Biomechanical measurements of cortical screw purchase in five types of human and artificial humeri

被引:19
作者
Aziz, Mina S. R. [1 ,2 ]
Nicayenzi, Bruce [1 ]
Crookshank, Meghan C. [1 ]
Bougherara, Habiba [3 ]
Schemitsch, Emil H. [1 ,4 ]
Zdero, Radovan [1 ,3 ]
机构
[1] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Univ Toronto, Inst Med Sci, Toronto, ON M5S 1A8, Canada
[3] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[4] Univ Toronto, Fac Med, Dept Surg, Toronto, ON M5S 1A8, Canada
关键词
Biomechanics; Cortical screw; Purchase; Pullout; Human; Artificial; Humerus; HOLDING POWER; STRIPPING TORQUE; PULLOUT STRENGTH; INSERTION TORQUE; BONE; FIXATION;
D O I
10.1016/j.jmbbm.2013.11.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Humerus shaft fracture fixation is largely dependent on cortical screw purchase in host bone. Only 2 prior studies assessed cortical screw purchase in human humeral shafts, but were of very limited scope and did not fully assess humerus material properties. Also, no studies evaluated the human dried or artificial humeri both commercially available from Sawbones. Vashon, WA, USA. Therefore, present authors measured cortical screw purchase in human fresh-frozen (FF) (n=19), human embalmed (EM) (n=18), human dried (DR) (n=14), artificial "normal" (AN) (n=13), and artificial "osteoporotic" (AO) (n=13) humeri. Each humerus had 2 bicortical screws of 3.5-mm diameter inserted 20 mm apart through the shaft's anterior and posterior cortices. Absolute force, displacement, and energy for screw-bone interface failure were measured by screw pullout tests, afterwhich data were normalized by total surface area engaged at the screw-bone interface. For absolute force, AN humeri reached a higher load than EM (p=0.001) and AO (p<0.001) humeri, whilst AN humeri achieved lower normalized force than DR humeri (p=0.018). For absolute displacement, AO humeri achieved a lower level than FF humeri (p=0.013), whilst for normalized displacement AN humeri had lower levels than all other groups (p <= 0.005) and AO humeri had lower values than EM humeri (p=0.029). For absolute and normalized energy, there were no statistical differences (p >= 0.066). Human bone mineral density (BMD) ranged from 0.7 to 1.8 g/cm(2) and was linearly correlated to screw pullout parameters in 14 of 18 cases (R=0.61 to 0.96), whilst humerus age was not. Consequently, it is recommended that human fresh-frozen, human embalmed, and human dried humeri can be used interchangeably for cortical screw purchase, since they were statistically equivalent for all comparisons. However, artificial humeri were involved in all statistical differences observed and, thus, may not replicate cortical screw purchase in human humeri. To date, this is the most comprehensive study on cortical screw purchase in human and artificial humeral shafts. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:159 / 167
页数:9
相关论文
共 34 条
[1]  
An YH, 1998, ANIMAL MODELS IN ORTHOPAEDIC RESEARCH, P139
[2]  
[Anonymous], F54307 ASTM INT
[3]  
Ansell R H, 1968, J Biomech, V1, P279, DOI 10.1016/0021-9290(68)90023-7
[4]   Factors affecting the pullout strength of cancellous bone screws [J].
Chapman, JR ;
Harrington, RM ;
Lee, KM ;
Anderson, PA ;
Tencer, AF ;
Kowalski, D .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :391-398
[5]  
Cordey J., 1980, CURRENT CONCEPTS INT, P235
[6]   Biomechanical measurements of axial crush injury to the distal condyles of human and synthetic femurs [J].
Crookshank, Meghan ;
Coquim, Jason ;
Olsen, Michael ;
Schemitsch, Emil H. ;
Bougherara, Habiba ;
Zdero, Rad .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H4) :320-329
[7]   Stripping torque as a predictor of successful internal fracture fixation [J].
Edwards, TR ;
Tevelen, G ;
English, H ;
Crawford, R .
ANZ JOURNAL OF SURGERY, 2005, 75 (12) :1096-1099
[8]   Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems - A biomechanical comparison of locked plating and conventional cable plates [J].
Fulkerson, E ;
Koval, K ;
Preston, CF ;
Iesaka, K ;
Kummer, FJ ;
Egol, KA .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (02) :89-93
[9]   Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies [J].
Inceoglu, Serkan ;
Montgomery, William H., Jr. ;
St Clair, Selvon ;
McLain, Robert F. .
JOURNAL OF NEUROSURGERY-SPINE, 2011, 14 (05) :670-676
[10]  
Infante A. F., 2008, TRAUMA CORE KNOWLEDG, P79