The CMS all-silicon Tracker, comprising 16588 modules covering an area of more than 200m(2), needs to be precisely calibrated and aligned in order to correctly interpret and reconstruct the events recorded from the detector, ensuring that the performance fully meets the physics research program of the CMS experiment. The performance has been carefully studied since the start of data taking: the noise of the detector, the data integrity, the S/N ratio, the hit resolution and efficiency have been all investigated with time. In 2010 the Tracker has been successfully aligned using tracks from cosmic rays and pp-collisions, following the time dependent movements of its innermost pixel layers. Ultimate local precision is now achieved by the determination of sensor curvatures, challenging the algorithms to determine about 200000 parameters. Remaining alignment uncertainties are dominated by systematic effects that are controlled by adding further information, such as constraints from resonance decays.
引用
收藏
页码:1084 / 1088
页数:5
相关论文
共 9 条
  • [1] [Anonymous], CERNLHCC9806 CMS COL
  • [2] BRUNING O, 2004, CERN2004003, V1
  • [3] Alignment of the CMS silicon tracker during commissioning with cosmic rays
    Chatrchyan, S.
    Khachatryan, V.
    Sirunyan, A. M.
    Adam, W.
    Arnold, B.
    Bergauer, H.
    Bergauer, T.
    Dragicevic, M.
    Eichberger, M.
    Eroe, J.
    Friedl, M.
    Fruehwirth, R.
    Ghete, V. M.
    Hammer, J.
    Haensel, S.
    Hoch, M.
    Hoermann, N.
    Hrubec, J.
    Jeitler, M.
    Kasieczka, G.
    Kastner, K.
    Krammer, M.
    Liko, D.
    de Abril, I. Magrans
    Mikulec, I.
    Mittermayr, F.
    Neuherz, B.
    Oberegger, M.
    Padrta, M.
    Pernicka, M.
    Rohringer, H.
    Schmid, S.
    Schoefbeck, R.
    Schreiner, T.
    Stark, R.
    Steininger, H.
    Strauss, J.
    Taurok, A.
    Teischinger, F.
    Themel, T.
    Uhl, D.
    Wagner, P.
    Waltenberger, W.
    Walzel, G.
    Widl, E.
    Wulz, C. -E.
    Chekhovsky, V.
    Dvornikov, O.
    Emeliantchik, I.
    Litomin, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2010, 5
  • [4] The CMS experiment at the CERN LHC
    Chatrchyan, S.
    Hmayakyan, G.
    Khachatryan, V.
    Sirunyan, A. M.
    Adam, W.
    Bauer, T.
    Bergauer, T.
    Bergauer, H.
    Dragicevic, M.
    Eroe, J.
    Friedl, M.
    Fruehwirth, R.
    Ghete, V. M.
    Glaser, P.
    Hartl, C.
    Hoermann, N.
    Hrubec, J.
    Haensel, S.
    Jeitler, M.
    Kastner, K.
    Krammer, M.
    de Abril, I. Magrans
    Markytan, M.
    Mikulec, I.
    Neuherz, B.
    Noebauer, T.
    Oberegger, M.
    Padrta, M.
    Pernicka, M.
    Porth, P.
    Rohringer, H.
    Schmid, S.
    Schreiner, T.
    Stark, R.
    Steininger, H.
    Strauss, J.
    Taurok, A.
    Uhl, D.
    Waltenberger, W.
    Walzel, G.
    Widl, E.
    Wulz, C. -E.
    Petrov, V.
    Prosolovich, V.
    Chekhovsky, V.
    Dvornikov, O.
    Emeliantchik, I.
    Litomin, A.
    Makarenko, V.
    Marfin, I.
    [J]. JOURNAL OF INSTRUMENTATION, 2008, 3
  • [5] CMS collaboration, 2000, CERNLHCC2000016 CMS
  • [6] The Data Quality Monitoring of the CMS Experiment : the Tracker Case
    Dutta, S.
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2009, 197 : 271 - 274
  • [7] Hartmann F., 2011, 20 ANN INT WORKSH VE
  • [8] PAOLETTI S, 2004, P 10 WORKSH EL LHC F
  • [9] The CMS Tracker Detector Control System
    Shah, S. Yousaf
    Tsirou, Andromachi
    Verdini, Piero Giorgio
    Hartmann, Frank
    Masetti, Lorenzo
    Dirkes, Guido H.
    Stringer, Robert
    Fahrer, Manuel
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2) : 281 - 283