Highly affine and selective aptamers against cholera toxin as capture elements in magnetic bead-based sandwich ELAA

被引:33
作者
Frohnmeyer, Esther [1 ,2 ]
Frisch, Farina [1 ,2 ]
Falke, Sven [3 ]
Betzel, Christian [3 ]
Fischer, Markus [1 ,2 ]
机构
[1] Hamburg Sch Food Sci, Hamburg, Germany
[2] Univ Hamburg, Inst Food Chem, Grindelallee 117, D-20146 Hamburg, Germany
[3] Univ Hamburg, Inst Biochem & Mol Biol, Lab Struct Biol Infect & Inflammat, Martin Luther King Pl 6, D-20146 Hamburg, Germany
关键词
Aptamer; Cholera toxin; Just in time-selection; Affinity chromatography; Magnetic beads; ELAA; SENSITIVE DETECTION; VIBRIO-CHOLERAE; SSDNA APTAMERS; DNA APTAMERS; SERVER; CHAIN; ASSAY; SELEX; TIME;
D O I
10.1016/j.jbiotec.2018.01.012
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Aptamers are single-stranded DNA or RNA oligonucleotides, which have been emerging as recognition elements in disease diagnostics and food control, including the detection of bacterial toxins. In this study, we employed the semi-automated just in time-selection to identify aptamers that bind to cholera toxin (CT) with high affinity and specificity. CT is the main virulence factor of Vibrio cholerae and the causative agent of the eponymous disease. For the selected aptamers, dissociation constants in the low nanomolar range (23-56 nM) were determined by fluorescence-based affinity chromatography and cross-reactivity against related proteins was evaluated by direct enzyme-linked aptamer assay (ELAA). Aptamer CT916 has a dissociation constant of 48.5 +/- 0.5 nM and shows negligible binding to Shiga-like toxin 1B, protein A and BSA. This aptamer was chosen to develop a sandwich ELAA for the detection of CT from binding buffer and local tap water. Amine-C6- or biotin-modified CT916 was coupled to magnetic beads to serve as the capture element. Using an anti-CT polyclonal antibody as the reporter, detection limits of 2.1 ng/ml in buffer and 2.4 ng/ml in tap water, with a wide log-linear dynamic range from 1 ng/ml to 1000 ng/ml and 500 ng/ml, respectively, were achieved.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 40 条
[1]   Updated Global Burden of Cholera in Endemic Countries [J].
Ali, Mohammad ;
Nelson, Allyson R. ;
Lopez, Anna Lena ;
Sack, David A. .
PLOS NEGLECTED TROPICAL DISEASES, 2015, 9 (06)
[2]   COMPARISON OF A LATEX AGGLUTINATION ASSAY AND AN ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR DETECTING CHOLERA-TOXIN [J].
ALMEIDA, RJ ;
HICKMANBRENNER, FW ;
SOWERS, EG ;
PUHR, ND ;
FARMER, JJ ;
WACHSMUTH, IK .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (01) :128-130
[3]   A nanocoaxial-based electrochemical sensor for the detection of cholera toxin [J].
Archibald, Michelle M. ;
Rizal, Binod ;
Connolly, Timothy ;
Burns, Michael J. ;
Naughton, Michael J. ;
Chiles, Thomas C. .
BIOSENSORS & BIOELECTRONICS, 2015, 74 :406-410
[4]   MEME SUITE: tools for motif discovery and searching [J].
Bailey, Timothy L. ;
Boden, Mikael ;
Buske, Fabian A. ;
Frith, Martin ;
Grant, Charles E. ;
Clementi, Luca ;
Ren, Jingyuan ;
Li, Wilfred W. ;
Noble, William S. .
NUCLEIC ACIDS RESEARCH, 2009, 37 :W202-W208
[5]   Cholera Toxin B: One Subunit with Many Pharmaceutical Applications [J].
Baldauf, Keegan J. ;
Royal, Joshua M. ;
Hamorsky, Krystal Teasley ;
Matoba, Nobuyuki .
TOXINS, 2015, 7 (03) :974-996
[6]   Use of magnetic beads in selection and detection of biotoxin aptamers by electrochemiluminescence and enzymatic methods [J].
Bruno, JG ;
Kiel, JL .
BIOTECHNIQUES, 2002, 32 (01) :178-+
[7]   Combining use of a panel of ssDNA aptamers in the detection of Staphylococcus aureus [J].
Cao, Xiaoxiao ;
Li, Shaohua ;
Chen, Liucun ;
Ding, Hongmei ;
Xu, Hua ;
Huang, Yanping ;
Li, Jie ;
Liu, Nongle ;
Cao, Weihong ;
Zhu, Yanjun ;
Shen, Beifen ;
Shao, Ningsheng .
NUCLEIC ACIDS RESEARCH, 2009, 37 (14) :4621-4628
[8]   Nano Aptasensor for Protective Antigen Toxin of Anthrax [J].
Cella, Lakshmi N. ;
Sanchez, Pablo ;
Zhong, Wenwan ;
Myung, Nosang V. ;
Chen, Wilfred ;
Mulchandani, Ashok .
ANALYTICAL CHEMISTRY, 2010, 82 (05) :2042-2047
[9]   Selection of RNA Aptamers Against Botulinum Neurotoxin Type A Light Chain Through a Non-Radioactive Approach [J].
Chang, Tzuu-Wang ;
Janardhanan, Pavithra ;
Mello, Charlene M. ;
Singh, Bal Ram ;
Cai, Shuowei .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2016, 180 (01) :10-25
[10]   Replacing antibodies with aptamers in lateral flow immunoassay [J].
Chen, Ailiang ;
Yang, Shuming .
BIOSENSORS & BIOELECTRONICS, 2015, 71 :230-242