Optimizing Electrode-Attached Redox-Peptide Systems for Kinetic Characterization of Protease Action on Immobilized Substrates. Observation of Dissimilar Behavior of Trypsin and Thrombin Enzymes

被引:23
作者
Anne, Agnes [1 ]
Chovin, Arnaud [1 ]
Demaille, Christophe [1 ]
机构
[1] Univ Paris Diderot, CNRS, UMR 7591, Lab Electrochim Mol, F-75205 Paris 13, France
关键词
ELECTROCHEMICAL APPROACH; ENZYMATIC-REACTIONS; MONOLAYERS; SURFACES; AU; VOLTAMMETRY; ADSORPTION; DYNAMICS; BINDING; ASSAY;
D O I
10.1021/la301316r
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, we experimentally address the issue of optimizing gold electrode attached ferrocene (Fc)-peptide systems for kinetic measurements of protease action. Considering human alpha-thrombin and bovine trypsin as proteases of interest, we show that the recurring problem of incomplete cleavage of the peptide layer by these enzymes can be solved by using ultraflat template-stripped gold, instead of polished polycrystalline gold, as the Fc-peptide bearing electrode material. We describe how these fragile surfaces can be mounted in a rotating disk configuration so that enzyme mass transfer no longer limits the overall measured cleavage kinetics. Finally, we demonstrate that, once the system has been optimized, in situ real-time cyclic voltammetry monitoring of the protease action can yield high-quality kinetic data, showing no sign of interfering effects. The cleavage progress curves then closely match the Langmuirian variation expected for a kinetically controlled surface process. Global fit of the progress curves yield accurate values of the peptide cleavage rate for both trypsin and thrombin. It is shown that, whereas trypsin action on the surface-attached peptide closely follows Michaelis-Menten kinetics, thrombin displays a specific and unexpected behavior characterized by a nearly enzyme-concentration-independent cleavage rate in the subnanomolar enzyme concentration range. The reason for this behavior has still to be clarified, but its occurrence may limit the sensitivity of thrombin sensors based on Fc-peptide layers.
引用
收藏
页码:8804 / 8813
页数:10
相关论文
共 47 条
[31]   Ferrocene-peptido conjugates: From synthesis to sensory applications [J].
Martic, Sanela ;
Labib, Mahmoud ;
Shipman, Patrick O. ;
Kraatz, Heinz-Bernhard .
DALTON TRANSACTIONS, 2011, 40 (28) :7264-7290
[32]   Enzymatically modified peptide surfaces: towards general electrochemical sensor platform for protein kinase catalyzed phosphorylations [J].
Martic, Sanela ;
Labib, Mahmoud ;
Kraatz, Heinz-Bernhard .
ANALYST, 2011, 136 (01) :107-112
[33]   Determination of kinetic parameters for interfacial enzymatic reactions on self-assembled monolayers [J].
Nayak, Satish ;
Yeo, Woon-Seok ;
Mrksich, Milan .
LANGMUIR, 2007, 23 (10) :5578-5583
[34]   Kinetic studies of AMP-dependent phosphorolysis of amylopectin catalyzed by phosphorylase b on a 27 MHz quartz-crystal microbalance [J].
Nishino, H ;
Murakawa, A ;
Mori, T ;
Okahata, Y .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (45) :14752-14757
[35]   Direct monitoring of enzymatic glucan hydrolysis on a 27-MHz quartz-crystal microbalance [J].
Nishino, H ;
Nihira, T ;
Mori, T ;
Okahata, Y .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (08) :2264-2265
[36]   Electrochemical assay of plasmin activity and its kinetic analysis [J].
Ohtsuka, Keiichi ;
Maekawa, Iwao ;
Waki, Michinori ;
Takenaka, Shigeori .
ANALYTICAL BIOCHEMISTRY, 2009, 385 (02) :293-299
[37]   Short peptides as biosensor transducers [J].
Pavan, Silvia ;
Berti, Federico .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (10) :3055-3070
[38]   Analysis of mass transport-limited binding kinetics in evanescent wave biosensors [J].
Schuck, P ;
Minton, AP .
ANALYTICAL BIOCHEMISTRY, 1996, 240 (02) :262-272
[39]   ROTATING-RING-DISK ENZYME ELECTRODE FOR SURFACE CATALYSIS STUDIES [J].
SHU, FR ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1976, 48 (12) :1679-1686
[40]   SIGNIFICANCE OF INTERMEDIARY PLATEAU REGIONS IN ENZYME SATURATION CURVES [J].
TEIPEL, J ;
KOSHLAND, DE .
BIOCHEMISTRY, 1969, 8 (11) :4656-&