe, PE
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (03) : 565 - 573
  • [3] Dimensionless analysis of the global techno-economic feasibility of solar-hydrogen systems for constant year-round power supply
    Andrews, John
    Shabani, Bahman
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (01) : 6 - 18
  • [4] Genetic-Algorithm-Based Optimization Approach for Energy Management
    Arabali, A.
    Ghofrani, M.
    Etezadi-Amoli, M.
    Fadali, M. S.
    Baghzouz, Y.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (01) : 162 - 170
  • [5] Ballard Power Systems, 2014, NEX POW MOD US MAN M
  • [6] Comparative performance analysis of a hybrid PV/FC/battery stand-alone system using different power management strategies and sizing approaches
    Behzadi, Mohammad Sadigh
    Niasati, Mohsen
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (01) : 538 - 548
  • [7] Data acquisition system for photovoltaic systems performance monitoring
    Benghanem, M
    Maafi, A
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (01) : 30 - 33
  • [8] Data acquisition system for photovoltaic water pumps
    Benghanem, M
    Arab, AH
    Mukadam, K
    [J]. RENEWABLE ENERGY, 1999, 17 (03) : 385 - 396
  • [9] Seasonal energy storage system based on hydrogen for self sufficient living
    Bielmann, M.
    Vogt, U. F.
    Zimmermann, M.
    Zuettel, A.
    [J]. JOURNAL OF POWER SOURCES, 2011, 196 (08) : 4054 - 4060
  • [10] Control analysis of renewable energy system with hydrogen storage for residential applications
    Bilodeau, A.
    Agbossou, K.
    [J]. JOURNAL OF POWER SOURCES, 2006, 162 (02) : 757 - 764