Commissioning and Evaluation of a Fiber-Optic Sensor System for Bridge Monitoring

被引:28
作者
Scott, Richard H. [1 ]
Banerji, Pradipta [2 ]
Chikermane, Sanjay [2 ]
Srinivasan, Sudarshan [3 ]
Basheer, P. A. Muhammed [3 ]
Surre, Frederic [4 ]
Sun, Tong [4 ]
Grattan, Kenneth T. V. [4 ]
机构
[1] Univ Durham, Durham DH1 3LE, England
[2] Indian Inst Technol, Bombay 400076, Maharashtra, India
[3] Queens Univ Belfast, Belfast BT7 1NN, Antrim, North Ireland
[4] City Univ London, London EC1V 0HB, England
基金
英国工程与自然科学研究理事会;
关键词
Fiber-optic strain sensors; load tests; railway bridges; structural health monitoring;
D O I
10.1109/JSEN.2013.2256599
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the design, commissioning, and evaluation of a fiber-optic strain sensor system for the structural health monitoring of a prestressed concrete posttensioned box girder railway bridge in Mumbai, India, which shows a number of well-documented structural problems. Preliminary laboratory trials to design the most appropriate sensor system that could be readily transported and used on site are described, followed by a description of load tests on the actual bridge undertaken in collaboration with Indian Railways and using locomotives of known weight. Results from the load tests using the optical system are compared with similar results obtained using electrical resistance strain gages. Conclusions are summarized concerning the integrity of the structure and for the future use of the sensor system for monitoring bridges of this type. Crack width measurements obtained during the load tests are also described.
引用
收藏
页码:2555 / 2562
页数:8
相关论文
共 16 条
[1]   Fiber optic health monitoring of civil structures using long gage and acoustic sensors [J].
Ansari, F .
SMART MATERIALS & STRUCTURES, 2005, 14 (03) :S1-S7
[2]   High speed measurements using fiber-optic Bragg gratings [J].
Benterou, Jerry ;
May, Chadd ;
Udd, Eric ;
Mihailov, Stephen J. ;
Lu, Ping .
FIBER OPTIC SENSORS AND APPLICATIONS VIII, 2011, 8028
[3]   Fiber Bragg grating sensors for structural health monitoring of Tsing Ma bridge: Background and experimental observation [J].
Chan, THT ;
Yu, L ;
Tam, HY ;
Ni, YQ ;
Chung, WH ;
Cheng, LK .
ENGINEERING STRUCTURES, 2006, 28 (05) :648-659
[4]  
Dai J., 2007, P SPIE, V6830
[5]   A field deployable, multiplexed Bragg grating sensor system used in an extensive highway bridge monitoring evaluation tests [J].
Gebremichael, YM ;
Li, W ;
Meggitt, BT ;
Boyle, WJO ;
Grattan, KTV ;
McKinley, B ;
Boswell, LF ;
Aarnes, KA ;
Aasen, SE ;
Tynes, B ;
Fonjallaz, Y ;
Triantafillou, T .
IEEE SENSORS JOURNAL, 2005, 5 (03) :510-519
[6]  
Glisic B., 2002, P STRUCT HLTH MON WO, P285
[7]  
Grattan S.K., 2009, SENSOR ACTUAT A-PHYS, V1, P1
[8]   Monitoring of an all-composite bridge using Bragg grating sensors [J].
Kister, G. ;
Badcock, R. A. ;
Gebremichael, Y. M. ;
Boyle, W. J. O. ;
Grattan, K. T. V. ;
Fernando, G. F. ;
Canning, L. .
CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (07) :1599-1604
[9]  
Leung C. K. Y., 2005, P 11 C FRACT MAR, P1
[10]   Development and sensing properties study of FRP-FBG smart stay cable for bridge health monitoring applications [J].
Li, Dongsheng ;
Zhou, Zhi ;
Ou, Jinping .
MEASUREMENT, 2011, 44 (04) :722-729