Detection of Subnanomolar Melamine Based on Electrochemical Accumulation Coupled with Enzyme Colorimetric Assay

被引:19
作者
Xu, Qin [1 ]
Wei, Huan Ping [1 ]
Du, Shi [1 ]
Li, Hong Bo [1 ,2 ]
Ji, Zhen Ping [1 ]
Hu, Xiao Ya [1 ]
机构
[1] Yangzhou Univ, Coll Chem & Chem Engn, Yangzhou 225002, Peoples R China
[2] Yancheng Inst Technol, Coll Chem & Biol Engn, Yancheng 224051, Peoples R China
关键词
melamine; subnanomolar; electrochemical; colorimetric; MILK POWDER; HORSERADISH-PEROXIDASE; LIQUID-CHROMATOGRAPHY; GUAIACOL OXIDATION; MASS-SPECTROMETRY; DAIRY-PRODUCTS; HUMAN URINE; RAW-MILK; SURFACE; ACID;
D O I
10.1021/jf304034e
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Based on the synergetic effect of the electrochemical accumulation process and the signal amplification of enzymes, a new sensitive method has been developed for the detection of subnanomolar melamine. There are two steps involved in the sensor construction process: (1) accumulation of melamine on an electrode by cyclic voltammetric method and (2) chemical coupling of horseradish peroxidase (HRP) with the accumulated melamine through the linkage of glutaraldehyde. The coupled HRP catalyzes the oxidation of guaiacol to generate an amber-colored product. Quantitative analysis of melamine is performed by measuring the absorption intensities of the colored product. Under the optimal conditions, the method showed a wide linearity in the concentration range from 1.0 x 10(-11) to 1.0 x 10(-8) M for melamine detection. Moreover, it has been successfully applied to detect melamine in different infant formula powders and fish feed samples.
引用
收藏
页码:1810 / 1817
页数:8
相关论文
共 44 条
  • [41] Preparation of Monoclonal Antibody for Melamine and Development of an Indirect Competitive ELISA for Melamine Detection in Raw Milk, Milk Powder, and Animal Feeds
    Yin, Weiwei
    Liu, Jinting
    Zhang, Taichang
    Li, Weihua
    Liu, Wei
    Meng, Meng
    He, Fangyang
    Wan, Yuping
    Feng, Caiwei
    Wang, Shanliang
    Lu, Xiao
    Xi, Rimo
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (14) : 8152 - 8157
  • [42] Pretreatment-free fast ultraviolet detection of melamine in milk products with a disposable microfluidic device
    Zhai, Chun
    Qiang, Wei
    Sheng, Jin
    Lei, Jianping
    Ju, Huangxian
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (05) : 785 - 789
  • [43] 3.3'-diaminobenzidine (DAB)-H2O2-HRP voltammetric enzyme-linked immunoassay for the detection of carcionembryonic antigen
    Zhang, Shusheng
    Yang, Jun
    Lin, Jiehua
    [J]. BIOELECTROCHEMISTRY, 2008, 72 (01) : 47 - 52
  • [44] Stripping analysis combined on-line with inductively coupled plasma-atomic emission spectrometry and with inductively coupled plasma-mass spectrometry
    Zhou, FM
    [J]. ELECTROANALYSIS, 1996, 8 (10) : 855 - 861