MECHANICAL AND IN VITRO CORROSION BEHAVIOUR OF Fe-CONTAINING TiNb(Zr-Fe)Ta ALLOYS

被引:0
作者
Gonzalez, S. [1 ]
Pellicer, E. [1 ]
Rossinyol, E. [2 ]
Surinach, S. [1 ]
Baro, M. D. [1 ]
Sort, J. [1 ,3 ]
机构
[1] Univ Autonoma Barcelona, Dept Fis, Bellaterra 08193, Spain
[2] Univ Autonoma Barcelona, Serv Microscopia, Bellaterra 08193, Spain
[3] Univ Autonoma Barcelona, Inst Catalana Recerca & Estudis Avancats, Bellaterra 08193, Spain
关键词
Metals and alloys; Rapid solidification; Corrosion; NB-ZR-TA; STRENGTHENING MECHANISMS; TI-13NB-13ZR ALLOY; TI; MODULUS;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The mechanical behaviour and corrosion resistance, in simulated body fluid, of novel Ti-45Nb-(7-x)Zr-12.5Ta-xFe (x = 0, 3 and 7 wt. %) alloys have been investigated. Partial substitution of Zr by Fe, a cheaper. beta-stabilizing element, allows decreasing the Young's modulus and slightly improving the wear resistance. Moreover, moderate additions of Fe shift the corrosion potential towards more positive values, thus making these materials suitable for biomedical applications.
引用
收藏
页码:641 / 647
页数:7
相关论文
共 15 条
  • [1] Phase stability change with Zr content in β-type Ti-Nb alloys
    Abdel-Hady, Mohamed
    Fuwa, Hiroki
    Hinoshita, Keita
    Kimura, Haruka
    Shinzato, Yoshifumi
    Morinaga, Masahiko
    [J]. SCRIPTA MATERIALIA, 2007, 57 (11) : 1000 - 1003
  • [2] Strengthening mechanisms in Ti-Nb-Zr-Ta and Ti-Mo-Zr-Fe orthopaedic alloys
    Banerjee, R
    Nag, S
    Stechschulte, J
    Fraser, HL
    [J]. BIOMATERIALS, 2004, 25 (17) : 3413 - 3419
  • [3] DAVIDSON JA, 1994, BIO-MED MATER ENG, V4, P231
  • [4] Enhanced mechanical properties due to structural changes induced by devitrification in Fe-Co-B-Si-Nb bulk metallic glass
    Fornell, J.
    Gonzalez, S.
    Rossinyol, E.
    Surinach, S.
    Baro, M. D.
    Louzguine-Luzgin, D. V.
    Perepezko, J. H.
    Sort, J.
    Inoue, A.
    [J]. ACTA MATERIALIA, 2010, 58 (19) : 6256 - 6266
  • [5] Influence of microstructure and alloying elements on corrosion behavior of Ti-13Nb-13Zr alloy
    Geetha, M
    Mudali, UK
    Gogia, AK
    Asokamani, R
    Raj, B
    [J]. CORROSION SCIENCE, 2004, 46 (04) : 877 - 892
  • [6] Ti based biomaterials, the ultimate choice for orthopaedic implants - A review
    Geetha, M.
    Singh, A. K.
    Asokamani, R.
    Gogia, A. K.
    [J]. PROGRESS IN MATERIALS SCIENCE, 2009, 54 (03) : 397 - 425
  • [7] Improved mechanical performance and delayed corrosion phenomena in biodegradable Mg-Zn-Ca alloys through Pd-alloying
    Gonzalez, S.
    Pellicer, E.
    Fornell, J.
    Blanquer, A.
    Barrios, L.
    Ibanez, E.
    Solsona, P.
    Surinach, S.
    Baro, M. D.
    Nogues, C.
    Sort, J.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 6 : 53 - 62
  • [8] Electrochemical and XPS studies of corrosion behavior of Ti-23Nb-0.7Ta-2Zr-O alloy in Ringer's solution
    Guo, W. Y.
    Sun, J.
    Wu, J. S.
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2009, 113 (2-3) : 816 - 820
  • [9] Halling J., 1982, Tribologia, V1, P15
  • [10] Martensitic transformation, shape memory effect and superelasticity of Ti-Nb binary alloys
    Kim, H. Y.
    Ikehara, Y.
    Kim, J. I.
    Hosoda, H.
    Miyazaki, S.
    [J]. ACTA MATERIALIA, 2006, 54 (09) : 2419 - 2429