Radiation protection in 90Y-labelled DOTA-D-Phe1-Tyr3-octreotide preparations

被引:16
作者
Grassi, Elisa [1 ]
Sghedoni, Roberto [1 ]
Asti, Mattia [2 ]
Fioroni, Federica [1 ]
Salvo, Diana [2 ]
Borasi, Giovanni [1 ]
机构
[1] Santa Maria Nova Hosp, Dept Med Phys, Reggio Emilia, Italy
[2] Santa Maria Nova Hosp, Dept Nucl Med, Reggio Emilia, Italy
关键词
beta-radiation; finger dose; radiation exposure; skin exposure; Y-90; NEUROENDOCRINE TUMORS; DOSIMETRY; PERSONNEL; EXPOSURE; THERAPY;
D O I
10.1097/MNM.0b013e328318effb
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Beta-emitting radionuclides are being increasingly used in targeted radionuclide therapy in nuclear medicine. In particular, the pure high-energy P-emitter Y-90 (E-max=2.27 MeV) has a physical half-life compatible with the pharmacokinetics of peptides. The use of this isotope implies an increase in the radiation dose received by the nuclear medicine staff. The aim of this study is thus the evaluation of the personal beta-dosimetry data related to therapeutic Y-90-labelled DOTA-D-Phe1-Tyr3-octreotide preparation and administration in a nuclear medicine department. Methods Personal dose measurements were carried out with a series of thin active layer ultrasensitive MCP-Ns (LiF: Mg, Cu, P) dosimeters fixed at the operator's fingertips and by means of some direct reading dosimeters; other individual protection devices, such as shielded aprons and anti-X gloves, were also used. Results The 95th percentile of the chemist's skin equivalent dose distribution was 1.759 mSv/GBq by using 0.10-mm anti-X gloves and 0.265 mSv/GBq by using 0.20-mm anti-X gloves. The 95th percentile of the physician's skin equivalent dose distribution was 1.198 mSv/GBq by using 0.10-mm anti-X gloves. The use of an anti-X apron is during administration permits saving absorbed doses by a factor over 97% for both Hp(10) and Hp(0.07). Conclusion Because of the physical properties of beta-emitters, an increased number of therapeutic sessions is to be expected. The dose values measured till now, resulting from a high radioprotection level modus operandi, have always respected the threshold limits reported by the European Directive EURATOM 96/29 05/13/1996 for exposed workers, even in addition to other clinical practices in the department. Nucl Med Commun 30:176-182 (C) 2009 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:176 / 182
页数:7
相关论文
共 23 条
[1]  
[Anonymous], 2008, ANN ICRP
[2]   ULTRA-THIN LIF-MG,CU,P DETECTORS FOR BETA-DOSIMETRY [J].
BILSKI, P ;
OLKO, P ;
BURGKHARDT, B ;
PIESCH, E .
RADIATION MEASUREMENTS, 1995, 24 (04) :439-443
[3]   Characterisation of MCP-7s material for use as a beta extremity dosemeter [J].
Boschung, M ;
Homsy, A ;
Joneja, OP ;
Chawla, R .
RADIATION PROTECTION DOSIMETRY, 2000, 92 (04) :313-318
[4]  
Chérel M, 2006, Q J NUCL MED MOL IM, V50, P322
[5]   Personal dose monitoring in hospitals: Global assessment, critical applications and future needs [J].
Covens, P. ;
Berus, D. ;
Buls, N. ;
Clerinx, P. ;
Vanhavere, F. .
RADIATION PROTECTION DOSIMETRY, 2007, 124 (03) :250-259
[6]   Radiation protection in radionuclide therapies with 90Y-conjugates:: risks and safety [J].
Cremonesi, Marta ;
Ferrari, Mahila ;
Paganelli, Giovanni ;
Rossi, Annalisa ;
Chinol, Marco ;
Bartolomei, Mirco ;
Prisco, Gennaro ;
Tosi, Giampiero .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (11) :1321-1327
[7]  
Cremonesi M, 2006, J NUCL MED, V47, P1467
[8]   Initial evaluation of 227Th-p-benzyl-DOTA-rituximab for low-dose rate α-particle radioimmunotherapy [J].
Dahle, J ;
Borrebæk, J ;
Melhus, KB ;
Bruland, OS ;
Salberg, G ;
Olsen, DR ;
Larsen, RH .
NUCLEAR MEDICINE AND BIOLOGY, 2006, 33 (02) :271-279
[9]   Yttrium-90 and indium-111 labelling, receptor binding and biodistribution of [DOTA(0),D-Phe(1),Tyr(3)]octreotide, a promising somatostatin analogue for radionuclide therapy [J].
deJong, M ;
Bakker, WH ;
Krenning, EP ;
Breeman, WAP ;
vanderPluijm, ME ;
Bernard, BF ;
Visser, TJ ;
Jermann, E ;
Behe, M ;
Powell, P ;
Macke, HR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (04) :368-371
[10]  
Delacroix D, 2002, RADIAT PROT DOSIM, V98, P9, DOI 10.1093/oxfordjournals.rpd.a006705