COMPARATIVE PERFORMANCE OF TWO PROTOYPES OF A PASSIVE SOLAR HEAT PIPE SYSTEM

被引:0
|
作者
Robinson, Brian S. [1 ]
Sharp, M. Keith [1 ]
机构
[1] Univ Louisville, Louisville, KY 40292 USA
关键词
WALL;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal performance of an improved passive solar heat pipe system was directly compared to that of a previous prototype. Simulated and experimental results for the first prototype established baseline performance. Subsequently, potential improvements were simulated, and a second prototype was built and tested along side the first. The system uses heat pipes for high rates of heat transfer into the building, and limited losses in the reverse direction. The evaporator section of each heat pipe is attached to a glass-covered absorber on the outside of a south wall, and the slightly elevated condenser section is either immersed in water in a thermal storage tank or exposed to air in the room. Two-phase flow occurs in the heat pipe only when the evaporator is warmer than the condenser, creating a thermal diode effect. Computer simulations showed that system performance could be improved by using thicker insulation between the absorber and the storage tanks, and by switching from a copper to a rubber adiabatic section, which both reduced heat losses to ambient from the storage tanks. Early morning heating was improved by exposing one of five condensers directly to room air, which also improved overall system efficiency. A copper solar absorber soldered to the copper evaporator section improved heat conduction compared to the previous aluminum absorber bonded to the copper evaporator. Together these modifications improved simulated annual solar fraction by 20.8%. The new prototype incorporating these changes was tested along side the previous prototype in a tworoom passive solar test facility during January through February of 2013. Temperatures were monitored with thermocouples at multiple locations throughout the systems, in each room and outdoors. Insolation was measured by four pyranometers attached to the building. Results showed that the design modifications implemented for the new model increased thermal gains to storage and to the room, and decreased thermal losses to ambient. The load-to-collector ratio for the experiments was 2.7 times lower than for the simulations, which decreased the potential for experimental improvements compared to the simulated improvements. However, average daily peak efficiency for the new system was 85.0%, compared to 80.7% for the previous system. Furthermore, the average storage temperature over the entire testing period for the new model was 13.4% higher than that of the previous model, while the average room temperature over the same period was 24.6% greater for the new system.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Performance Analysis of Water Heat Pipe for Application of the Passive Cooling System in Nuclear Power Plants
    Park, Ye Yeong
    Bang, In Cheol
    NUCLEAR TECHNOLOGY, 2024,
  • [22] Investigation on the Performance of a Wickless-Heat Pipe Using Graphene Nanofluid for Passive Cooling System
    Kusuma, M. H.
    Putra, N.
    Rosidi, A.
    Ismarwanti, S.
    Antariksawan, A. R.
    Ardiyati, T.
    Juarsa, M.
    Mahlia, T. M., I
    ATOM INDONESIA, 2019, 45 (03) : 173 - 182
  • [23] Effect of energy storage materials on performance of solar heat pump system with inserted heat pipe in winter
    Wu W.
    Xia M.
    Yin Z.
    Gao X.
    Huang J.
    Qin Z.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2020, 36 (05): : 226 - 232
  • [24] PERFORMANCE OF A WICKLESS HEAT-PIPE SOLAR COLLECTOR
    ELNASR, MA
    ELHAGGAR, SM
    ENERGY SOURCES, 1993, 15 (03): : 513 - 522
  • [25] Passive Solar System to Store Heat for Cooking
    Nydal, Ole Jorgen
    Thaule, Sigurd
    Kolderup, Marie
    Gustavson, Kaja
    Bjerre, Per
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 1617 - 1624
  • [26] CYCLIC PERFORMANCE OF A SODIUM HEAT PIPE, SOLAR REFORMER
    PARIPATYADAR, SA
    RICHARDSON, JT
    SOLAR ENERGY, 1988, 41 (05) : 475 - 485
  • [27] Experimental Investigation of the Effect of Heat Pipe Tilting on a Concentrated Photovoltaic/Heat Pipe Passive Cooling System
    Lashin, Abdelrahman
    Sabry, Mohamed
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (04):
  • [28] Comparative analysis of thermal performance in heat pipe heat exchangers employing two distinct convective heat transfer media
    Ramasamy Sethuraman
    Thambidurai Muthuvelan
    Sivasubramanian Mahadevan
    Journal of Thermal Analysis and Calorimetry, 2024, 149 : 4069 - 4085
  • [29] Comparative analysis of thermal performance in heat pipe heat exchangers employing two distinct convective heat transfer media
    Sethuraman, Ramasamy
    Muthuvelan, Thambidurai
    Mahadevan, Sivasubramanian
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (09) : 4069 - 4085
  • [30] Passive Heat Recovery System using Combination of Heat Pipe and Thermoelectric Generator
    Remeli, M. F.
    Verojporn, K.
    Singh, B.
    Kiatbodin, L.
    Date, A.
    Akbarzadeh, A.
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 608 - 614