Steps toward percutaneous aortic valve replacement

被引:124
作者
Boudjemline, Y
Bonhoeffer, P
机构
[1] Hop Necker Enfants Malad, Serv Cardiol Pediat, Paris, France
[2] Great Ormond St Hosp Children, Cardiothorac Unit, London WC1N 3JH, England
关键词
heart disease; aorta; valves;
D O I
10.1161/hc0602.103361
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-To date, the surgical approach is the only option to replace the aortic valve. Percutaneous pulmonary valve replacement has recently opened new perspectives on transcatheter replacement of cardiac valves. We report our experience of aortic valve replacement through a percutaneous technique in lambs. Methods and Results-A bovine jugular vein containing a valve was dissected and sutured into a stent. Twelve lambs were divided into 3 groups. In the first, a valved stent was implanted in the descending aorta after creation of an aortic insufficiency. In the second, the valve was implanted in the native position. In the third, we inserted a valved stent in the native position using an orientation mechanism. All valves were successfully delivered and functioned perfectly in short-term evaluation. All experiments in group 2 failed: 1 valve obstructed the coronary artery orifices, 1 stent was responsible for a major mitral valve insufficiency, and the third implant migrated prematurely. A paraprosthetic leak occurred in the last animal in this group. Animals in group 3 had successful implantation of the valved stent. The orientation mechanism allowed perfect alignment of the device without any damage to the coronary circulation or to mural valve function. Conclusions-Nonsurgical implantation of an aortic valve is possible in lambs in the descending aorta and in the native position. An orientation mechanism is obviously needed to avoid obstruction of the coronary orifices. With further improvements, this technique should be feasible in humans.
引用
收藏
页码:775 / 778
页数:4
相关论文
共 12 条
  • [1] BASHORE TM, 1991, CIRCULATION, V84, P2383
  • [2] Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction
    Bonhoeffer, P
    Boudjemline, Y
    Saliba, Z
    Merckx, J
    Aggoun, Y
    Bonnet, D
    Acar, P
    Le Bidois, J
    Sidi, D
    Kachaner, J
    [J]. LANCET, 2000, 356 (9239) : 1403 - 1405
  • [3] Transcatheter implantation of a bovine valve in pulmonary position - A lamb study
    Bonhoeffer, P
    Boudjemline, Y
    Saliba, Z
    Hausse, AO
    Aggoun, Y
    Bonnet, D
    Sidi, D
    Kachaner, J
    [J]. CIRCULATION, 2000, 102 (07) : 813 - 816
  • [4] Bonhoeffer P, 1999, CATHETER CARDIO INTE, V48, P178, DOI 10.1002/(SICI)1522-726X(199910)48:2<178::AID-CCD11>3.0.CO
  • [5] 2-5
  • [6] Percutaneous balloon valvuloplasty for pulmonic stenosis in adolescents and adults
    Chen, CR
    Cheng, TO
    Huang, T
    Zhou, UL
    Chen, JY
    Huang, YG
    Li, HJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (01) : 21 - 25
  • [7] HUFNAGEL CA, 1954, SURGERY, V35, P673
  • [8] Late results of percutaneous mitral commissurotomy in a series of 1024 patients - Analysis of late clinical deterioration: Frequency, anatomic findings, and predictive factors
    Iung, B
    Garbarz, E
    Michaud, P
    Helou, S
    Farah, B
    Berdah, P
    Michel, PL
    Cormier, B
    Vahanian, A
    [J]. CIRCULATION, 1999, 99 (25) : 3272 - 3278
  • [9] Long-term invasive and noninvasive results of percutaneous balloon pulmonary valvuloplasty in children, adolescents, and adults
    Jarrar, M
    Betbout, F
    Farhat, MB
    Maatouk, F
    Gamra, H
    Addad, F
    Hammami, S
    Hamda, KB
    [J]. AMERICAN HEART JOURNAL, 1999, 138 (05) : 950 - 954
  • [10] PERCUTANEOUS BALLOON AORTIC VALVULOPLASTY - RESULTS IN 23 PATIENTS
    LABABIDI, Z
    WU, JR
    WALLS, JT
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (01) : 194 - 197