HYDRAULIC ASSESSMENT OF FLOW IN STEPPED AND LABYRINTH SPILLWAYS TO DETERMINE ENERGY LOSS USING A PHYSICAL MODEL

被引:0
作者
Banishoaib, Seyed Ali [1 ,2 ]
Bordbar, Amin [2 ]
Kamanbedast, Amirabbas [2 ]
Masjedi, Alireza [2 ]
Heidarnejad, Mohammad [2 ]
机构
[1] Islamic Azad Univ, Khuzestan Sci & Res Branch, Dept Water Sci & Engn, Ahvaz, Iran
[2] Islamic Azad Univ, Ahvaz Branch, Dept Water Sci & Engn, Ahvaz, Iran
来源
FRESENIUS ENVIRONMENTAL BULLETIN | 2018年 / 27卷 / 02期
关键词
Labyrinth Spillway; Stepped Spillway; Energy Dissipation; Physical Model; SKIMMING FLOW; COEFFICIENT; WEIRS;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A 'spillway' is a structure used to provide controlled release of flood water from upstream into downstream area of a dam. As an important component of every dam, a spillway should be constructed strongly, reliably, and efficiently to be used at any moment. Labyrinth and stepped spillways are presented as appropriate modifications to those spillways hardly capable of managing maximum potential discharge. Owing to their nonlinear crests for a given width, labyrinth and stepped spillways have a larger discharge rate than linear-crest spillways at an identical height. Compared to other energy dissipaters, the combination of stepped and labyrinth spillways is known as a very strong energy dissipater. In the following part, the combination of these two structures and their dimensional change for increasing water-energy dissipation are addressed. To conduct this laboratory study, an experimental flume with a 90-degree bend in the Islamic Azad University of Ahwaz was used. In total, 90 experiments were conducted on three different labyrinth-shape stepped spillway models with two different lengths, three different widths, and five different discharges. Analysis of results showed a greater energy loss reduction in triangular than rectangular than trapezoidal labyrinth -shape stepped spillways. In addition, energy loss is greater in labyrinth spillways with two cycles than with one cycle. Energy loss increases by increasing the Froude number from 0.05 to 0.1; whereas energy loss decreases with increasing the Froude number from 0.1 to 1.0, which is due to the submergence of steps, a decrease in roughness of steps, and an increase in the intensity of aeration.
引用
收藏
页码:910 / 920
页数:11
相关论文
共 58 条
[41]  
Maynord S.T, 1985, HL851
[42]  
Mousavi-ahromi S. H., 2009, 8 INT C CIV ENG SHIR
[43]  
Mousavi-Jahromi S. H., 2009, 8 INT C CIV ENG SHIR
[44]  
Mousavi-Jahroumi H., 2009, 1 NAT ENG MAN C ENG
[45]   Three-dimensional numerical flow modelling for estimation of spillway capacity [J].
Olsen, NRB ;
Kjellesvig, HM .
JOURNAL OF HYDRAULIC RESEARCH, 1998, 36 (05) :775-784
[46]  
Rajaratnam N, 1990, J HYDRAULIC ENG, V116
[47]   Model study of a roller compacted concrete stepped spillway [J].
Rice, CE ;
Kadavy, KC .
JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1996, 122 (06) :292-297
[48]  
Rodi W, 1980, TURBULENCE MODELS TH, P27
[49]  
Rostami H, 2016, FRESEN ENVIRON BULL, V25, P5138
[50]  
Rouzegar J, 2017, FRESEN ENVIRON BULL, V26, P2389